Log:
valutazioni - 1, GPA: 5 ( )

Istruzioni per l'uso B&B Electronics, Modello RS-232 to J1939 Converter CE 1939STB

Produttore : B&B Electronics
File Size : 471 kb
File Nome : m1939stb.pdf
Lingua di insegnamento: en
Vai a scaricare



Facilità d'uso


Inc. 707 Dayton Road --P.O. Box 1040 --Ottawa, IL 61350 USA Phone (815) 433-5100 -- General Fax (815) 433-5105 Home Page: Sales e-mail: orders@bb-elec.com --Fax (815) 433-5109 Technical Support e-mail: support@bb-elec.com --Fax (815) 433-5104 European Headquarters B&B Electronics Ltd. Westlink Commercial Park, Oranmore, Co. Galway, Ireland Phone +353 91 792444 --Fax +353 91 792445 Home Page: Sales e-mail: orders@bb-europe.com Technical Support e-mail: support@bb-europe.com . B&B Electronics – November 2000 1939STB4600 Manual Cover Page B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 B&B Electronics Ltd – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 Table of Contents INTRODUCTION ......................................................................................1 SAE Publications..................................................................................1 WARNING!................................................................................2 DESCRIPTION.............................................................................................3 Physical Description ............................................................................4 Electrical Specification ........................................................................4 Communication directed to the device .................................................5 Control Byte 3 ............................................................................................. 6 Control Byte 4 ............................................................................................. 7 Internal Functions................................................................................8 Vendor String .............................................................................................. 8 RS-232 Baud Change .................................................................................. 9 External Commands ...........................................................................13 Message Header Setup............................................................................... 14 Message Information ................................................................................. 15 Byte 5 ........................................................................................................ 16 Byte 6 ........................................................................................................ 17 Byte 11 ...................................................................................................... 18 SAE-J1939 CONTROL HEADER..........................................................19 BYTE 7....................................................................................................21 BYTE 8....................................................................................................23 BYTES 9 AND 10......................................................................................25 BYTE 11..................................................................................................26 Data Field .................................................................................................. 28 Reception of Data ...................................................................................... 29 SAE-J1939 BUS......................................................................................29 INTERNAL MESSAGES ........................................................................31 SOFTWARE .............................................................................................32 Installation................................................................................................. 32 Message Transmission............................................................................... 34 Message Reception .................................................................................... 34 Saving Message Information .................................................................... 35 File Logging ............................................................................................... 35 APPENDIX A: EXTENDED CAN/SAE-J1939 MESSAGE FRAMEA-1 APPENDIX B: EXAMPLE....................................................................B-1 1939STB4600 Manual Table of Contents B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 B&B Electronics Ltd – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91 792444 – Fax +353 91 792445 Introduction SAE-J1939 is a communication protocol developed by SAE (Society of Automotive Engineers). The communication protocol is based on the CAN specification developed by Bosch 2.0 part B (September, 1991). Before using the Model 1939STB the user should be familiar with the SAE publications listed below, and follow all the gui...


Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie