Facilità d'uso


Using this command, the user may also operate the switcher manually. n = ON/OFF switch n = 1 (turns auto switcher ON) n = 0 (turns auto switcher OFF) Example: Sending the [OAS1] command will set the auto switch feature to the ON position to detect the incoming video signal automatically. 9. [0I#] - Change Identification Number This command sets a unique ID number to each MX2456RM Switcher being used. A maximum of 9 unit ID’s can be assigned. 0 = Zero # = New switcher module ID number. (no. from 1 to 9) Example: Sending the command [0I8] will reset the active Switcher module with a new ID number eight. In addition, by default the switchers still have an ID number of zero. 10. [#CA n1 n2 ] - Audio Gain Control Save Settings This command will save the volume settings for a specified audio input. # = Switch number (No. from 1 to 9, Default is 0) n1 = Audio input number (No. from 0 to 6) n2 = Audio Gain (Hexadecimal no. from 1 to F). Example: After executing the [8CA6F] command, switcher module 8 and audio input number 6 will have a maximum volume of F (0 = OFF, default is 8 or normal volume). 11. [#CA n1 n2 ] – Video Equalization Save Settings This command saves the settings of the equalized video signal to compensate for cable distance from the video source to the switcher. # = Switch number (Default is 0. No. from 1 to 9). n1 = Video input number (No. from 0 to 6). n2 = Video equalization (Hexadecimal no. from 1 to F). Example: After executing the [8CA58] command, switcher module 8 and video input number 5 will have a medium equalization range of 8 (0 = OFF). 12. [#VR] - Firmware Version This command displays the firmware revision number installed into the microprocessor. # = Switch number (No. from 1 to 9. Default is 0). 11 SWITCHERS ACCESSORIES 8 Example: After executing the [8VR] command, the system will return the version number 8R1.0. If the user sends the [0VR] command, the system will return the version number 8R1.0. If multiple switchers are used, this command sets a unique ID number for each of the MX2456RM Switchers. Multiple switcher modules can be controlled through a single RS232 port. In order to control multiple modules independently with one RS-232 port, the unit ID must be used. Setting the unit ID allows the user to send the same command to multiple modules, but the module processes that command with the indicated ID number only. The factory default unit ID is1. Model No. Description TABLE MOUNT HARDWARE TM1276 Table Mount bracket for 2U . Rack- Wide RACK MOUNTING ACCESSORIES DA1298RM Rack mount shelf for two units side by side DA1292RM Rack mount ears for single unit. HIGH RESOLUTION 5 BNC to 5 BNC COAXIAL CABLE CB4200MR Bulk Cable 5 coaxes (500ft minimum) CB4203MR 3 feet, 5 BNC to 5 BNC coaxial cable CB4206MR 6 feet, 5 BNC to 5 BNC coaxial cable CB4212MR 12 feet, 5 BNC to 5 BNC coaxial cable CB4225MR 25 feet, 5 BNC to 5 BNC coaxial cable CB4250MR 50 feet, 5 BNC to 5 BNC coaxial cable CB4275MR 75 feet, 5 BNC to 5 BNC coaxial cable CB42100MR 100 feet, 5 BNC to 5 BNC coaxial cable CB42150MR 150 feet, 5 BNC to 5 BNC coaxial cable SUPER HIGH RESOLUTION 5 BNC to 5 BNC COAX CB4400MR Bulk Cable 5 coaxes (500ft minimum) CB4406MR 6 feet, 5 BNC to 5 BNC coaxial cable CB4412MR 12 feet, 5 BNC to 5 BNC coaxial cable CB4425MR 25 feet, 5 BNC to 5 BNC coaxial cable CB4450MR 50 feet, 5 BNC to 5 BNC coaxial cable CB4475MR 75 feet, 5 BNC to 5 BNC coaxial cable CB44100MR 100 feet, 5 BNC to 5 BNC coaxial cable CB44150MR 150 feet, 5 BNC to 5 BNC coaxial cable POWER CABLES PC5301US Power cable for US PC5302US Power cable for UK PC5303US Power cable for Australia PC5304US Power cable for Germany 12 SWITCHERS FREQUENTLY ASKED QUESTIONS 9 TROUBLESHOOTING GUIDE 10 No: Question Answer 1. How do I know which input is connected to which output? LED’s that represent connected video and audio sources will light. 2. Can the MX2456RM be rack mounted? Yes, the MX2456RM can be rack mounted by itself or with two units side by side. The width of the unit is 1-U high. ALTINEX offers rack mount ears for single unit mounting (part # DA1292RM) and rack shelf for mounting two units (part # DA1298RM). 3. How is the MX2456RM controlled? Control can be made through RS-232 or through the connector panel. 4. Why is sync delay switching useful? It eliminates the glitch normally associated with switching between high- resolution RGB type sources. This is accomplishing by disconnecting the sync portion of a signal before the incoming video–making the glitch take place off- screen. The Sync Delay feature is only designed to work with RGBS and RGBHV signal formats. 5. Can the MX2456RM Switcher be used outside of the United States? Yes, the MX2456RM uses a universal internal power supply, enabling it to be used throughout the world. Please make sure to use the proper adapter cables for the country of usage. Adapter cables for several countries are available through ALTINEX. • Please make sure, that input signal formats are the same for the inp...


Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie