Istruzioni per l'uso Hotpoint, Modello NVL333GYAA

Produttore : Hotpoint
File Size : 38.86 kb
File Nome :
Lingua di insegnamento: en
Vai a scaricare



Facilità d'uso


R Listed by Underwriters Laboratories Specification Created 7/99 NVL333GYWW - Hotpoint Dryer Exhausting Information— Best Performance Domestic Dryer Models B 2-1/2 A Maximum Length of 4" Maximum Length of 4" Dia. Rigid Metal Duct Dia. Flexible Metal Duct Exhaust Hood Type Exhaust Hood Type Number Cat. No. Cat. No. of WX8X59 WX8X59 B B 90° (Preferred) (Preferred) 2-1/2" 2-1/2" Turns A A Opening Opening 4" Opening 4" Opening Super & Extra-Large Capacity Models All Electric Dryers Super & Extra-Large Capacity Models All Gas Dryers 0 1 2 3 4 0 1 2 3 90 ft. 60 ft. 45 ft. 35 ft. 25 ft. 45 ft. 35 ft. 25 ft. 15 ft. 60 ft. 45 ft. 35 ft. 25 ft. 15 ft. 30 ft. 20 ft. 10 ft. — 55 ft. 40 ft. 30 ft. 20 ft. 15 ft. 30 ft. 20 ft. 10 ft. — 45 ft. 30 ft. 20 ft. 15 ft. 10 ft. 15 ft. 10 ft. — — Large Capacity Electric and Gas Dryers 0 1 2 3 4 60 ft. 52 ft. 44 ft. 32 ft. 28 ft. 48 ft. 40 ft. 32 ft. 24 ft. 16 ft. 30 ft. 22 ft. 14 ft. — — 18 ft. 14 ft. 10 ft. — ft. — ft. Special Installation Requirements Alcove or Closet Installation: • If your dryer is approved for installation in an alcove or closet, it will be stated on a label on the dryer back. • The dryer MUST be exhausted to the outside. • Minimum clearances between dryer cabinet and adjacent walls or other surfaces are: 0” either side 3” front and rear • Minimum vertical space from floor to overhead cabinets, ceilings, etc. is 52”. • Closet doors must be louvered or otherwise ventilated and must contain a minimum of 60 sq. in. of open area equally distributed. If this closet contains both a washer and a dryer, doors must contain a minimum of 120 sq. in. of open area equally distributed. • The closet should be vented to the outdoors to prevent gas pocketing in case of a gas leak in the supply line. • No other fuel-burning appliance shall be installed in the same closet with the dryer. Bathroom or Bedroom Installation: • The dryer MUST be exhausted to the outdoors. • The installation must conform with the local codes, or in the absence of local codes, with the National Fuel Gas Code, ANSI Z223. Minimum Clearances other than Alcove or Closet Installation: • Minimum clearances to combustible surfaces 0” both sides 3” rear Specification Created 7/99 For complete information, see installationinstructions packed with your dryer. Important Note: GE Kit Number WE14X70 needed when converting rear Ducting Materials: For best performance, this dryer should be vented with 4” diameter duct cannot be used, then “flexible all metal” venting can be used, duct length. Exhaust Length Calculation: 1. Determine the number of 90° turns needed for your installation. If you exhaust to the side or bottom of dryer, add one turn. 2. The maximum length of 4’ rigid (aluminum or galvanized) duct which can be tolerated in the table. The maximum length for flexible ducts are less than for rigid duct. A turn of 45° or less may be ignored. Two 45° turns within the duct length should be treated as a 90° elbow. A turn over 45° should be treated as ...

Questo manuale è adatto anche per i modelli :
essiccatori - NVL333EYAA (38.86 kb)
essiccatori - NVL333EYWW (38.86 kb)
essiccatori - NVL333GYWW (38.86 kb)

Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie