|
Facilità d'uso
Gas supply pressure testing • The dryer must be disconnected from the gas supply piping system during pressure testing at pressures greater than _/_psi. _®TEFLON is a registered trademark of E.I. Du Pont De Nemours and Company. Dryer gas pipe • The gas pipe that comes out through the rear of your dryer has a %" male pipe thread. B (15.9 cm) A. Y2" NPT gas supply line B. %" NPT dryer pipe *NOTE: If the dryer is mounted on a pedestal, the gas pipe height must be an additional 10" (25.4 cm) from the floor. For a garage installation, the gas pipe height must be an additional 18" (46 cm) from the floor. Fire Hazard Use a heavy metal vent. Do not use a plastic vent. Do not use a metal foil vent. Failure to follow these instructions can result in death or fire. WARNING: To reduce the risk of fire, this dryer MUST BE EXHAUSTED OUTDOORS. IMPORTANT: Observe all governing codes and ordinances. The dryer exhaust must not be connected into any gas vent, chimney, wall, ceiling or a concealed space of a building. If using an existing vent system • Clean lint from the entire length of the system and make sure exhaust hood is not plugged with lint. • Replace any plastic or metal foil vent with rigid or flexible heavy metal vent. • Review Vent system chart. Modify existing vent system if necessary to achieve the best drying performance. If this is a new vent system Vent material • Use a heavy metal vent. Do not use plastic or metal foil vent. • 4" (10.2 cm) heavy metal exhaust vent and clamps must be used. DURASAFF Mventing products are recommended. 4" (lO.2cm) heavymetal exhaust vent DURASAFF Mvent products can be purchased from your dealer. For further information, please call 1-800-4-MY-HOME ®(1-800-469-4863} or visit our website at Rigid metal vent • For best drying performance, rigid metal vents are recommended. • Rigid metal vent is recommended to avoid crushing and kinking. Flexible metal vent • Flexible metal vents are acceptable only if accessible for cleaning. • Flexible metal vent must be fully extended and supported when the dryer is in its final location. • Remove excess flexible metal vent to avoid sagging and kinking that may result in reduced airflow and poor performance. • Do not install flexible metal vent in enclosed walls, ceilings or floors. Elbows 45° elbows provide better airflow than 90° elbows. Good Better Clamps The angled hood style (shown here) is acceptable. • Use clamps to seal all joints. • Exhaust vent must not be connected or secured with screws or other fastening devices that extend into the interior of the duct. Do not use duct tape. (6.4 crn) An exhaust hood should cap the vent to keep rodents and insects from entering the home. Clamp Exhaust hood must be at least 12" (30.5 cm) from the ground or any object that may be in the path of the exhaust (such as Exhaust flowers, rocks or bushes, snow line, etc.). Recommended hood styles are shown here. • Do not use an exhaust hood with a magnetic latch. Improper venting can cause moisture and lint to collect indoors, which may result in: [] Moisture damage to woodwork, furniture, paint, wallpaper, carpets, etc. _4 4 (1_-4"cm) [] Housecleaning problems and health problems. (10.2 cm) A. Louvered hood style B. Box hood style Alternate installations for close clearances Choose your exhaust installation type Recommended exhaust installations Typical installations vent the dryer from the rear of the dryer. Other installations are possible. B A ..... ................. F ................................... G A. Dryer B. Elbow C. Wall D. Exhaust hood E, Clamps F. Rigid metal or flexible metal vent G. Vent length necessary to connect elbows H. Exhaust outlet Optional exhaust installations Fire Hazard Cover unused exhaust holes with the following kit: 279818 (white) Contact your local dealer. Failure to follow these instructions can result in death, fire, electrical shock, or serious injury. This dryer can be converted to exhaust out the right side, left side, or through the bottom. Contact your local dealer to have the dryer converted. A B A. Standard rear offset exhaust installation B. Left or right side exhaust installation C. Bottom exhaust installation (not an option with pedestal installations) Venting systems come in many varieties. Select the type best for your installation. Two close-clearance installations are shown. Refer to the manufacturer's instructions. i/ I II A B A. Over-No-top installation (also available with one offset elbow) B. Periscope installation NOTE: The following kits for close clearance alternate installations are available for purchase. For further information, please call 1-800-4-MY-HOME ®(1-800-469-4663}. • Over-the-Top Installation: Part Number 26-49900 • Periscope Installation (For use with dryer vent to wall vent mismatch): Part Number 26-49901 -Less than 5" (12.7 cm) mismatch Part Number 26-49908 -5" (12.7 cm) to 18" (45.72 cm) mismatch Part Number 26-49904 -18" (45.72 cm) to 29" (73.66 cm) mismatch Part Num...
Questo manuale è adatto anche per i modelli :essiccatori - 110.9756 (3.55 mb)
essiccatori - 9758 (3.55 mb)