Log:
valutazioni - 4, GPA: 4.3 ( )

Istruzioni per l'uso American Standard, Modello ShowerArc 26396001

Produttore : American Standard
File Size : 4.86 mb
File Nome : hruh0109.pdf
Lingua di insegnamento: en
Vai a scaricare



Facilità d'uso


Failure to seal the wall can lead to possible water damage. 9 10 11 12 2 Seal the wall around the anchors with waterproof sealant. Failure to seal the wall can lead to possible water damage. Be careful not to drill into water lines! 6 mm 1 13 14 Install the 26397000 mounting set 16 15 17 18 XX90XX= 20 19 22 21 1 2 6 mm SW 3 mmM6x8 24 23 M6x601.2.3. SW 3 mmM6x8 25 26 Install the 26397000 mounting set 27 28 2 Seal the wall around the anchors with waterproof sealant. Failure to seal the wall can lead to possible water damage. 1 6 mm Turn to page 22 to continue the installation. SW 3 mmM6x8 29 Install the Cover, Escutcheon, and Handle 2 1 Install the Showerhead and Handshower Reset the High Temperature Limit Stop Loosen the handle screw with a 3 mm Allen wrench. Remove the retainer clip and stop ring from the stem. Turn the stop unit to the handshower position. Turn the temperature control stem until the output water is the desired high temperature -- usually 110.. 1 2 KLICK 3 4 Turn the stop unit to the off position. Install the stop ring so that the tooth is against the stop. Install the clip. Install the handle. Tighten the handle screw with a 3 mm Allen wrench. KLICK 5 6 SW 3 mm 7 Justify the Handle Turn the diverter handle to the handshower position. Turn the temperature control knob until the output water is 100.F. Turn the diverter handle to the off position. Loosen the handle screw with a 3 mm Allen wrench. Remove the handle. Align the indexing mark on the temperature control knob with the 100. mark. Replace the handle. Tighten the handle screw. 1 2 3 4 User Instructions Turn the temperature control knob to change the temperature. Turn it clockwise to make the water cooler, counter-clockwise to make the water warmer. When the knob is turned counter-clockwise to the 100. position it will stop. To obtain water hotter than 100., push the knob in, and continue turning it counter-clockwise. Turn the diverter handle to select the handshower, bodysprays, or showerhead. If the indicator on the handle is positioned between the showerhead and bodyspray positions, water will come from both. Using the Handshower Turn the function lever to until the desired spray mode has been obtained. function lever Cleaning the Handshower The handshower uses the Rubit™ cleaning system. If scale deposits are noticed in the spray channels, rub across the channels with a finger or a sponge to dislodge them. If necessary, pour about 3/4” of a commercial scale remover, such as Lime-Away or CLR, into a shallow dish. Soak the spray face for the amount of time shown in the label instructions. Rinse the spray face with clear water. Reinstall the handshower. Flush the handshower for at least one minute before using. Replacement Parts 19 9 3 1 2 20 25 23 6 7 26 15 8 17 14 22 11 16 13 17 18 12 24 21 10 5 4 25 1 wall flange 96768000 2 escutcheon 96767000 3 branch connection 97496000 4 branch connection 97497000 5 shower hose 28276000 6 handshower 28504001 7 handshower holder 28321000 8 body spray 97603000 9 showerhead 97195001 10 handle 25971000 11 shutoff unit with selector 97976000 12 escutcheon 97491000 13 thermostat cartridge 94282000 14 noise reducer 94073000 15 ball s-union 96742001 16 rear panel 97493000 17 cover 97494000 18 sleeve nut 97492000 19 pipe elbow 97495000 20 pipe 97499000 21 pipe 97500000 22 pipe 97501000 23 inner standpipe 97498000 24 check valve 94074000 25 wall-to-wall mounting set 26397000 26 check valve 96456000 base body for thermostat 97490000 Maintenance Note: The check valves should be removed and cleaned yearly. check valve check valve Troubleshooting Problem Possible Cause Solution Unit outputs both hot and cold water, but it does not mix not a product defect -- the hot and cold supplies are reversed correct the plumbing Water temperature does not get hot enough high temperature limit stop not set correctly reset high temperature limit stop handle not justified justify the handle thermostat...

Questo manuale è adatto anche per i modelli :
Plumbing - ShowerArc 26396001 (4.86 mb)
Plumbing - ShowerArc 26396001 (4.86 mb)
Plumbing - ShowerArc 26396001 (4.86 mb)

Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie