1 micron resolution below 200 micron of vacuum Sensor Type Thermistor Connector Type Standard 1/4 inch male flare fitting Vacuum Range 0 - 12,000 Microns (0 - 1,600 Pascals) with vacuum increasing/decreasing indicator when above 12,000 Microns Scale Microns, PSI, InHg, milliBars, Pascals, Torr, milliTorr Operating Temp. Range 35°F to 125°F ( 2°C to 52°C) Overpressure 300 PSI max (20 Bar) Accuracy +/-10% (0 to 1000 microns) Power Source 9 Volt Alkaline battery (not included) Continuous Usage Over 35 hours Auto Shut off After 10 minutes when vacuum reading is above 12,000 Microns (12 Torr) Weight 6.7 ounces Dimensions 5-1/2"H X 3"W X 1-1/4"D DVG64 STEP TABLE Vacuum (microns) Micron (mTorr) Step Pascal Step Bar Step InHg Step PSI Step 15000 - 8000 1000 100 1 0.05 0.02 8000 - 5000 500 50 0.5 0.02 0.01 5000 - 2000 250 25 0.25 0.01 0.005 2000 - 1000 50 5 0.05 0.002 0.001 1000 - 500 10 1 0.01 0.0005 0.0002 500 - 200 5 0.5 0.0005 0.0002 0.0001 200 - 0 1 0.1 0.0001 0.00005 0.00002 FEATURES • Reads vacuum in 7 international units • Uses . the battery power than other models • Cleaning port provides quick cleaning and drying of sensor • Uses standard 9V Alkaline battery • Convenient built-in hanger OPERATING CONTROLS • Turning the vacuum gauge ON: Press and hold the ON button for about 3 seconds, until "POWER UP" appears on the display. • Turning the vacuum gauge OFF: Press the OFF button To prolong battery life, when vacuum reading is above 12,000 Microns for about 10 minutes, the unit will automatically turn OFF. • Changing the scale: Press the Scale button to change the display to the next scale. The scale order is: Microns, PSI, Inches of mercury (InHg), milliBars, Pascals, Torr and milliTorr. DVG64 will keep the scale settings even if the power is turned OFF. UNDERSTANDING THE DISPLAY • When the vacuum reading is above 12,000 Microns (1,600 Pascals), the first line of the display shows "Atm." The second line displays a bar graph to indicate the direction in which the vacuum is moving. When the bar graph is moving from left to right, the pressure is increasing. When the bar graph is moving from right to left, the pressure is decreasing. The speed of the bar graph indicates how fast the pressure is increasing or decreasing. The bar graph indicator may be inaccurate for a few seconds after the evacuation of the system has begun. • The bar graph disappears if the vacuum does not change for about 10 seconds. When the vacuum reading is below 12,000 Microns (1,600 Pascals), the vacuum in the selected units is displayed. CONNECTING TO THE VACUUM SYSTEM The VG64 should only be connected to the vacuum system at the vacuum port. The "Auxiliary Port" is primarily for cleaning and should normally be closed with the supplied cap. CLEANING THE VACUUM SENSOR It is recommended that the sensor be cleaned periodically to maintain unit accuracy . Oil and other contaminants reduce the accuracy of the unit. Follow the instructions below for cleaning. • Close the Vacuum port with the supplied cap. Open the Auxiliary port. • Use an eyedropper to pour about 2 teaspoons of ordinary rubbing alcohol into the Auxiliary port. • Close the Auxiliary port with the supplied cap. Both the Vacuum and Auxiliary ports should now be closed. • Shake the DVG64 unit for about 10 seconds. A slight movement of the vacuum sensor in the case is normal and does not affect the internal connection in any way. • Open both the Vacuum and the Auxiliary ports. Empty the alcohol, and air dry the sensor. • Close both the Vacuum and the Auxiliary ports with the supplied caps when the DVG64 is not used. This prevents contamination of the sensor. OMEGAnet® Online Service Internet e-mail info@omega.com OMEGAnet® Online Service Internet e-mail info@omega.com Servicing North America: USA: One Omega Drive, Box 4047 ISO 9001 Certified Stamford CT 06907-0047 Tel: (203) 359-1660 FAX: (203) 359-7700 e-mail: info@omega.com Canada: 976 Bergar Laval (Quebec) H7L 5A1 Tel: (514) 856-6928 FAX: (514) 856-6886 e-mail: info@omega.ca For immediate technical or application assistance: USA and Canada: Sales Service: 1-800-826-6342 / 1-800-TC-OMEGA® Customer Service: 1-800-622-2378 / 1-800-622-BEST® Engineering Service: 1-800-872-9436 / 1-800-USA-WHEN® TELEX: 996404 EASYLINK: 62968934 CABLE: OMEGA Mexico: En Espan.ol: (001) 203-359-7803 e-mail:espanol@omega.com FAX: (001) 203-359-7807 info@omega.com.mx Servicing Europe: Benelux: Postbus 8034, 1180 LA Amstelveen, The Netherlands Tel: +31 (0)20 3472121 FAX: +31 (0)20 6434643 Toll Free in Benelux: 0800 0993344 e-mail: sales@omegaeng.nl Czech Republic: Rude armady 1868, 733 01 Karvina 8 Tel: +420 (0)69 6311899 FAX: +420 (0)69 6311114 Toll Free: 0800-1-66342 e-mail: info@omegashop.cz France: 11, rue Jacques Cartier, 78280 Guyancourt, France Tel: +33 (0)1 61 37 29 00 FAX: +33 (0)1 30 57 54 27 Toll Free in France: 0800 466 342 e-mail: sales@omega.fr Germany/Austria: Daimlerstrasse 26, D-75392 Deckenpfronn, Germany Tel: ...