Facilità d'uso
Remove the crate and protective cover as soon as possible and check the items listed on the packing list. Advise the carrier of any damaged or missing articles as soon as possible. A written claim should be filed with the carrier immediately if articles are damaged or missing. IMPORTANT: Warranty is void unless tumbler is installed according to instructions in this manual. Installation should comply with minimum specifications and requirements detailed herein, and with applicable local gas fitting regulations, municipal building codes, water supply regulations, electrical wiring regulations, and any other relevant statutory regulations. Due to varied requirements, applicable local codes should be thoroughly understood and all pre-installation work arranged for accordingly. 4-08-43 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 10 Tumblers – T30 and T45 TMB2110N NOTE: Shaded areas indicate adjacent structure. 1 0.5 in. (13 mm) recommended between machines for removal or installation. 2 Allow 2 – 4 in. (51 – 102 mm) opening at top of machine to aid in removal or installation. A removable trim piece may be used to conceal the opening; zero clearance allowed for trim. 3 4 in. (102 mm) Maximum Header Thickness 4 12 in. (305 mm) Minimum Clearance 5 24 in. (610 mm) Minimum, 36 in. (914 mm) recommended for maintenance purposes. 6 Provision for Make-Up Air: Minimum 1.5 square feet T30 models, minimum 2 square feet T45 models. Location for reference only. May be anywhere behind tumbler. 7 0.25 in. (6 mm) recommended for removal or installation purposes, zero clearance allowed. WARNING To reduce the risk of severe injury, clearance of tumble dryer cabinet from combustibleconstruction must conform to the minimum clearances. W056R1 7 4 6 31 5 Figure 1 11 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 4-08-43 Tumblers – T30 and T45 Exhaust Requirements Venting WARNING A drying tumble dryer produces combustible lint. To reduce the risk of fire, the tumble dryer must be exhaustedto the outdoors. W057R1 To reduce the risk of fire and accumulation of combustible gases, DO NOT exhaust tumble dryer air into a window well, gas vent, chimney or enclosed, unventilated area such as an attic wall, ceiling, crawl space under a building, or concealed space of a building. W059R1 Layout Whenever possible, install tumblers along an outside wall where duct length can be kept to a minimum, and make-up air can be easily accessed. Elbows and long vents tend to increase drying time. Construction must not block the airflow at the rear of the tumbler. Doing so would prevent adequate air supply to the tumbler’s combustion chamber. Make-Up Air A tumbler is forced air exhausted and requires provisions for make-up air to replace air exhausted by the tumbler. IMPORTANT: Do not obstruct the flow of combustion and ventilation air. Make-up air openings should be as close to the tumbler(s) as possible. The required make-up air opening to the outside for each tumbler (includes both pockets) is: 220 square inches (1418 sq. cm) for T30 models 288 square inches (1856 sq. cm) for T45 models Make-up air openings with louvers will restrict airflow. The opening must be increased to compensate for area taken up by louvers. Make-up air openings for a room containing tumbler(s) and/or gas fired hot water heater or other gravity vented appliances must be increased sufficiently to prevent downdrafts in any of the vents when all tumblers are in operation. Do not locate gravity vented appliances in the same room as tumblers. If it is necessary to duct make-up air to the tumbler(s), increase the area of the ductwork by 25% to compensate for any restriction in air movement. WARNING To reduce the risk of fire due to increased static pressure, we do not recommend installation of in-line secondary lint filters or lint collectors. If secondary systems are mandated, frequently clean the system to assure safe operation. W749 IMPORTANT: Installing in-line filters or lint collectors will cause increased static pressure. Failure to maintain the secondary lint system will decrease tumbler efficiency and may void machine warranty. For maximum efficiency and minimum lint accumulation, tumbler air must be exhausted to the outdoors by the shortest possible route. Proper sized exhaust ducts are essential for proper operation. All elbows should be sweep type. Exhaust ducts must be assembled so the interior surfaces are smooth, so the joints do not permit the accumulation of lint. DO NOT use plastic or thin foil ducts – rigid metal ducts are recommended. Use exhaust ducts made of sheet metal or other noncombustible material. DO NOT use sheet metal screws or fasteners on exhaust pipe joints which extend into the duct and catch lint. Use of duct tape or pop-rivets on all seams and joints is recommended, if allowed by local code. Verify that old ducts are thoroughly cleaned out before installing new tumbler(s). WARNING Improperly sized or assemble...
Questo manuale è adatto anche per i modelli :Sistemi di ventilazione - T30 (468.68 kb)