Log:
valutazioni - 3, GPA: 4 ( )

Istruzioni per l'uso Graco Inc., Modello 1095 Premium Hi

Produttore : Graco Inc.
File Size : 2.76 mb
File Nome : ee096b35-2384-4c29-945f-649282e43489.pdf
Lingua di insegnamento: en
Vai a scaricare



Facilità d'uso


If plug will not fit in outlet, have grounded outlet installed by a qualified electrician. Do not use an adapter. Power Requirements • 100-120V units require 100-120 VAC, 50/60 Hz, 15A, 1 phase. • 230V units require 230 VAC, 50/60 HZ, 10A, 1 phase. Extension Cord Use an extension cord with an undamaged ground contact. If an extension cord is necessary, use a 3-wire, 12 AWG (2.5 mm2) minimum. Pails Solvent and oil/based fluids: follow local code. Use only conductive metal pails, placed on a grounded surface such as concrete. Do not place pail on a nonconductive surface such as paper or cardboard which interrupts grounding continuity. Grounding a metal pail: connect a ground wire to the pail by clamping one end to pail and other end to a true earth ground. To maintain grounding continuity when flushing or relieving pressure: hold metal part of spray gun firmly to side of a grounded metal pail. Then trigger gun. ti4297a ti2810a Ground 120 volt plug ti5850a ti14840a ti13243a 15/20 Amp Switch (Not Available on All Units) 8 3A0156A 15/20 Amp Switch (Not Available on All Units) Select 15A or 20A setting based on your circuit rating. Pressure Relief Procedure 1. Turn power OFF. Wait 7 seconds for power to dissipate. 2. Lock gun trigger safety. Remove guard and SwitchTip. 3. Turn pressure to lowest setting. Trigger gun to relieve pressure. 4. Put drain tube in pail. Turn prime valve down to DRAIN position. 20 ti14919a ti4265a ti10166a ti2769a - ti14841a ti2595a ti14842a Setup 3A0156A 9 Setup 1. Standard Units Only: Connect Graco airless hose to sprayer. Tighten securely. 2. Standard Units Only: Connect other end of hose to gun and tighten securely. 3. Engage gun trigger safety. 4. Remove tip guard. 5. Check inlet strainer for clogs and debris. 6. Fill throat packing nut with Graco TSL to prevent premature packing wear. Do this each time you spray. 7. Turn power OFF. 8. Plug power supply cord into a properly grounded electrical outlet. 9. Turn prime valve down to DRAIN position. 10. Place pump in grounded metal pail partially filled with flushing fluid. Attach ground wire to pail and to true earth ground. Perform steps 1 - 5 of Startup to flush out storage oil shipped in sprayer. Use water to flush water-base paint and mineral spirits to flush oil-base paint and storage oil. ti14843a ti13031a ti10166a ti2769a ti13453a ti4265a ti4265a ti2810a ti14842a ti14844a Startup 10 3A0156A Startup 1. Turn pressure control to lowest pressure. 2. Turn power ON. 3. Increase pressure 1/2 turn to start motor and allow fluid to circulate through drain tube for 15 seconds; turn pressure down. 4. Turn prime valve forward to SPRAY position. Disengage gun trigger safety. 5. Hold gun against grounded metal flushing pail. Trigger gun and increase fluid pressure 1/2 turn. Flush 1 minute. 6. Inspect for leaks. Do not stop leaks with hand or a rag! If leaks occur, perform Pressure Relief Procedure, page 8. Tighten fittings. Perform Startup, steps 1 - 5. If no leaks, proceed to step 7. 7. Place pump in paint pail. 8. Trigger gun again into flushing pail until paint appears. Move gun to paint pail and trigger for 20 seconds. Set gun safety ON. Assemble tip and guard, see instructions on next page. ti4266a ti4266a 1/2 15sec. ti14845a ti10167a ti4271a 1/2 ti13243a PAINT ti2714a ti13029a ti10166a Switch Tip Installation 3A0156A 11 Switch Tip Installation 1. Use spray tip (A) to insert OneSeal™ (B) into guard (C). 2. Insert Switch Tip. 3. Screw assembly onto gun. Tighten. Spray 1. Spray test pattern. Increase pressure to eliminate heavy edges. Use smaller tip size if pressure adjustment can not eliminate heavy edges. 2. Hold gun perpendicular, 10-12 in. (25-30 cm) from surface. Spray back and forth. Overlap by 50%. Trigger gun after moving and release before stopping. Clearing Tip Clog 1. Release trigger, put safety ON. Rotate SwitchTip. Take safety OFF. Trigger gun to clear clog. Never point gun at your hand or into a rag! 2. Put safety ON. Return SwitchTip to original position. Take safety OFF and continue spraying. ti13023a C B A ti13024a ti2710a ti13030a ti13025a ti10166a ti13033a ti10167a ti10166a ti13034a ti10167a WatchDog™ Protection System (Not Available on All Units) WatchDog™ Protection System (Not Available on All Units) Pump stops automatically when material pail is empty. To Activate: 1. Perform Startup. ti7398a 2. Premium units with digital display: Turn WatchDog switch ON and WD ON displays. EMPTY displays/flashes and pump stops when Watchdog protection system detects an empty material pail. ti6224a 3. Turn WatchDog switch OFF. Add material or reprime sprayer. Turn pump switch OFF and ON to reset WatchDog protection system. Turn WatchDog switch back ON to continue to monitor material level. ti7399a ............A Fast Flush To flush the hose and gun at an accelerated speed, perform the following steps: 1. Perform steps 1 -3 of Cleanup, page 16. 2. Hold gun trigger in and turn prime valve down to DRAIN position and then over to FAST FLU...

Questo manuale è adatto anche per i modelli :
Pistole - 1595 Premium Hi (2.76 mb)

Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie