Facilità d'uso
Note when controlling your ACURIS instruments audio input with the ePocket: If an audio shoe is attached to one or both of your ACURIS hearing instruments, the program button on the ePocket or on the instruments can be used to select the audio mode (such as only audio, only microphone, or audio and microphone). The volume can be changed normally using the ePocket. If you are wearing one ACURIS hearing instrument with audio input capability and one without (for example, if you are wearing a Behind-the-Ear instrument and In-the-Ear instrument), the instrument with the audio shoe connected cannot be controlled using the ePocket. Using the telephone The telecoil mode is intended for telephone use. In the telecoil mode, place the telephone receiver close to your hearing instrument for best reception. By trying various positions with the telephone receiver, you will discover what works best for you. Note: In order for the telecoil to function properly, your telephone must be "hearing instrument compatible.” Check your telephone’s instruction manual to find out whether your phone has this capability. Your hearing instrument specialist can advise you on the proper use of the telecoil program. Not all telephones, especially cordless telephones and mobile phones, produce a magnetic field required for use with the telecoil. In such cases we recommend that you use the telephone while in the program set for universal hearing situations (most likely Program 1). 19 Maintenance and care Your new ACURIS hearing system is a highly sensitive system. Proper care and handling will ensure the best possible performance. Earwax may accumulate on your earmold. If not cleaned regularly you can damage the hearing systems or cause health problems. Therefore: 1. It is essential to detach the earmold from your behind-theear system and place it in the cleaning bath. Caution: Do NOT put the hearing system in water, only the earmold. 2. Occasionally bring your hearing system to your hearing instrument specialist to regularly to have the hearing tube changed and the system checked. Care tips: • You should place your hearing system in a "dry aid kit" with a special moisture-attracting capsule overnight. The drying capsule draws damaging moisture out of the system. • Your hearing instrument specialist can supply you with special care sets and drying capsules to keep your hearing system in good condition. Always store your hea- ring system in the case provided. 20 Important notes • Never expose your hearing system to extreme temperatures or high humidity. Do not store it in direct sunlight. Do not wear it when taking a shower or when using hairspray. • As with all electrical, non gas-encapsulated systems, the hearing system must not be operated in explosion- endangered rooms. • Do not wear your hearing system during short-wave therapy, or if you work or are medically treated with strong magnetic or high-frequency fields • Make sure to turn off the system when not in use. This helps preserve your batteries. • When not wearing your system for long periods of time, remove the batteries. This prevents leakage, which can some times occur in batteries. Replace batteries that have a leakage immediately. • This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. • Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. IC: 267AB-WL001 21 Troubleshooting tips Your ACURIS hearing system is an extremely dependable device. However, should a problem occur, this can usually be corrected quickly. Use this trouble shouting guide to sort out simple problems. PROBLEM CAUSE POSSIBLE SOLUTION System sound is weak Weak or dead battery System clogged Volume too low Replace with new battery Clean earmold Turn up volume control System whistles Improper seating in ear Volume control too high Clogged with wax or excessive wax in ears Crack in earmold tubing Try reinserting the instrument until it fits securely Lower volume control Clean earmold or contact your hearing instrument specialist See your hearing instrument specialist 22 PROBLEM CAUSE POSSIBLE SOLUTION Sound is Volume control too Lower volume control distorted or high intermittent Weak battery Replace battery “Buzzing” or Battery compartment Gently close the “whistling” is not completely battery compartment sound closed Weak battery Replace battery Hearing System not Turn on system system turned on does not work Battery compartpartment is not completely closed Dead battery Battery polarity reversed Gently close the battery compartment completely Replace with new battery Make sure battery is inserted correctly If you still encounter problems after trying these suggestions, consult your hearing instrument sp...
Questo manuale è adatto anche per i modelli :Apparecchi acustici - S (272.4 kb)