|
da questo dispositivo ha anche altre istruzioni :
Facilità d'uso
23 Scanning Applications and Settings Using DSmobileCapture (for Macintosh) 1 Connect the supplied Micro USB Cable to the Micro USB port on your scanner. Connect the cable to your computer. 2 Double-click the DSmobileCapture shortcut on your desktop. 3 DSmobileCapture launches. 5 4 Change the scanning settings, if needed. For more information on changing settings, see Changing DSmobileCapture scan settings (for Macintosh) on page 25. 5 Insert a document into your scanner. 6 Click Scan in the DSmobileCapture screen or press the scanner’s Start button. Your scanner starts scanning. The scanned image will be saved in the directory you specified in step 4. Check the scan result just in case. 24 Scanning Applications and Settings Changing DSmobileCapture scan settings (for Macintosh) Image settings Click the Image tab to choose image type and to set several basic scan settings. NOTE This image is from the DS-720D. (1) (2) (7) (8) (9) (3) (4) (5) (6) (10) 5 (1) Image Selection Box Choose the type of document you want to scan. (2) Duplex (DS-720D only) Select the Duplex check box to perform Duplex (2 sided) scanning. (3) Brightness Adjusts the lightness or darkness of an image. The range is from -100 to +100. The factory default is 0. (4) Contrast Adjusts the range between the darkest and the lightest shades in the image. The range is from -100 to +100. The factory default is 0. (5) Resolution Determine the quality of the scanned image. The factory default is 200 dpi. (6) Invert Reverse the brightness and the colours in the image. (7) Page Size Page Size allows you to capture a portion of the scanned document. Choose your paper size from the Page Size pop-up list. (8) Profiles Save or change the scanning setting in the dialog box of Scanner Properties. (9) Default Reset values in this and all other Properties tabs to the original factory settings. 25 Scanning Applications and Settings (10) Preview Window Click to preview your image before scanning. This preview image helps you define your scan area. When you click Preview, scanning for the preview starts and the scanned image will appear in the Preview Window. Note that the scanned image is only for the preview and will not be saved. 5 26 Scanning Applications and Settings File settings Click the File tab to configure the settings related to the file name and the directory where you want to save the scanned image. (1) (2) (3) (4) (5) (6) (7) (9) (8) 5 (1) Directory Specify the directory where you want to save scanned images. (2) File Name Set the rule for the file name of the scanned image. (3) Digits Determine the starting number of the sequence number that is included in the file name. (4) Sample Preview the file name that you set. (5) When file names are the same Change the file name if the same name already exists in the directory you chose in Directory. (6) File Format Choose the file format for the scanned image. When you choose TIFF or PDF, the Multi Page Output option is available. You can continue to scan the next document after the first scan job is completed. (7) Scan to Choose the destination to send the scanned image. (8) Default Reset values in this and all other Properties tabs to the original factory settings. (9) Preview Window Click to preview your image before scanning. This preview image helps you define your scan area. When you click Preview, scanning for the preview starts and the scanned image will appear in the Preview Window. Note that the scanned image is only for the preview and will not be saved. 27 Scanning Applications and Settings Paper settings Click the Paper tab to define values related to image output. (2) (1) (4) (3) 5 (1) Page Size Page Size allows you to capture a portion of the scanned document. Choose your paper size from the Page Size pop-up list, define the X Offset and Y Offset values or specify Width and Length to define your scanned area. Click Preview Window (4) to preview the image placement as you change the values. • X Offset - the distance from the left edge of the document to the left edge of the scanned area. • Y Offset - the distance from the top edge of the document to the top edge of the scanned area. • Width - the width of the scanned area. • Length - the length of the scanned area. (2) Unit Unit allows you to define your preferred measurement system. Select Inches, Millimeters, or Pixels from the pop-up list. (3) Default Reset values in this and all other Properties tabs to the original factory settings. (4) Preview Window Click to preview your image before scanning. This preview image helps you define your scan area. When you click Preview, scanning for the preview starts and the scanned image will appear in the Preview Window. Note that the scanned image is only for the preview and will not be saved. 28 Scanning Applications and Settings Options settings Click the Options tab to set some additional image processing settings or calibrate your scanner. (1) (2) (3) (4) (5) 5 (1) Rotation Degrees Choose the ro...
Questo manuale è adatto anche per i modelli :scanner / copiatrice / MFP - DS-620 (2.72 mb)