Facilità d'uso


Air Consumption: The EHF1838K requires 1.94 cubic feet per minute or C.F.M. (54.93 liters per minute or LT/MIN) of free air at 80PSI (5.6 kg/cm2) to operate at a rate of 60 fasteners per minute. The LHF2025K requires 1.90 cubic feet per minute or C.F.M. (53.8 liters per minute or LT/MIN) of free air at 80PSI (5.6 kg/cm2) to operate at a rate of 60 fasteners per minute. To determine the appropriately sized air compressor, take the actual rate at which the tool will be run and compare the required C.F.M. (LT/MIN) to the compressors free air delivery (C.F.M./ LT/MIN) at 80 PSI (5.6 kg/cm2). For example, if your fastener usage averages 30 fasteners per minute, you need 50% of the tools C.F.M. required to operate the tool at the rate of 60 fasteners per minute. In this case, be sure that your air compressor can deliver a minimum of 0.97 C.F.M. (27.47 LT/MIN) at 80 PSI (5.6 kg/cm2) for optimum performance. FASTENER SPECIFICATIONS Tool Model Fastener Type Fastener SKU Crown Width Gauge Length SX50351G 18 1” (25mm) 7/32” SX50351-1/8G 18 1-1/8” (28mm) 7/32” SX50351-3/16G 18 1-3/16” (30mm) 7/32” EHF1838K SX50351-1/4G 18 1-1/4” (32mm) 7/32” SX50351-3/8G 18 1-3/8” (35mm) 7/32” Staples SX50351-1/2G 18 1-1/2” (38mm) 7/32” SB97-1GLS 3/16” 20 1” (25mm) LHF2025K Staples * Stainless steel fasteners also available in certain sizes. Visit for further details. NOTE: BOSTITCH tools have been engineered to provide superior customer satisfaction and are designed to achieve maximum perfomance when used with precision BOSTITICH fasteners engineered to the same exacting standards. BOSTITCH cannot assume responsibility for product performance if our tools are used with fasteners or accessories not meeting the specific requirements established for genuine BOSTITCH fasteners and accessories. -5- AIR SUPPLY AND CONNECTIONS Do not use oxygen, combustible gases, or bottled gases as a power source for this tool as tool may explode, possibly causing injury. FITTINGS: Install a male plug on the tool which is free flowing and which will release air pressure from the tool when disconnected from the supply source. HOSES: Air hoses should have a minimum of 150 p.s.i. (10.6 kg/cm2) working pressure rating or 150 percent of the maximum pressure that could be produced in the air system. The supply hose should contain a fitting that will provide “quick disconnecting” from the male plug on the tool. SUPPLY SOURCE: Use only clean regulated compressed air as a power source for this tool. NEVER USE OXYGEN, COMBUSTIBLE GASES, OR BOTTLED GASES, AS A POWER SOURCE FOR THIS TOOL AS TOOL MAY EXPLODE. REGULATOR: A pressure regulator with an operating pressure of 0 -125 p.s.i. (0 -8.79 kg/cm2) is required to control the operating pressure for safe operation of this tool. Do not connect this tool to air pressure which can potentially exceed 200 p.s.i. (14 kg/cm2) as tool may burst, possibly causing injury. OPERATING PRESSURE: Do not exceed recommended maximum operating pressure as tool wear will be greatly increased. The air supply must be capable of maintaining the operating pressure at the tool. Pressure drops in the air supply can reduce the tool’s driving power. Refer to “TOOL SPECIFICATIONS” for setting the correct operating pressure for the tool. FILTER: Dirt and water in the air supply are major causes of wear in pneumatic tools. A filter will help to get the best performance and minimum wear from the tool. The filter must have adequate flow capacity for the specific installation. The filter has to be kept clean to be effective in providing clean compressed air to the tool. Consult the manufacturer’s instructions on proper maintenance of your filter. A dirty and clogged filter will cause a pressure drop which will reduce the tool’s performance. QuickConnectPlugQuickDisconnectPlug -6- LOADING THE EHF1838K & LHF2025K EYE PROTECTION which conforms to ANSI specifications and provides protection against flying particles both from the FRONT and SIDE should ALWAYS be worn by the operator and others in the work area when connecting to air supply, loading, operating or servicing this tool. Eye protection is required to guard against flying fasteners and debris, which could cause severe eye injury. The employer and/or user must ensure that proper eye protection is worn. Eye protection equipment must conform to the requirements of the American National Standards Institute, ANSI Z87.1 and provide both frontal and side protection. NOTE: Non-side shielded spectacles and face shields alone do not provide adequate protection. TO PREVENT ACCIDENTAL INJURIES: • Never place a hand or any other part of the body in fastener discharge area of tool while the air supply is connected. • Never point the tool at anyone else. • Never engage in horseplay. • Never pull the trigger unless nose is directed at the work. • Always handle the tool with care. • Do not pull the trigger or depress the trip mechanism while loading the tool. LOADING THE EHF1838K & LHF2025K 1.Depr...

Questo manuale è adatto anche per i modelli :
Chiodatrici - LHF2025K (1.14 mb)

Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie