|
Facilità d'uso
1.4 ROUGHING-IN DIMENSIONS ■ To assure proper positioning in relation THREADED INLETS ROUGHING-IN CAUTION Turn off water at main supply. NOTE When soldering, remove PLASTER GUARD, CARTRIDGES and CHECK STOPS (IF PRESENT). When finished soldering, flush valve body, replace cartridges, check stops (if present) and plaster guard to continue installation. Use thread sealant or Teflon tape on threaded connections. See Roughing-in diagram before starting. Connections are: ■ 1/2" female NPT for threaded inlets Connect RISER PIPE (1) to MANIFOLD (2) top outlet marked "SHR". Connect TUB FILLER PIPE (3) at bottom outlet marked "TUB". For proper positioning the finished wall must be within side wall of PLASTER GUARD (4). 1 If the valve is installed on a fiberglass or other thin wall application, the PLASTER GUARD (4) can be used as a support. ■ Cut a 4" dia. hole in the shower stall. ■ Drill two additional 1" holes to allow access to the stops. ■ Remove PLASTER GUARD (4), rotate 90” so that indicated screw holes fit MANIFOLD (2). ■ Push CAP on valve, place ESCUTCHEON on and attach with screws. Connect hot and cold water supplies. Cap off shower pipe (5) and tub filler pipe (6). For support, use pipe BRACES (7) secured to wooden braces. With valve turned off, turn on water supplies. Check for leaks hOT 3 COLD 1 INSTALL TRIM When finished tiling the wall, remove PLASTER GUARD (3). Push on CAP (1). Mount ESCUTCHEON (2) and with SCREWS (7). Install HANDLE (8) by pushing it onto CARTRIDGE STEM (9) and tightening SET SCREW (10) from below with 2.5mm Hex Wrench supplied. Insert INDEX BUTTON (11). Remove cap from tub supply and plug from shower pipe. Install SHOWER ARM with FLANGE (4) and SHOWER HEAD (5). Install DIVERTER SPOUT (6). 3 ADJUST HOT LIMIT STOP HOT LIMIT SAFETY STOP ADJUSTMENT By restricting handle rotation and limiting the amount of hot water allowed to mix with the cold, the HOT LIMIT SAFETY STOP reduces risk of accidental scalding. To set the maximum hot water temperature of your faucets, all you need to do is adjust the setting on the HOT LIMIT SAFETY STOP "A" ADJUSTMENT WHEN WATER IS TOO HOT TEMPERATURE SETTING NUMBERS 'B" ADJUSTMENT WHEN WATER IS TOO COLD PRY RED RING FORWARD AND ROTATE CLOCKWISE 1 PRY RED RING FORWARD AND ROTATE COUNTER-CLOCKWISE ONE CLICK RED RING"- HOT LIMIT SAFETY STOP SERVICE 1 "off" If faucet drips, operate handle several times from to "on". Do not apply excessive force. Clogged CARTRIDGE (4) inlets may cause reduced flow in "full on" hot or cold. To clean inlets, first turn off water supply, then ■ Remove HANDLE (1), CAP (2) and CARTRIDGE (4). Clean inlets and MANIFOLD (5). ■ Reassemble CARTRIDGE (4), alternately tightening SCREWS (3). ■ Replace CAP (2) and HANDLE (1). Check flow. CARE INSTRUCTIONS: DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH. DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANE...
Questo manuale è adatto anche per i modelli :Plumbing - SYMPHONY 4501 (140.39 kb)
Plumbing - SYMPHONY 4501 (140.39 kb)
Plumbing - SYMPHONY 4501 (140.39 kb)