The spray applicator should be thoroughly cleaned after each use. Follow the cleaning instructions on page 9 with reference to the drawings on page 3 ! Check the needle and fluid tip on a regular basis for excessive wear, and replace as necessary. See the cleaning instructions for the correct procedure for removing these parts. Replacement needle sets are available from Earlex Ltd. ! Keep all moving parts lubricated with a light smear of petroleum jelly. ! Lubricate the gland washer, after each time you clean it, with a light smear of petroleum jelly. ! Check there is no leakage from the gland washer. If there is, tighten the gland nut a little to ensure a seal with the needle. Do not over-tighten this nut, also ensure the gland washer has not dried out. If it has, lubricate it as above. TURBINE UNIT ! Check the condition of the filters that are housed in the front cover. This is easily removed by sliding it upwards. If clogged, remove and blow out using an airline, or wash out using a mild detergent if necessary. ! Keep the outer surface of the air hose free from harmful substances such as petrol, automotive coating thinners, paint strippers & oil. Prolonged exposure to such substances may cause irreparable damage. Always check and clean off any excess immediately. ! Check the condition of the power cord regularly. If there are any cuts or serious abrasions to the outer sheath, replace it immediately. When the unit is not in use, keep the power cord coiled around the brackets at the back of the turbine case. When the unit is being used, protect the power cord and any extension cord from damage that could be caused, for example, by traffic or hazardous substances. The turbine unit can only be fully serviced by authorised service agents. 10 TROUBLESHOOTING PROBLEM CAUSE ACTION REQUIRED The paint runsor sags? Paint too diluted Add undiluted material Paint volume too high Reduce the paint flow by turning Fluid Adjusting Screw Moving too slowly Increase speed of application Spray gun trigger being held for too long Release trigger earlier Spray gun too close Increase the distance between gun and workpiece Paint is thin or irregular Paint too thick Add thinner Paint volume too low Increase the paint flow by turning Fluid Adjusting Screw Moving too fast Reduce speed of application Spray gun clogged Clean the gun Spray gun too far away Reduce the distance between gun and work piece No spray pattern being produced Air Volume too low Set air volume control valve to max by turning anti-clockwise Paint too thick Add thinner Gun clogged Clean the spray gun Pick up pipe clogged Clean Paint Feed Tube Air hose split Replace air hose Gritty paint Filter the paint Container almost empty Refill container Spray gun at an angle Ensure Paint Feed Tube is angled towards paint Air intake blocked Check the condition of the Filter and clean as neccessary Unit will not start Circuit breaker tripped (HV7000 unit) Check the back of the unit. If the circuit breaker has tripped, a white push button cator will appear. Push in to reset.indi em, pleaselIf this does not cure the prob refer to your nearest service agent. House circuit breaker Check and reset if required. 11 MAINS CONNECTION 230V UK ONLY The Spray Port is supplied fitted with a 13 amp plug and fuse. If a replacement fuse is required this must be rated at 13 amps. If in doubt consult an electrician. WARNING -THIS APPLIANCE MUST BE EARTHED. If any eletrical component is damaged or faulty, it must be replaced by the manufacturer or its appointed service agent or a similarly qualified person in order to avoid a hazard. As the colours of the wires in the mains lead of this appliance may not correspond with the coloured markings identifying the terminals in your plug, proceed as follows: ! The wire which is coloured green and yellow must be connected to the terminal in the plug which is marked with the letter E or by the earth symbol, or coloured green or green and yellow. ! The wire which is coloured blue must be connected to the terminal which is marked with the letter N or coloured black. ! The wire which is coloured brown must be connected to the terminal which is marked with the letter L or coloured red. MAINS CONNECTION 110V UK ONLY The unit is fitted with a 16 amp industrial plug for insertion into a suitable transformer or generator supplying 110V a.c. outlet. If this mains cable becomes damaged it must be replaced by the manufacturer or its appointed service agent or a similarly qualified person in order to avoid a hazard. Copyright & Design Right Reserved © 2010 HV7000 Patent -GB 2429179 Gun (Type A) Design Registration -GB 3006933 EC Declaration of Conformity We declare that the unit: HV7000 Conforms to LVD 2006/95/EC, EN60335-1, EMC 2004/108/EC, EN55014-1, EN61000-3-2, EN61000-3-3. Tim Hopper Technical Director GUARANTEE This product is guaranteed for a period of 12 months for ordinary use and 6 months for hire purposes or where the unit is lent to other users.The guara...


Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie