Log:
valutazioni - 3, GPA: 4.3 ( )

Istruzioni per l'uso Panasonic, Modello MCV6950

Produttore : Panasonic
File Size : 1003.89 kb
File Nome : MCV6950.PDF
Lingua di insegnamento: en
Vai a scaricare



Facilità d'uso


The belt tension is high. Failure to do so could result in personal injury from agitator brush assembly releasing quickly and snapping away. Unplug and turn the unit over. Remove the lower plate as described in the Removing/Installing the Lower Plate section. Remove the agitator brush assembly (carefully lift it out), and remove the worn or broken belt from the agitator pulley and motor drive shaft. Loop the new belt around the motor drive shaft and then loop it around the agitator pulley. Use only a Panasonic Type UB drive belt. Before reinserting the agitator brush assembly make sure that the end caps are on correctly. (See the illustration in the Replacing the Agitator Assembly section.) End Cap Reinstall Agitator After checking the end caps, reinstall the agitator brush assembly back into the housing grooves. After installing the agitator brush assembly, turn it by hand making sure that the belt is not twisted and all rotating parts turn freely. Replace the lower plate as described in the Removing/Installing the Lower Plate section. Switch off the vacuum cleaner and unplug the power cord before cleaning the agitator assembly. In order to keep the cleaning efficiency high, clean the agitator assembly regularly. Remove the lower plate if necessary. See the Removing/Installing the Lower Plate section for the proper procedure. Agitator assembly - Cut off any carpet pile and lint entangled around the agitator assembly with a pair of scissors as illustrated. - 14- A WARNING Electrical Shock or Personal Injury Hazard. Disconnect the electrical supply before servicing or cleaning the unit. Failure to do so could result in electrical shock or personal injury from the cleaner suddenly starting AOKTAXrtO ACCCklD! V 1 When to replace the agitator assembly The agitator assembly should be replaced when the brushes are worn Brushes should be checked by holding a card across the bottom plate (see illustration) If the bristles on the agitator assembly do not touch the card you should replace the agitator assembly for best cleaning results 2 How to replace the agitator assembly. Place the vacuum cleaner handle in the low position (See the Handle Adjustments section ) Remove the lower plate as outlined in the Removing/Installing the Lower Plate section After the lower plate is removed, carefully lift up the agitator assembly until it clears both sides of the nozzle housing While holding the agitator assembly up, remove the belt CAUTION The two end caps may come off along with the two washers as you lift the agitator assembly out Do not lose the two small washers Look at the exploded view of the agitator assembly below for correct assembly of the parts 3 To replace the agitator assembly Place the belt over the belt pulley on the agitator unit (NOTE There is a place for the belt to fit on one end of the agitator assembly only) Replace both washers and end caps (see illustration below for correct assembly) After assembling the belt, washers and end caps place the agitator assembly back into the nozzle housing by aligning each end cap After completing the assembly, rotate the brush, turning it by hand to assure that it rotates smoothly and the part is assembled correctly Replace the lower plate as outlined in the Removing/Installing the Lower Plate section - 15 - CLEANING EXTERIOR AND ATTACHMENTS 1 Unplug cord from wait outlet DO NOT drip water on cleaner 2 Clean exterior using a clean, soft cloth that has been dipped in a solution of mild liquid detergent and water, then wrung dry Wipe dry after cleaning 3 To reduce static electricity and dust build-up, wipe outer surface of cleaner and attachments 4 Wash attachments in warm soapy water, nnse and air dry Do not clean in dishwasher or clothes washer DO NOT USE ATTACHMENTS IF THEY ARE WET A CAUTION Attachments used in dirty areas (such as under a refrigerator) should not be used on other surfaces until they are washed They could leave marks. REMOVING CLOGS A WARNING Electric Shock or Personal Injury Hazard Disconnect electncal supply before servicing or cleaning the unit Failure to do so could result m electrical shock or personal injury from the cleaner suddenly starting For best cleaning results, keep the airflow passages clear Unplug the power cord from the outlet before checking the airflow passage Check each starred area occasionally for clogs Disconnect the wand from the short hose and check the wand and hoses for clogging Plug in the vacuum cleaner and turn it on While running the vacuum cleaner with the hose disconnected, stretch the hose in and out to remove the clog Pull down on the suction inlet cover and check for clogging in this area If the clog still exists, turn the vacuum OFF and unplug the power cord Turn the cleaner over, exposing the underside Remove the lower plate Remove the short nozzle hose from the housing by lifting it straight up Inspect the hose end and clear it of any obstructions Reinstall the short noz...


Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie