|
Facilità d'uso
Exit Any Menu Field Operation Or Display Press Cancel as many times as required to return to the desired menu level or press Home to return to the main menu. 3-8 TSU 600 User Manual 61202076L1-1 Chapter 3. Operation Data Port Identification When configuring the unit, menu selections will include options from data port submenus. Selecting of data ports is necessary because the TSU 600 uses a Slot-Port method to identify which data port the menu item is referencing. If a module containing a PBX DSX-1 option card with an Nx56/64 plug-on interface is installed in option slot 6, it would be designated as: DSX-1 Passthru=6.1 Where slot=6 and port =1. The DSX-1 is located in option slot 6 and is the first port in that slot. Nx56/64=6.2 Where slot=6 and port=2. The Nx is located in Slot 6 and is the second port in that slot. Viewed from the rear of the TSU 600, the module slots are arranged as shown in Figure 3-4. POWER SUPPLYSLOT 1 SLOT 4 SLOT 2 SLOT 5 SLOT 3 SLOT 6 Figure 3-4. Module Slots, TSU 600 61202076L1-1 TSU 600 User Manual Chapter 3. Operation Front Panel Menu Structure The TSU 600 uses a multilevel menu structure containing both menu items and data fields. All menu operations and data display in the LCD window. The opening menu is the access point to all other operations. Each Main Menu item has several functions and submenus to identify and access specific parameters. The front panel LCD of the Main Menu contains the following options: Option Description Status Displays all relevant information for the network and DTE interfaces. For detailed information on status options, see Chapter 4, Status Menu. Config (Configuration) Displays and sets the TSU 600 operational configuration, including all network interface parameters, the allocation of the DS0s, and the port parameters. For detailed information on configuration options, see Chapter 5, Configuration Menu. Util (Utilities) Displays and sets system parameters. For detailed information on utility options, see Chapter 6, Utility Menu. Test The Test menu initiates different types of unit tests and displays test results in the LCD window. For detailed information on test options, see Chapter 7, Test Menu. 3-10 TSU 600 User Manual 61202076L1-1 Chapter 3. Operation Alternate Methods of Control T-Watch PRO (ADTRAN PC Program) T-Watch PRO is the ADTRAN PC control program. It provides complete control over the configuration of the TSU 600 using a graphical interface and displays the same status and performance data as the front panel LCD. This data is displayed in the form of tables and graphs. The T-Watch PRO program has the following capabilities: • Interfaces with a modem which permits dialing into a remote TSU 600 location to configure the unit or read the status or performance of the unit. • Receives traps from any TSU product. • Records and creates display performance data over a 30 day period. • Accesses units via the local area network. T-Watch PRO/LAN Connection To set up the TSU 600 to work with T-Watch PRO over the LAN, follow these steps: Step Action 1 Set the Unit ID using the Front Panel. See Unit ID on page 6-3 for more information. 2 Set Control Port to SLIP or Normal for 10BaseT (600e only) using the Front Panel. 3 Configure the IP address default gateway, and sub- net mask using the Front Panel. The default gateway and subnet masks are not used for SLIP mode. 4 Follow the installation instructions for T-Watch PRO to start the program and connect to the unit. 61202076L1-1 TSU 600 User Manual Chapter 3. Operation T-Watch PRO/EIA-232 Connection To set up the TSU 600 to work with T-Watch PRO over a direct EIA-232 connection, the following steps are required: Step Action 1 Set the Unit ID and the Passcode using the Front Panel. See Unit ID on page 6-3 and Change/Set a Passcode on page 6-3 for more details. 2 Set the Control Port rate to the same setting as the PC Com port. 3 Connect the PC Com port to the Chain-In port on the TSU 600 using the DB25 to modular adapter and 6-foot modular cable. 4 Follow the installation instructions for T-Watch PRO to start the program and connect to the unit. SNMP The ADTRAN TSU 600 supports the Simple Network Management Protocol (SNMP) through the chain-in (SLIP) interface or 10BaseT interface (600e only). See Appendix B, Understanding SNMP for detailed information. To use SNMP with the TSU 600, do the following: Step Action 1 Set Control Port to SLIP for Chain-In Port or Normal for 10BaseT (600e only). 2 Set the IP address, default gateway, and subnet mask through the front panel. The default gateway and subnet mask are not used in SLIP mode. 3 Load the appropriate MIB browser into the Network Management Station (available on the ADTRAN webpage at com). The MIB browser issues SNMP gets/sets to the TSU 600. 3-12 TSU 600 User Manual 61202076L1-1 Chapter 3. Operation Terminal Mode Connection The TSU 600 provides the front panel menus to a VT-100 type terminal. This mode can be used to configure and...
Questo manuale è adatto anche per i modelli :Telefoni cordless - 1202076L2 (687.09 kb)