Log:
valutazioni - , GPA: ( )

Istruzioni per l'uso Bosch, Modello AS3016/01

Produttore : Bosch
File Size : 1.16 mb
File Nome :

Lingua di insegnamento: ruenesfrdebghuptcsro

Il documento viene caricato, si prega di attendere
Il documento viene caricato, si prega di attendere

Facilità d'uso


Opening the flap reduces suction, whereas closing it increases suction, figure 8. WHEN FINISHED When you have finished using the applian ce press the On/Off switch. Press the automatic cable rewind pedal (9) to wind the cable back in, figure 9. CONTAINER FULL INDICATOR When suction power decreases considerably and the full indicator (14) lights up, this means that the container is full or that the hose is blocked. If this occurs do as described in the next point: MAINTAINING THE CYCLE-TECH UNIT Empting the container The container must be emptied after each use. To do this, press the release button (12) and remove the container, Figure 10. Empty the contents into a dustbin by pressing button (24) to open the base flap (25), figure 11. Bring the flap (25) back up to close it again. Locking it back on to the base of the container. Place the container back into its housing on the vacuum cleaner. Cleaning the filters It is advisable to clean the permanent HEPA filter at least every six uses and to replace the air outlet filter each year. The filters must always be cleaned whenever any type of blockage occurs with the suction. Cleaning the permanent HEPA filter: Open the container lid (19), Figure 12. Turn the HEPA filter (21) anti-clockwise to remove it and pull it out of its housing, Figure 13. Pull off the filter cover (22) which is just pressed on to the HEPA filter, Figure 14. The filter can be hand washed with water and a mild detergent. Once the HEPA filter is cleaned and dried, push the filter cover back on and fit the assembly back into its housing by turning it clockwise until it locks into position. Close the lid (19). Fit the container back into its housing on the vacuum cleaner, Figure 15. IMPORTANT: Leave the HEPA filter to dr y for 24 hours before refitting it. Replacing the air inlet and outlet filters Remove the air outlet grille (10) by pressing the release clips down and rocking it off gently, Figure 16. Extract the filter support and remove the filter, Figure 17. To remove the air inlet filter (23), open the container lid (19), Figure 12. Remove the filter attached to the inside of the lid, Figure 18. Ufesa recommends that the permanent HEPA filter and air outlet filter (11) and air inlet filter (23) be replaced yearly (depending on use). You can get these replacements at your local shopping centre or from an Authorised Dealer. Important: The vacuum cleaner must ne ver be switched on unless these filters are fitted correctly. To guarantee trouble-free operation, use only original Ufesa parts. GENERAL PURPOSE FLOOR BRUSH Model: AS3016 The general purpose floor brush supplied with this model has two different sweeping positions. If we press the button on the brush to the [ ] position the bristles at the front of the brush come out which, together with the two rear wheels, makes it easier to move across all types of surfaces, Figure 19. If we press the button on the brush to the [ ] position the bristles at the front of the brush retract to produce more efficient suction on carpets and rugs, Figure 20. Model AS3018 The general purpose floor brush supplied with this model has 6 wheels, making it easier to travel across all types of surfaces. BRUSH FOR WOODEN FLOORING (AS3018) This brush has been specially designed to clean wooden floor surfaces. The soft hair bristles brush over the surface picking up the dust but without damaging the floor. AS3016/18.indd 9 23/6/06 14:04:1 ACCESSORY FOR CLEANING FURNITURE This accessory is ideal for vacuum cleaning furniture and other delicate surfaces. UPHOLSTERY ACCESSORY This accessory has been designed to clean all types of upholstery. ACCESSORY FOR CLEANING CREVICES Use this accessory to vacuum crevices and other awkward surfaces. REPLACEMENTS To guarantee trouble free operation, only use original Ufesa filters which can be found at authorised establishments, reference n.: FA0300. The accessor y pack contains a permanent HEPA filter, one air outlet filter and an air inlet filter. CLEANING Unplug the vacuum from the mains supply before cleaning it. The accessories and the vacuum can be wiped clean with a damp cloth and then left to dry before reusing them. Never immerse the appliance in water. Do not use solvents nor abrasive products to clean it. ADVICE ON DISPOSAL: Our goods come in optimised packaging. This basically consists in using non-contaminating materials which should be handed over to the local waste disposal ser vice as secondary raw materials. This product complies with EU Directive 2002/96/CE. The crossed wheelie bin symbol shown on the appliance indicates that when it comes to dispose of the product it must not be included in with household refuse. It must be taken to a special refuse collection point for electric and electronic appliances or returned to the distributor when purchasing a similar appliance. Und...

Questo manuale è adatto anche per i modelli :
Aspirapolvere - AS3018/01 (1.16 mb)

Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie