Facilità d'uso
To determine the minimum wire size required, refer to the chart below. Before using an extension cord, inspect it for loose or exposed wires, damaged insulation, and defective fittings. Make any needed repairs or replace the cord if necessary. VEA EL ESPANOL EN LA CONTRAPORTADA. SAVE THIS MANUAL FOR FUTURE REFERENCE. INSTRUCTIVO DE OPERACION, CENTROS DE SERVICIO Y POLIZA DE GARANTIA. ADVERTENCIA: LEASE ESTE INSTRUCTIVO ANTES DE USAR EL PRODUCTO. Catalog Number BV2800 Form No. 617365-00 Cat. # BV2800 (MAY ‘03) Copyright © 2003 Black & Decker Printed in Mexico KEY INFORMATION YOU SHOULD KNOW: • Before operating, make sure that either the blower or vacuum tube assembly is locked in place. • The power switch must be OFF in order to depress the release button for changing blower and vacuum tube assemblies. Release Button Bouton de degagement Boton de liberacion 1 5 Blowing Mode Mode de soufflage Modo de Soplador O ON En marche Encendido OFF Arret Apagada 9 8 Vacuuming Mode Mode d'aspiration Modo de Aspiradora 9B Extension Tube Tube de rallonge Tubo de Extension Vacuum Tube Tube d.aspiration Tubo de Aspirado 9A 11 12 13 DATE CODE BEFORE RETURNING THIS PRODUCT FOR ANY REASON PLEASE CALL 1-800-54-HOW-TO (544-6986) IF YOU SHOULD EXPERIENCE APROBLEM WITH YOUR BLACK & DECKER PRODUCT, CALL 1-800-54-HOW-TO (544-6986) BEFORE YOU CALL, HAVE THE FOLLOWING INFORMATION AVAILABLE, CATALOG No., TYPE No., AND DATE CODE. IN MOST CASES, ABLACK & DECKER REPRESENTATIVE CAN RESOLVE YOUR PROBLEM OVER THE PHONE. IF YOU HAVE ASUGGESTION OR COMMENT, GIVE US ACALL. YOUR FEEDBACK IS VITAL TO BLACK & DECKER. 10 Switch Interrupteur Interruptor WARNING: IMPORTANT SAFETY WARNINGS AND INSTRUCTIONS GENERAL SAFETY WARNINGS AND INSTRUCTIONS FOR ALL TOOLS SERVICING OF DOUBLE INSULATED APPLIANCES SAFETY RULES AND INSTRUCTIONS: EXTENSION CORDS Minimum Gage for Cord Sets Volts Total Length of Cord in Feet 120V 0-25 26-50 51-100 101-150 240V 0-50 51-100 101-200 201-300 Ampere Rating More Not more American Wire Gage Than Than 0 - 6 18 16 16 14 6 - 10 18 16 14 12 10- 12 16 16 14 12 12- 16 14 12 Not Recommended Lock button Bouton de verrouillage Boton de seguridad 6 7 14 Blowing Mode w/Flex Tube Mode de soufflage avec tube flexible Modo de soplador c/tubo flexibe 15 2A 3 4 2 INSTRUCTION MANUAL SAFETY WARNINGS AND INSTRUCTIONS: POLARIZED PLUG To reduce the risk of electric shock, this equipment has a polarized plug (one blade is wider than the other). This equipment must be used with a suitable polarized 2 wire or 3 wire extension cord. Polarized connections will fit together only one way. Make sure that the receptacle end of the extension cord has large and small blade slot widths. If the plug does not fit fully into the extension cord, reverse the plug. If it still does not fit, obtain a suitable extension cord. If the extension cord does not fit fully into the outlet, contact a qualified electrician to install the proper outlet. Do not change the tool plug or extension cord in any way. BEFORE OPERATING • SECURING POWER SUPPLY CORD - Secure the extension cord in the tool's built-in cord retainer as shown in Figure 14 or secure the power supply cord and a suitable extension cord as shown in Figure 15. SWITCH NOTE: The switch will not operate if the release button, shown in Figure 1, is depressed. To turn the tool ON, slide the switch forward, as shown in Figure 1. To turn tool OFF, slide switch to the rear. OPERATION USE AS A BLOWER: ALWAYS WEAR SAFETY GLASSES, WEAR A FILTER MASK IF THE OPERATION IS DUSTY. USE OF RUBBER GLOVES AND SUBSTANTIAL FOOTWEAR IS RECOMMENDED WHEN WORKING OUTDOORS. FOR HOUSEHOLD USE ONLY. • BLOWER MODE - STRAIGHT TUBES ONLY Ensure that the unit is switched OFF and is disconnected from the power supply. Assemble blow tubes as shown in Figure 2 and Figure 2A. (This only needs to be done the first time you assemble the unit.) WARNING: When turning the tool off for tube installation or any other reason, wait 10 seconds for the fan to stop rotating before disassembly. Attach the blower tube assembly (The assembly includes the blower tubes, and the fan chamber) to the front of the tool, as shown in Figure 3 by inserting point A into the matching recess marked point B, also shown in Figure 3. Swing the tube up to engage the lock, as shown in Figure 4. NOTE: The lock will not engage if the ON/OFF switch is in the forward (ON) position. Hold the end of the blower tube approximately 7 inches (180mm) above the ground and turn the tool ON. Using a sweeping motion, from side to side, advance slowly keeping the accumulated debris (leaves,grass clippings etc.) in front of you, as shown in Figure 5. Once you have blown the debris into a pile, you can convert to vacuum mode to collect the debris for disposal. • BLOWER MODE - FLEX TUBE Ensure that the unit is switched OFF and is disconnected from the power supply. Assemble flex blow tube as shown in Figure 6. WARNING: When turning the tool off for tube installation or any other reason, wait 10 seco...
Questo manuale è adatto anche per i modelli :Sistemi di ventilazione - Leaf Hog 617365-00 (463.1 kb)