Log:
valutazioni - 0, GPA: 0 ( )

Istruzioni per l'uso HP, Modello HP Smart Array (RAID) Host Bus Adapters

Produttore : HP
File Size : 314 kb
File Nome :
Lingua di insegnamento: en
Vai a scaricare



da questo dispositivo ha anche altre istruzioni :

Facilità d'uso


Severity: Low
Corrective Action: To avoid this CRA failure, before running swremove install patch
PHCO_36356 (or a superseding patch). Patches are available from the HP IT Resource Center
at:
http://itrc.hp.com/
Under “Maintenance and Support,” click the Patch Database link, then search for the patch
number. For more information on how to manage and install patches, see the Patch
Management User Guide for HP-UX 11.x Systems
at:
http://docs.hp.com/en/oshpux11iv3.html
NOTE:
If you remove the dynamically loaded ciss driver while it is in use, or if you remove
the statically loaded ciss driver at any time, you must perform a reboot. This is normal
behavior under these conditions, and is not affected by patch PHCO_36356.

Automatic hot-plug is not detected.
The HP Smart Array Controllers do not automatically detect the hot-plug of internal disks.
Corrective Action: After replacing a physical disk, run the sautil command with the scan
option.
4.2 For Parallel SCSI Smart Array Controllers

Partially disconnected disks and external cables are not properly detected by ioscan.
If you remove all but one cable connecting external storage enclosures, or if you remove
physical disks that are part of a logical drive from the enclosures, saconfig and sautil
show the status of the logical drive as FAILED. However, ioscan reports the status of the
disks incorrectly.
Corrective Action: Reconnect the cables or reinsert the disks, then reset the Smart Array
controller using the sautil reset_ctlr command. After the controller is reset, ioscan
correctly reports the status of the disks as CLAIMED.

Disconnected external storage enclosures are not properly detected by ioscan.
If you disconnect all cables connecting a Smart Array controller to external storage enclosures,
saconfig and sautil show the status of the logical drives as FAILED. However, ioscan
continues to report the status of the disks as CLAIMED.
Corrective Action: Reset the Smart Array controller using the sautil reset_ctlr
command. When the controller is reset, ioscan correctly reports the status of the disks as
NO_HW.

Controller fails when two connectors are used on the same channel.
Each channel has two connectors (one internal and one external), but only one connector
can be used per channel at any given time. If you attempt to boot the system with storage
devices connected to the internal and external connectors on the same channel, the controller
fails.
Corrective Action: Shut down and power off the system, fix the cabling issue, and power
on the system.
4.3 For SAS (Serial-Attached SCSI) Smart Array Controllers

Special considerations apply when upgrading a server with an MSA2300 Series enclosure
to HP-UX 11i v3 Application Release 0909.

HP-UX 11i v3 Application Release 0909 (AR0909) contains the RAID-01 B.11.31.0903 bundle.
Servers with an MSA2300 Series enclosure as part of the configuration have RAID-01 version
6


...

Questo manuale è adatto anche per i modelli :
Apparecchiature di rete - HP-UX 11i v3 I/O Cards (314 kb)

Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie