Noisy 5a. Not leveled. 5a. Adjust levelling legs, tighten lock nuts. 5b. Foreign object in tub. 5b. Check tub, remove object. 5c. Shock Absorber. 5c. Check that attachment bolts are tight. 6. Vibrates. 6a. Shipping brackets attached. 6a. Remove & store shipping brackets. 6b. Unstable floor 6b. Remove carpeting, move to abeter location, or install underlayment. 6c. Not leveled properly 6c. Adjust levelling legs, tighten lock nuts. 7. Water leaks from detergent drawer 7a. Not leveled. 7a. Adjust levelling legs, tighten lock nuts. 7b. Spinning with water in tub. 7b. Not draining. See Won't drain 7c. Electronic Control Module 7c. Test signals at Control Module. See Testing Electronic Control. If correct, replace control module. If tests between terminals 1-7 fail, replace timer. If tests on terminals 8, 9 or 12-15 fail, replace motor. 7d. Motor (tachometer). 7d. Check tachometer resistance. See Testing the Drive Motor. 8. Timer doesn't advance 8a. Water supply off. 8a. Check water pressure at inlet valve connections. 8b. Filling interrupted. 8b. See Won't Fill. 8c. Timer. 8c. Test timer motor resistance: 2000 ohms max. Set to different cycle (e.g. Delicates) & check timer function different cycle (e.g. Delicates). 9. Tub rotates one direction only during wash and dry cycles 9a. Electronic Control Module 9a. Test signals at Control Module. See Testing Electronic Control. If correct, replace control module. If tests between terminals 1-7 fail, replace timer. If tests on terminals 8, 9 or 12-15 fail, replace motor. 9b. Timer. 9b. See above. 10. Water flows into tub with machine off. 10a. Water inlet valves leaking. 10a. Identify leaking valve. Remove and clean by backflushing to remove foreign material. Replace valve if cleaning does not correct the problem. 4 Problem Possible Cause Repair Procedure 11. Machine overfills. 11a. Pressure Switch. 11a.Unplug unit. With excessive water still in tub, check for continuity between terminals 21 and 22. Drain machine, then replace pressure switch if test indicates continuity. 11b. Pressur Switch Hose. 11b. Drain machine, then replace pressure kinked or leaking switch hose. 12. Door won't open. 12a. Door lock enabled. 12a. Water in tub. See Won't drain. 12b. Pressure Switch. 12b. Unplug unit, wait 2 minutes to release door lock. Test switch with pressure hose off. There should be no continuity between terminals 11&13. 13. Clothes wet at end of wash cycle. 13a. Water in tub. 13a. See Won't drain. 13b. Inadequate final spin. 13b. See Won't Spin. Problem Possible Cause Repair Procedure Dry Cycle 1. No tumble action. 1a. No power input. 1a. Check that cord is plugged in, and circuit breaker or, if fuse is OK. Test unit power switch. 1b. Door not closed. 1b. Close door firmly, so that it latches tightly. 1c. Door switch. 1c. Close the door. Test for 115 vac between terminal a of the dryer timer and the common (low) side of the water inlet valves. 1d. Dry timer. 1d. Set dry timer to 60 minutes. Test for 115 vac between terminal al of the dryer timer and the common (low) side of the water inlet valves. 1e. Belt. 1e. Check belt, adjust tension. 1f. Electronic Control 1f. Test signals at the Control Module. See Testing the Control Module. If correct, replace the control module. If tests on terminals 1 to 7 fail, replace timer. Tests on terminals 8, 9 or 12 through 15 fail, replace motor. 1g. Motor. 1g. Check motor resistance. See Testing the Drive Motor. 2. Clothes cold and damp at the end of the dry cycle. 2a. Timer not advanced beyond the cool-down period. 2a. Set dryer timer for times longer than 15 minutes. 5 Problem Possible Cause Repair Procedure 2b. Blower inoperative. 2b. Check for 115 vac at the blower motor terminals. Check motor resistance: 10 ohms maximum. 2c. Thermostats open. 2c. Check for continuity, at room temperature. 2d. Thermal fuse open. 2d. Check for continuity. 2e. Heating elements. 2e. Check resistance: 25 ohms maximum open. 2f. Dryer timer. 2f. Test for 115 vac between either terminal of 88° C thermostat & either terminal of 110° C thermostat. 3. Clothes hot and damp at the end of the dry cycle. 3a. Blocked filter. 3a. Remove, clean, and replace filter. 3b. *No cold water supply. 3b. Cold water reuired for dryer to function properly. 3c. * Machine not leveled. 3c. Condenser water flow disturbed. Level unit and retest. 3d. Blower impeller. 3d. Remove and clean. Also check to see if condensing channel is clogged with lint. 3e. * Condenser water valve inoperative. 3e. Test for 110 vac across the valve terminals. If present, valve may be defective. 3f. * Blower housing to Tub Seals mismatched. 3f. Disassemble blower housing from tub. Ensure that seals are positioned properly & reassemble. 4. Long drying time. 4a. High suds detergent. 4a. Use Equator detergent, or other low-suds brand. Excessive detergent. Measure detergent, using 2 tablespoons or 1/8 cup maximum. 4b. Hot and cold water hoses reversed. 4b. Connect hoses to the proper inlet valves. 4c. Dryer sectio...

Questo manuale è adatto anche per i modelli :
Lavatrici - EZ 1500 (1.27 mb)
Lavatrici - EZ 3600 C/CEE (1.27 mb)

Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie