|
Facilità d'uso
In MANUAL mode, the connected keyboards are not queried for country information and instead the DEFAULT COUNTRY value is reported to all computers that request country information. In DISABLED mode no country information is supplied to computers requesting country information. AdderView MATRIX MP Installation and Use Page 34 Keyboard Country Codes Country Code Country Code Arabic 01 Persian (Farsi) 20 Belgian 02 Poland 21 Canadian-Bilingual 03 Portugese 22 Canadian-French 04 Russian 23 Czech Republic 05 Slovakian 24 Danish 06 Spanish 25 Finnish 07 Swedish 26 French 08 Swiss/French 27 German 09 Swiss/German 28 Greek 10 Switzerland 29 Hebrew 11 Taiwan 30 Hungary 12 Turkish-Q 31 International (ISO) 13 UK 32 Italian 14 US 33 Japan (Katakana) 15 Yugoslavia 34 Korean 16 Turkish-F 35 Latin American 17 Reserved 36-255 Netherlands 18 Not supported 00 Norwegian 19 3.6.8 MOUSE SWITCHING Accessed from menu: GLOBAL PREFERENCES Settings: ENABLED, DISABLED Like most Adder Technology KVM switches, the AdderView MATRIX MP's channel may be switched using a three button mouse or IntelliMouse (see section 4.9). Pressing the central button or wheel button together with the left hand mouse button will cause the AdderView to switch to the next available computer. When mouse switching is enabled the central mouse button or wheel mouse button is allocated to control the AdderView and is not therefore available for use by computer applications. If you want to use the central mouse button within your applications you will need to disable mouse switching. The rotation action of an IntelliMouse wheel is not affected and is always available to the computer application. 3.6.9 SCREEN SAVER Accessed from menu: GLOBAL PREFERENCES Settings: DISABLED; 2, 5, 7, 10,15, 20 & 30 MINUTES To avoid burning out the phosphor on CRT monitor screens, the AdderView can be AdderView MATRIX MP Installation and Use Page 35 set to blank the screen after no keyboard or mouse activity has been detected for a selected timeout period. If preferred, the user can blank the screen manually by selecting channel '0' using the keyboard hotkeys or by pressing ESC from the login screen. 3.6.10 AUTOSCAN MODE Accessed from menu: GLOBAL PREFERENCES Settings: SCAN LIST, ACTIVE PCs, ALL PCs The AdderView supports an autoscan mode that automatically scans between the connected computers in sequence. The AdderView supports three autoscan modes. In the first mode the AdderView will scan all the named computers that are defined in the autoscan list (SCAN LIST). The computers defined in the scan list may be connected to cascaded AdderViews. If you wish to scan the ports on the current AdderView then you may select ALL the available computers or just the available computers that are currently powered on (the ACTIVE computers). Scanning just the active computers avoids blank screens from being displayed and stops the monitor from going into a power down state on every scan cycle. WARNING - Many modern monitors are fitted with automatic power save relays and will switch off after a few seconds if connected to an inactive PC. If you are using such a monitor you must not set the AdderView to scan ALL ports. Constant switching on and off of your monitor's relay will eventually damage your monitor. If you are using the SCAN LIST option then you should ensure that all the computers are active if you are using one of these monitors. If you choose to use the SCAN LIST option then you may define the computers to be scanned in the following manner. To define the autoscan list Ensure that you are logged on as the ADMIN user. From the main on-screen menu press F1 for MORE MENUS. Select EDIT AUTOSCAN LIST from the menu. A list of defined computers will appear. The starred computers will be autoscanned during the autoscan cycle. To add a computer to the autoscan list, move the selection bar over the computer name and press SPACE BAR. To add all named computers press F1. To remove all named computers press F2. AdderView MATRIX MP Installation and Use Page 36 When all the computers that you wish to scan have a star to the right hand side of their name, press RETURN or ENTER to save the selections. The selected computers will be autoscanned in alphabetical order when you activate autoscan mode (when the SCAN LIST option is selected). 3.6.11 AUTOSCAN PERIOD Accessed from menu: GLOBAL PREFERENCES Settings: DISABLED; 2, 5, 7, 10, 15, 20, 30 SECONDS The autoscan time defines the length of time that the AdderView will display video from an autoscanned computer before changing to the next computer. If the DISABLED setting is chosen then no autoscan functions will be available. 3.6.12 OSD DWELL TIME Accessed from menu: GLOBAL PREFERENCES Settings: 1, 2, 3, 5, 10 SECONDS After a successful computer channel change the AdderView will display a confirmation message for a few seconds. The length of time that this confirmation message dwells on the screen may be changed. Options are 1, 2, 3, 5 & 10 secs. 3.6.13...
Questo manuale è adatto anche per i modelli :Apparecchiature di rete - AVM208MP (1.86 mb)