Produttore : AEG
File Size : 1.35 mb
File Nome : 254500EN.pdf
|
Facilità d'uso
The insulation may be damaged. • Repairs to electrical appliances should only be carried out by a trained electrician. Improperly performed repairs may place the user at serious risk. • If your vacuum cleaner has a fault, please therefore contact your electrical retailer or the AEG Service Centre direct. • Make sure that a paper dustbag and MICROFILTER are always inserted. • Never use your appliance to vacuum matches, glowing embers, or cigarette-ends. Avoid vacuuming hard pointed objects, since they may damage the appliance or paper dustbag. • Allow shampooed carpets to dry completely before vacuum cleaning. This is important as otherwise your vacuum cleaner may be damaged! • If the appliance is wrongly operated or used for a purpose other than that for which it is intended, no liability can be accepted for any possible damage. This appliance complies with the safety requirements of EEC Directive 82/499 EEC as well as with the Standard relating the Retroactive Effects of the Mains Supply EN 60 555 Parts 1-3/DIN VDE 0838 Parts 1-3, June 1987. Insert handle First of all, insert the handlegrip into the tubular handle by pressing down the locking knob, taking care that the knob comes to rest in the hole provided. Fig. 2: Insert the handle into the top of the appliance and secure it by means of the lock-nut. The handlegrip and cable clips must point backwards. Insert the electric lead into the plug aperture on the handle next to the upper cable clip. Conversion into a hand appliance (fig- 3) Detach the handle from the appliance, separate the handlegrip from the handle tube by pressing on the knob and pulling, and insert it in the appliance in place of the handle. The handlegrip of the handle tube and the handle on the appliance enable the appliance to be used with ease and comfort on upholstery, mattrasses, etc. Fig. 4: The nozzles are connected by pushing and twisting and disconnected by pulling and twisting. Switching on and off (fig. 5) Switch your vacuum cleaner on or off with the on/off button (A). If you have connected other electrical appliances with high connected load on the same circuit and switch them on simultaneously with your vacuum cleaner, the fuse may cut out. On the VAMPYRETTE 315, this can be avoided by setting the slide control to 250 W before switching on and then controlling the setting to a higher level after switching on. Power economy button and electronic suction control The VAMPYRETTE 315 incorporates a high-performance blower. The suction power can be electronically controlled by means of three settings: 250 W, E-500 W, and 750 W. Fig. 5/B: Before switching on your vacuum cleaner, preprogramme the power economy button E. The power economy button ensures that your vacuum cleaner has the right degree of suction for normal everyday cleaning tasks. Should, however, more intensive vacuum cleaning be required (removing heavy dirt stains, working on smooth floors, etc.), the degree of suction can be increased to 750 W. In exactly the same manner, the suction power can also be reduced to 250 W (for delicate fabrics, light carpets, etc.). It should basically be noted that the highest suction power setting will give the best cleaning results. With increasing wattage, however, the power consumption also increases together with the effort required to push the nozzles and the operating noise of the vacuum cleaner. All buttons can be pressed or preprogrammed in any arbitrary sequence. Filter change The filter change (bag full) indicator (fig. 1/J) tells you that the filters must be changed. You should then check as follows: Switch on vacuum cleaner and set to 750 W. If a red symbol in the inspection window shows red, the dustbag or also the MICROFILTER must be changed. Please use original AEG dustbags or MICROFILTERS provided with the quality seal. This will ensure high suction power and reliability. Replacement filters (size 20) are available from your stockist under E-No. 618 899 679 and from the AEG After-Sales Service under ET-No. 668 901 257. Damage resulting from use of other dustbags will not be covered by guarantee. Every pack of original AEG paper filters contains: 10 dustbags and 2 MICROFILTERS. Changing the filters (fig. 6) Open the dust compartment lid by depressing the snapaction catch and remove the lid. Fig. 7: The lid can be used to carry the full dustbag. Take out the full dustbag and fit the new dustbag on the dustbag carrier. Fig. 8: Please note: after every fifth dustbag change, the MICROFILTER must also be replaced to ensure proper suction power. Through timely replacement, you will ensure optimum suction power and save yourself work. Fig. 9: Insert the lid into the appliance and press it firmly closed. VARIO 1500 easy-glide nozzle with up-to-the-edge cleaning (fig. 10) It additionally features a pivot that makes your hand vacuum cleaner especially mobile. Working under furniture is eased by lateral rotation of the appliance. Fig. 11: When...