Log:
valutazioni - 1, GPA: 5 ( )

Istruzioni per l'uso Sioux Tools, Modello 5978A

Produttore : Sioux Tools
File Size : 2.09 mb
File Nome : ZCE568~1.pdf
Lingua di insegnamento: itenesfrdenl
Vai a scaricare



Facilità d'uso


Box 1596 Murphy, NC 28906 U.S.A. Tel No. 828-835-9765 Fax No. 828-835-9685 Important Read these instructions carefully before installing, operating, servicing or repairing this tool. Keep these instructions in a safe accessible place. Product Type 1/8" (3 mm) Pencil Air Die Grinder Model No/Nos 5978A RPM 54,000 Cycles Per Min. C€ Serial No. Product Net Weight 0.44 lbs 0.20 Kg Recommended Use Of Balancer Or Support N0 Recommended Hose Bore Size - Minimum 5/16 ins 8 mm Recommended Max. Hose Length 30 Ft 10 M Air Pressure Recommended Working 6.2 bar 90 PSI Maximum 6.2 bar 90 PSI Noise Level: Sound Pressure Level 72.0 dB(A) Sound Power Level 84.0 dB(A) Test Method: Tested in accordance with Pneurop test code PN8NTC1 and,ISO Standard 3744 SAFETY MESSAGES * * Personal Safety Equipment Use - Safety Glasses YES Use - Safety Gloves YES Use - Safety Boots Use - Breathing Masks YES Use - Ear Protectors YES A WARNING Vibration Level 2.0 Meters / Sec2 Always Read Instructions Before Using Power Tools Always Wear Safety Goggles Wear Hearing Protection Avoid Prolonged Exposure To Vibration Test Method: Tested in accordance with ISO standards 8662 Parts 1 & 13 Safety rules when using 5978A Pencil Die Grinder - Use accessories rated at least 54,000 RPM. - Prolonged exposure to vibration may cause injury. -Read all instructions before using this tool. All operators must be fully trained in its use and aware of these safety rules. - Do not exceed the maximum working air pressure. - Use personal protection equipment as recommended. - Some dust created by power sanding, sawing, grinding, drilling, and other construction activities contains chemicals known to cause cancer, birth defects and other reproductive harm. -Use only compressed air at the recommended conditions. - If the tool appears to malfunction, remove from use immediately and arrange for service and repair. If it is not practical to remove tool from service, then shut off the air supply to the tool and write or have written a warning note and attach it to the tool. - If tool is to be used with a balancer or other suspension device, ensure that the tool is firmly attached to the suspension/support device. - When operating the tool, always keep the body and particularly the hands away from the working attachment fixed to the tool. -The tool is not electrically insulated. Never use the tool if there is any chance of coming into contact with live electricity. - Always when using the tool, adopt a firm footing and/or position and grip the tool sufficiently only to overcome any reaction forces that may result from the tool doing work. Do not overgrip. - Use only correct spare parts for maintenance and repair. Do not improvise or make temporary repairs. Major servicing and repairs should only be carried out by persons trained to do so. - Do not lock, tape, wire, etc. the ‘On/Off valve in ‘On’ position. The trigger/lever, etc. must always be free to return to the ‘Off’ position when released. - Always shut off the air supply to the tool and press the 'On/Off' valve to exhaust the air from the feed hose before fitting, removing or adjusting the working attachment fitted to the tool. . - Before using the tool, make sure that a shut off device All Pipe And Fittings Should Be 1/2" Or Larger«, Compressor with Sufficient Capacity To Maintain Recommended Working Pressure At Each Tool Outlet G*=S< Take Air From Top Recommended Air Supply System Figure 1 Page No 1 has been fitted to the air supply line and the position is known and easily accessible so that the air supply to the tool can be shut off in an emergency. - Cheek hose and fittings regularly for wear. - Take care against entanglement of the moving parts of the tool with clothing, hair, ties, cleaning rags, rings, jewelry, watches, bracelets, etc. This could cause the body or parts of the body to be drawn towards and in contact with the moving parts of the tool and could be very dangerous. -It is expected that users will adopt safe working practices and observe all local, regional and country legal requirements when installing, using or maintaining the tool. - Take care that the exhaust air does not point towards any other person or material or substance that could be contaminated by oil droplets. When first lubricating a tool or if the tool exhaust has a high oil content, do not allow the exhaust air to come near very hot surfaces or flames. - Never lay the tool down until the working attachment has stopped moving. - When the tool is not in use, shut off the air supply and press the trigger/lever to drain the supply line. If the tool is not to be used for a period of time, first lubricate, disconnect from air supply and store in a dry average room temperature environment. -If the tool is passed from one user to a new or inexperienced user, make sure these instructions are passed with the tool. - Do not remove any manufacturer fitted safety devices where fitted...


Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie