Log:
valutazioni - 3, GPA: 4.3 ( )

Istruzioni per l'uso Altinex, Modello MT104-100/103

Produttore : Altinex
File Size : 431.41 kb
File Nome : 1e735c0e-611b-4b0c-95ed-caa94f4564ed.pdf
Lingua di insegnamento: en
Vai a scaricare



Facilità d'uso


It is equal to the enclosure slot number in which the card is installed. The value can range from 1 to 4 up to 1 to 20 depending on the enclosure. Card ID 0 (C0) is used for the controller. See the MT100-100 User’s Guide for details. The Group ID is a number representing a group of cards defined with the [WR] command. When using the Group ID, all cards in the group will perform the given instruction. Changing the position of a card will significantly affect the commands recorded on software definitions or third party control systems. The Unit ID has a value from 0 to 9. Unit ID 0 should be used for single unit operation. If the Unit ID is set to zero, each command may be used without Ui. Use the command [SETU0], as explained in the MT100-100 User’s Guide. Example: [VERC3]: For Unit ID Zero [VERC3Ui]: For Unit ID other than Zero [VERC3]: Equivalent to [VERC3U0] 1. [VER] This command receives the software version and card type for the MT104-100/103 card. Command Format: [VERCnUi] Cn = card ID (n = # from 1 to max slots) Ui = Unit ID (i = # from 0 to 9) Example: There is one MT104-100/103 card is in slot #2 of unit 3. Send the command [VERC2U3], and the Multi-Tasker™ Enclosure will return: MT104-100 690-0158-004 MT104-100 = card type 690-0158-004 = software version 2. [C] This command receives the status of the card. Command Format: [CnUi] Cn = Card ID (n = # from 1 to max slots) Ui = Unit ID (i = # from 0 to 9) Example: There is one MT104-100 card in slot #4. Sending the command [C4] to the Multi-Tasker™ will yield the following feedback: ON 4 C04 ON 4 = Output 4 is selected and enabled C04 = The card is in slot 4 If there is no card in slot #4, sending the [C4] command will not return any feedback. 3. [CnS] This command saves the current status of the card. This configuration will be restored after system is reset or powered off then on. Cn = card number (n = #1 to max slots) S = save configuration If Input 1 is enabled, the feedback after sending the command [C4S], for slot 4, would be: ON:1 C04 Saved 4. [?] This command will return general information about the Multi-Tasker™ and cards installed in the unit. Command Format: [?Ui] Cn = Card ID (n = # from 1 to max slots) Ui = Unit ID (i= from 0 to 9) 400-0082-005 9 MULTI-TASKER™ Example: A Multi-Tasker™ has a front panel with part number MT101-101 and contains an MT104-100. Send the command [?] and receive the following feedback: [+MT101-101U0+MT104-100C01] MT101-101U01 = Panel Number and Unit ID MT104-100C01 = An MT104-100 is in slot 1 5. [?Cn] This command will return general information about the card and its status. It is a function of both the card and the front panel and is only available with Multi-Tasker™ Front Panel systems that have the following firmware: 690-0122-015 = Version 015 or later. 690-0123-004 = Version 004 or later. 690-0124-018 = Version 018 or later. NOTE: In MTSetup™, send the command [VER] from the Terminal Window. The system will respond with feedback similar to the following: [690-0122-015 690-0123-004 690-0124-018] Check the last three digits against the numbers above to determine if the option is available. Command Format: [?CnUi] Cn = Card ID (n = # from 1 to max slots) Ui = Unit ID (i= from 0 to 9) Example: The MT104-100 in slot #4 has Input 4 selected and the output is ON. Send the command [?C4] to receive the feedback status. Each status field begins with a '+' and ends with the card slot number (ex: C04). The feedback will be similar to the following: [+MT104-100C04+VR690-0158-004C04+IN4C04] MT104-100 = Card Type VR690-0158-004 = Firmware version IN4 = Input 4 Selected The selected input shows the number of the selected input if the card output is on. If the output is off, the line will not show any input number and would be as follows: +INC04 6. [STA] This command enables/disables automatic feedback from the front panel. The command affects any card with auto-feedback capability, not just the MT104-100/103. The default at power on or reset is STA0, OFF. Command Format [STA1] = ON Command Format [STA0] = OFF Feedback Prefix Definitions: +VR = Firmware Version +IN = Input Selected Example: Command = [ON1C4] Feedback = [+IN1C04] +IN = Input Select 1 = Selected Input C04 = Card slot number 7. [ON] This command enables one input of a single card or a group of cards. There are 8 inputs for the MT104-100 and 6 inputs for the MT104-103. On the MT104-100, Inputs 7 and 8 are internal inputs. [ONmCnUi]: Single Card This command enables input “m” and disables all other inputs. m = Input Number (m = 1 to max inputs) Cn = Card ID (n = slot # from 1 to max slots) Ui = Unit ID (i = 0 to 9) 400-0082-005 10 MULTI-TASKER™ Example: All of the inputs on the MT104-100/103 card are OFF. The card is in slot #5 of Unit 3: 1) [ON1C5U3]: Turns ON only input 1 of the MT104-100/103 card. 2) [ON3C5U3]: Turns ON only input 3 (input 1 is now OFF). [ONmGkUi]: Group of Cards This command enables input "m" for each card in group "k" of unit "i". m = Input ...


Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie