Circuit Requirements: An individual, properly-grounded branch circuit of the proper voltage and frequency as specified on the rating plate, with no other appliances or fixtures in circuit, is required. For answers to your Monogram,® GE Profile Performance Series,™ GE Profile™ or GE appliance questions, call GE Answer Center® service, 800.626.2000. Listed by Underwriters Laboratories GE Appliances WSLS1100A/DSKS433A–GE Spacemaker® Stationary Washer and Dryer With Stack Rack Best Performance For complete information, see installation instructions packed with your dryer. Maximum Length of 4" Dia. Rigid Metal Duct Exhaust Hood Type Maximum Length of 4" Dia. Flexible Metal Duct Exhaust Hood Type Ducting Materials: For best performance, this dryer should be vented with 4” diameter all rigid metal exhaust duct. If “all rigid metal” duct cannot be used, then “flexible all metal” venting can be used, but it will reduce the maximum recommended duct length. Number of Cat. No. WX8X59 Cat. No. WX8X59 Exhaust Length Calculation: 1. Determine the number of 90° turns needed for your installation. If you exhaust to the side or bottom of dryer, add one turn. Domestic Dryer Models 90° Turns (Preferred) A 4" Opening B 2-1/2" Opening (Preferred) A 4" Opening B 2-1/2" Opening 2. The maximum length of 4’ rigid (aluminum or galvanized) duct which can be tolerated is shown in the table. The maximum length for flexible ducts are less than for rigid duct. 0 46 ft. 37 ft. 30 ft. 24 ft. A turn of 45° or less may be ignored. Two 45° turns within the duct length should be treated as a 90° elbow. A turn over 45° should be treated Spacemaker ® Models 1 38 ft. 30 ft. 25 ft. 20 ft. as a 90° elbow. DSKS433EW WSM2780T 2 3 0 31 ft. 24 ft. 43 ft. 22 ft. 15 ft. 36 ft. 20 ft. 16 ft. 30 ft. 14 ft. 10 ft. 24 ft. Exhausting the dryer to the outside is strongly recommended to prevent large amounts of moisture and lint from being blown into the room. Gas dryers or any dryer located in a closet must be exhausted to the outside. Spacemaker ® Model DSKP233EW 1 3 33 ft. 23 ft. 26 ft. 16 ft. 24 ft. 16 ft. 18 ft. 10 ft. Caution: For personal safety do not terminate exhaust into a chimney, under any enclosed house floor (crawl space), or into an attic, since the accumulated lint could create a fire hazard or moisture could cause damage. Never terminate the exhaust into a common duct or plenum with a 0 56 ft. 42 ft. 30 ft. 22 ft. kitchen exhaust, since the combination of lint and grease could create a fire hazard. Spacemaker ® Model WSM2700T Spacemaker ® Models 1 2 3 0 46 ft. 34 ft. 32 ft. 43 ft. 36 ft. 28 ft. 18 ft. 36 ft. 22 ft. 16 ft. 10 ft. 30 ft. 14 ft. 10 ft. 5 ft. 24 ft. Exhaust ducts should be terminated in a dampered wall cap to prevent back drafts, bird nesting, etc. The wall cap must also be located at least 12” above the ground or any other obstruction with the opening pointed down. Other terminations, such as louvered wall boxes, are acceptable provided they are equivalent to a 4” openi...

Questo manuale è adatto anche per i modelli :
Lavatrici - GE Spacemaker DSKP233EW (52.3 kb)
Lavatrici - GE Spacemaker DSKS433A (52.3 kb)
Lavatrici - GE Spacemaker DSKS433EAWW (52.3 kb)
Lavatrici - GE Spacemaker DSKS433EW (52.3 kb)

Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie