Then turn the power switch Off (O) and unplug the machine. 12 Push the machine to a designated waste water “DISPOSAL SITE” and empty the recovery tank. To empty, pull the Recovery Tank Drain Hose (12) from its rear storage hanger, then remove the plug (hold the end of the hose above the water level in the tank to avoid sudden, uncontrolled flow of waste water). Refill the solution tank and continue cleaning. USING ATTACHMENTS To use accessory tools, disconnect the recovery hose at the Recovery Hose Connection (18). Attach the accessory's recovery hose to the machine's Recovery Hose (3). Attach the accessory's solution hose to the machine's Accessory Solution Hose (2). When using accessory tools place the Extract/ Accessory Switch (23 or 25) in the accessory position (wand symbol). See your Nilfisk Distributor for accessories that may be used with the AX 410. HARD FLOOR KITS The vacuum shoe can be removed and replaced with an optional Squeegee Tool (A) for use on hard floors. See Figure 5. The vacuum shoe can be removed by pulling on the Pin Release (7) and sliding the Vacuum Shoe (8) off. Then disconnect the Recovery Hose (B) from the vacuum shoe and connect to the squeegee tool. Attach the squeegee tool to the machine at the same mounting location used for the vacuum shoe, simply pull the pin release and slide the squeegee tool into place. FIGURE 5 revised 12/10 FORM NO. 56041671 - AX 410 - B-7 B-8 / ENGLISH AFTER USING THE MACHINE 1 Turn the Power Switch OFF (O). Unplug the Power Cord (10). Coil the cord and hang it from the cord hook. 2 To empty the solution tank, pull the Solution Drain Hose (15) off the elbow. Direct the hose to a designated waste water “DISPOSAL SITE”. Rinse the tank with clean water. Inspect the solution hoses; replace if kinked or damaged. 3 To empty the recovery tank, take the Recovery Drain Hose (12) off its hanger. Direct the hose to a designated waste water “DISPOSAL SITE” and remove the plug (hold the end of the hose above the water level in the tank to avoid sudden, uncontrolled flow of waste water). Rinse the tank with clean water. Inspect the recovery and drain hoses; replace if kinked or damaged. 4 Remove the brush, rinse with warm water and remove any built-up string, hair or carpet fibers. 5 Disconnect the Recovery Hose (3) from the Recovery Tank Dome Lid (4) and flush with warm water to wash any debris out of the Recovery Hose and Vacuum Shoe. 6 Wipe the machine with a damp cloth. Do not use abrasive chemicals or solvents. 7 Perform any required maintenance before storage. MAINTENANCE SCHEDULE MAINTENANCE ITEM_Daily_Weekly_Yearly Check / Clean Power Brush • Check / Clean Tanks & Hoses • Check / Clean Vacuum Shut-Off Float • Clean Vacuum Shoe • Clean “Maintenance” Spray Nozzle • Inspect & Clean Solution Screen • *Check Carbon Brushes • * Have a Nilfisk service technician check the vacuum motor carbon brushes once a year or after 300 operating hours. The brush motor carbon brushes check every 500 hours or once a year. A IMPORTANT! Motor damage resulting from failure to service the carbon brushes is not covered under warranty. See the Limited Warranty Statement. 8 Store the machine indoors in a clean, dry place with the tank dome lid open. Keep from freezing. 9 Place the machine in the storage position. This will prevent the brush from taking a set which will increase the brush life and maintain the performance of the brush. Lift up on the Handle Release Pedal (16) then push the Handle Assembly (19A) forward to place the machine in the storage position. VACUUM SHOE MAINTENANCE Check the vacuum shoe daily. Remove any built-up string, hair or carpet fibers. See Figure 6. The vacuum shoe can be removed by pulling on the Pin Release (7) and sliding the Vacuum Shoe (8) off. Then disconnect the recovery hose from the shoe. FIGURE 6 B-8 - FORM NO. 56041671 - AX 410 revised 12/08 ENGLISH / B-9 SPRAY NOZZLE MAINTENANCE Remove the Maintenance Spray Nozzle (C) once a week. See Figure 7. Soak the nozzle overnight in vinegar to remove chemical deposits. SOLUTION SCREEN MAINTENANCE Once a week (or more often if necessary), clean the Solution Screen (13). Drain the solution and recovery tanks. Lift the recovery tank from the machine and set it off to the side. Reach inside the solution tank and unthread the solution filter to remove. POWER CORD MAINTENANCE Once a week (or more often if necessary), check the power cord for cracked or damaged insulation, exposed wires in the cord or plug, and damaged or missing ground pin. Repair or replace damaged cord or plug immediately. ADJUSTING THE BRUSH PRESSURE Simply turn the Brush Pressure Adjustment Knob (19) clockwise to increase brush pressure and counter-clockwise to decrease the brush pressure. POWER BRUSH MAINTENANCE Check the brush daily. Remove any built-up string, hair or carpet fibers. When the machine is not in use it should be placed in the storage position. This will pre...
Questo manuale è adatto anche per i modelli :Aspirapolvere - 56265002 (1.11 mb)