Facilità d'uso
The Pump is manufactured for continuous duty usage. Failure to follow these instructions and warnings may result in pump damage and/or serious injury. Be sure to save this manual for future reference. R Drip Loop WARNING • Risk of electrical shock, this pump is supplied with a grounding conductor and a grounding type attachment plug. To reduce risk of electrical shock, be certain that it is connected only to a properly grounded, grounding-type receptacle. • To reduce the risk of electric shock, use the pump with the flow control only on portable self-contained fountains no larger than 5 feet in any dimension. • The National Electric Code requires that a ground fault circuit interrupter (GFCI) be used in the branch circuit supplying fountain pumps and other pond equipment. See your electrical supplies dealer for this device. • Do not remove grounding pin from the plug. • Do not connect to any voltage other than that shown on the pump. • To reduce risk of electrical shock, always disconnect from power outlet before handling pump or putting your hands into the water. • Do not let pump run dry. • Operate in non-heated fresh water only. Ensure that the pump is completely submerged for proper cooling to assure the pump’s life. • Do not remove the pump by pulling the power cord. • Power cord cannot be replaced; pump should be discarded if any cord damage occurs. • Ensure that the electrical cord loops below the electrical outlet to form a “Drip Loop”. This will prevent water from running down the cord into the electrical outlet. Intake Screen Impeller Discharge Rotating Flow Control Discharge Impeller Intake Screen Impeller Discharge Rotating Flow Control Discharge Impeller MAINTENANCE CAUTION: Always disconnect from the electrical outlet before handling the Pump. IF THE PUMP FAILS TO OPERATE, CHECK THE FOLLOWING: • Check the circuit breaker and try another GFCI protected outlet to ensure the Pump is getting electrical power. • Check the pump discharge, impeller and tubing for obstructions. • Check the intake screen to ensure it is not clogged. • Flush with water to remove any algae build-up. • To clean the Impeller area: rotate the volute 45. counter-clockwise and pull it straight out. Rotate the impeller by hand to ensure that it can spin freely. • Use a stream of water to remove any debris. • Monthly maintenance will add to your Pump’s life. MANUAL del PROPIETARIO de la BOMBA SUMERGIBLE Modelos: M250A y M400A Series Esta bomba se ha examinado y probado cuidadosamente para seguridad y funcionamiento. Fabricada para uso continuo. Sin embargo, el no seguir las instrucciones y advertencias de este manual puede dar como resultado que la bomba sufra danos y/o que se produzcan lesiones graves. Asegurese de leer y conservar este manual para consultas futuras. R Lazo De Goteo ADVERTENCIA • Riesgo de choque electrico, esta bomba se proporciona con un conductor de tierra y un enchufe con conexion a tierra. Para reducir el riesgo de choques electricos, enchufela...
Questo manuale è adatto anche per i modelli :Plumbing - Submersible Pump M400A (346.04 kb)