|
Facilità d'uso
Commands ending in "P" are not executed immediately. The path for outputs on multiple cards or the same card can be loaded. Command Format: [OFFmCnUiP] m = output number (m =1 to 8) n = card ID No. (n = a slot # from 1 to 19) (1 to 8 for MT100-101 or 1 to 4 for MT100-106) P = path Example: If 2 cards are at slot 6 and 7 of unit 3: To enable output 1 and 2 of card 6 and output 3 and 4 of card 7 simultaneously, use the following commands: OFF12C6U3P] [OFF34C7U3P] [SW] If "F" is included use the [OFFmCnUiPF] command or the [OFFmCnUiFP] command. [OFF…..F]: feedback After processing a command, an OK or ER will be returned as feedback if "F" is included at the end of a command string or if the unit ID is zero. 11 MULTI-TASKER Example: [OFF1C2U3F]: if path is not set [OFF1C2U3PF]: if path is set 6. [SW] – Switch The switch command immediately connects inputs and outputs, which were previously set with the path command on this card or any other cards in the MT100-100. Example: [ON12C6U3P] [ON34C7U3P] [SW] The system will return feedback as OK if the unit ID is zero. 7. [WR] This command groups multiple cards in the MT100-100 Enclosure. Each unit contains a maximum of nine groups. Command Format: [WRCn…GkUi] n = card ID No. (n = slot # from 1 to 19) (1 to 8 for MT100-101 or 1 to 4 for MT100-106 k = group number (k = # from 1-9) i = unit number (i = # from 0-9) Example: To group card #1, 2, and 3 as group 5 of unit #1, send the [WRC1C2C3G5U1] command. After executing this command, card 1, 2, and 3 will be grouped as group 5 of unit 1. OK or ER will be returned as feedback if "F" is included at the end of a command string or if the unit ID is zero. 8. [CLR] This command clears the members for a single group or for all nine groups. [CLRCnUi]: for a single card n = Card ID number (n = 1 to 19) (1 to 8 for MT100-101 or 1 to 4 for MT100-106) Ui = Unit ID number (i = 0 to 9) Note that all outputs will be connected to input1. [CLRGkUi]: for a group of cards Gk = group number (k = # from 1-9) Ui = unit number (i = # from 0-9) Example: a) To clear group #1, send the [CLRG1U1] command. This command clears the members for the specified group only. b) To clear all groups of unit 1, send the [CLRG[U1] command. OK or ER will be returned as feedback if "F" is included at the end of a command string or if the unit ID is zero. 9. [G] This command is used to request group data. With the command, the user can identify which input or output of a particular group is on. Command Format: [GkUi] Gk = group number (k = # from 1-9) Ui = unit number (i = # from 0-9) Example: If group 1 has DA Cards with output 1, 2 and 3 on, while group 2 has SW Cards with input 2 on: 1) [G1]: will return feedback as [On123G1]. 2) [G2]: will return feedback as [On2G2]. 12 MULTI-TASKER 10. [RD] This command displays the members in each group. Command Format: [RDGkUi] k = group number (k = # from 1-9) i = unit number (i = # from 0-9) member = C1 -C19 (card 1 to 19) (1 to 8 for MT100-101 or 1 to 4 for MT100-106) Example: To read member data for group 5 of unit 1, send the [RDG5U1] command. The system will return feedback as C1C2C3 G5U1 11. [HELP] This command displays all available commands for RS-232 control. 7.3.SUMMARY OF COMMANDS. 1) [VER]: Receives software version 2) [C]: Receives status of the card 3) [IO]: Connects the input to the output 4) [ON]: Turns on one or more outputs for a single card or a group of cards 5) [OFF]: Turns off one or more outputs for a single card or a group of cards 6) [SW]: Switch (outputs the preloaded buffer) 7) [WR]: Groups multiple cards 8) [CLR]: Clears members of a single group or all groups 9) [G]: Requests group data 10) [RD]: Displays the members in each group. 11) [HELP]: Displays all commands TROUBLESHOOTING GUIDE 8 We have carefully tested and have found no problems in the supplied MT105-110/(111); however, we would like to offer suggestions for the following: NO DISPLAY Cause 1: The source has a problem. Solution: Check the source and make sure, that there is a signal present and all source connections are correct. If the source is working and there is still no display, see Cause 2. Cause 2: The card input is not selected. Solution: Select the card input. See RS-232 accessible commands in section 7.If no display is present see Cause 3. Cause 3: Cable connections to the destination are incorrect. Solution 1: Make sure that cables are connected properly. Also, make sure that the continuity and wiring are good. If there is still no display present, see Cause 4. Cause 4: The display has a problem. Solution 1: Make sure that the display is powered. If there is still no display, call ALTINEX at (714) 990-2300. 13 MULTI-TASKER ALTINEX POLICY 9 9.0 LIMITED WARRANTY / RETURN POLICY Please see the Altinex website at for details on warranty and return policy. 9.1 CONTACT INFORMATION ALTINEX, INC. 592 Apollo Street Brea, CA 92821 USA TEL: 714-990-2300 TOLL FREE: 1-800-ALTINEX WEB: E-MAIL: solutions...
Questo manuale è adatto anche per i modelli :Apparecchiature di rete - MT105-110 (881.85 kb)
Apparecchiature di rete - MT105-111 (881.85 kb)