The meter should read between 13.5K and 19.5K ohms. Turn the knob all the way clockwise, the meter should read between 108K and 132K ohms. If continuity is present at all positions, the potentiometer switches are operating properly. If continuity is not present at any position, replace the potentiometer switches. 8. Refer to Fig 35 when reconnecting wires. Removal and Replacement: 1. Disconnect the grinder from the power source. 2. Remove the four 8-32 screws attaching the rear access panel and