Log:
valutazioni - , GPA: ( )

Istruzioni per l'uso Axor, Modello Pharo Skyline 26017XX1

Produttore : Axor
File Size : 3.14 mb
File Nome : prgh0184.pdf

Lingua di insegnamento: en

Il documento viene caricato, si prega di attendere
Il documento viene caricato, si prega di attendere

Facilità d'uso


Protection against back siphonage provided by check valves. The check valves should be removed and inspected yearly (see page 8). This panel may be used with an instantaneous water heater if the heater is at least 24 kW and the output is at least 3 gpm @ 30 psi pressure. However, only one panel function may be used at a time. *Please know and follow all applicable local plumbing codes when setting the temperature on the water heater. In Massachusetts, the water heater may be set no higher than 112..F. showerhead neck spray handshower bodysprays foot rest User Instructions Turn the top volume control clockwise to obtain water from the overhead shower. Turn the top volume control counter-clockwise to obtain water from the neck spray. It is not possible to run the overhead shower and the neck spray simultaneously. Turn the bottom volume control clockwise to obtain water from the handshower. Turn the bottom volume control counter-clockwise to obtain water from the bodysprays. It is not possible to run the handshower and bodysprays simultaneously. The following combinations may be used by turning on each function with the volume control: Overhead shower and handshower Overhead shower and bodysprays Neck spray and handshower Neck spray and bodysprays Using the thermostatic mixer Turn the thermostatic mixer handle clockwise to make the water cooler. Turn it counter-clockwise to make it warmer. The handle will stop at the 100° safety stop. To override the safety stop, press the override button and continue turning the handle counter-clockwise. Open the overhead shower and neck spray To open the overhead shower and neck spray, press the lower left hand corner of the cover. To open the footrest, press the upper left corner of the cover. The showerhead will open to the 95° position. Push it upward to the 110° position, if desired. Adjust the showerhead cover If the showerhead or neckspray cover does not hang straight, loosen or tighten the set screw with a 3 mm Allen wrench to correct. 3 mm 3 mm Cleaning the hand and overhead showers The handshower and overhead shower use the RubitTM self-cleaning system. If scale deposits are noticed in the spray channels, turn the water on lightly and rub over the channels with a finger or a sponge to dislodge them. Troubleshooting Problem Possible cause Solution Outputs both hot and cold water, but no mix Not a product defect Supply lines connected to the incorrect elbows Reconnect supply lines to correct elbows Insufficient water Filters inside supply elbows clogged Remove and clean filters Erratic water temperature Thermostatic mixer cartridge faulty Replace thermostat cartridge Function drips, won’t shut off completely Volume control cartridge faulty Replace volume control cartridge Hot water bleeds over into cold water supply in house or vice- versa Faulty check valve Remove and clean check valve, replace if necessary Maintenance Note: The check valves located in the hot and cold elbows should be removed and inspected yearly. If the flow of water decreases over time, clean the filters. filter check valve 98877000 98876000 Replacement Parts 98881001 98875XX0 98900001 98879000 98882001 98878000 98884000 28532XX1 98901001 28276XX0 98880000 94074000 98891XX0 97582000 98891XX0 97342XX0 96509000 97441XX0 96483XX0 96519XX1 95041000 98743000 94282000 98742XX0 98883000 94082000 98884000 98874XX0 XX = color 00 = chrome 82 = brushed nickel 98744000 Cleaning Recommendation for Hansgrohe Products Modern lavatory faucets, kitchen faucets and showers consist of very different materials to comply with the needs of the market with regard to design and functionality. To avoid damage and returns, it is necessary to consider certain criteria when cleaning. When cleaning fittings and showers, keep the following in mind: • Only use cleaning materials intended for this purpose. • Never use cleaning materials which contain hydrochloric acid, formic acid, chlorine pale lye or acetic acid, as they cause considerable damage. • Phosphoric acidic cleaners are only conditionally applicable. • Do not mix cleaning products, unless instructed to do so by the cleaning material manufacturer. • Never use cleaning materials or appliances with an abrasive effect, such as unsuitable cleaning powders, sponge pads, or micro fiber cloths. • Always follow the instructions provided by the manufacturer of the cleaning product. • Be sure to use the correct amount of cleaner, and leave it in contact with the fitting for the correct amount of time. • The buildup of limescale and hard water spots should be prevented by regular cleaning. • When using spray cleaners, spray first onto a soft cloth or sponge; never directly onto the fitting, as drops could enter openings and gaps and cause damage. • After cleaning, rinse the fitting thoroughly with clean water to remove any cleaner residue. • The use of steam cleaners is not permitted. The high temperatures can damage fittings. Important Residues of liquid soaps, shampoos and sho...

Questo manuale è adatto anche per i modelli :
Plumbing - Pharo Skyline 26017XX1 (3.14 mb)
Plumbing - Pharo Skyline 26017XX1 (3.14 mb)
Plumbing - Pharo Skyline 26017XX1 (3.14 mb)

Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie