Produttore : Cissell
File Size : 341.47 kb
File Nome : 35083da2-dadc-49e3-a9b4-fe6b1216213a.pdf
|
Facilità d'uso
83” (208 cm) L x 45” (113 cm) W x 61” (153 cm) H Export Crating .............................................. 131.8 cu. ft. (3.73 M.) Basket RPM ................................................. Reversing 40-3.2 reversals per minute. Non-reversing - 40. * Input ratings as shown are for elevations up to 2000 ft. (610 M). For higher elevations, ratings should be reduced 4% for each 1000 feet (305M) above sea level. Page 12 Motor List DOUBLE MOTOR MODELS Motor No. Voltage Hz. Phase Basket/Fan HP Amps RPM MTR203 115/200/230 60 1 B 1 10.4/5.2 1725 MTR212 200/230/460 60 3 B 1 3.8/1.9 1725 MTR206 110/220 50 1 B 1 12/6 1425 MTR104 240/415 50 3 B 1 3.1/1.8 1425 MTR104 220/380 50 3 B 3/4 2.6/1.5 1425 MTR104 220/380 60 3 B 3/4 2.4/1.4 1725 MTR104 200/346 50 3 B 3/4 2.6/1.5 1425 MTR101 575 60 3 B/F 1 1.7 1725 MTR209 115/208-230 60 1 F 1/3 5.2/2.6 1725 MTR218 208/230/460 60 3 F 1/3 1.6/.80 1725 MTR184 240/415 50 3 F 1/3 1.6/.90 1425 MTR187 220/380 50 3 F 1/3 1.6/.91 1425 MTR187 220/380 60 3 F 1/3 1.5/.80 1725 MTR187 200/346 50 3 F 1/3 1.5/.80 1425 SINGLE MOTOR MODELS Motor No. Voltage Hz. Phase HP Amps RPM MTR246 115/208-230 60 1 1 11.3/5.65 1725 MTR247 208-230/460 60 3 1 3.8-4.2/2.1 1725 MTR248 575 60 3 1 1.8 1725 MTR249 240/415 50 3 1 3.8/2.2 1425 MTR250 240 50 1 1 7.3 1425 MTR266 220/380 50 3 1 3.5/2.0 1425 MTR266 220/380 60 3 1 3.2/1.8 1725 MTR266 200/346 50 3 1 3.2/1.8 1425 Page 13 General Information & Grounding Instructions GENERAL INFORMATION CISSELL COOL-DOWN ELECTRICAL CONNECTIONS The Cissell Dryer is so designed that when an operator opens the dryer door, the basket and exhaust fan stops. You can expect fast drying from a Cissell Laundry Dryer. Hot, dry air is properly and effectively moved through the basket and exhausted through a lint trap to the atmosphere. The Cissell Dryer comes equipped with an inclined, self-cleaning lint screen. In this system, lint accumulates on the underside of the screen until a blanket approximately 1/4” thick is formed. This blanket of lint will fall from the screen to the bottom of the dryer cabinet and should be removed daily, or as required, to prevent an over accumulation. Permanent press, durable press and other modern day fabrics require the care that your Cissell Laundry Dryers now provide. At the end of the drying cycle, determined by the time and temperature; single timer, a thermostatic control, automatically takes over and continues the rotation of the fan and basket without heat, until the garment load reaches a safe, cool temperature. This function is performed at the end of each drying cycle, and because it’s controlled by the heat retained in the garments after the normal drying period, its time can extend from one minute, up to five minutes. The thermo-cool cycle is never too long or too short. Always the exact minimum time required to reduce the temperature of the garment load to a safe and cool handling temperature. Dryers must be electrically grounded by a separate #14 or larger green wire from the grounding terminal within the service connection box to a cold water pipe, or through the fourth green wire properly grounded and connected to the grounding terminal. In all cases, the grounding method must comply with local electrical code requirements; or in the absence of local codes, with the National Electrical Code as ANSI/NFPA 70 (Latest Edition). See wiring diagram furnished with dryer. Your Cissell Dryer is completely wired at the factory and it is only necessary for the electrician to connect the power leads to the wire connectors within the service connection box on the rear of the dryer. Do not change wiring without consulting factory as you may void the factory warranty. DO NOT CONNECT THE DRYER TO ANY VOLTAGE OR CURRENT OTHER THAN THAT SPECIFIED ON THE DRYER RATING PLATE. (Wiring diagram is located on rear wall of dryer.) Page 14 Grounding Instructions (Illustration) Page 15 Piping Recommendations PIPING RECOMMENDATIONS STEAM HEATING UNITS 1. Trap each dryer individually. Always keep the trap clean and in good working condition. 2. When dryer is on the end of a line of equipment, extend header at least 4 feet beyond dryer. Install globe valve, union, check valve and by-pass trap at end of line. If gravity return to boiler, omit trap. 3. Insulate steam supply and return line for safety ofoperator and safety while servicing dryer. 4. Keep dryer in good working condition. Repair or replace any worn or defective parts. 1. Keep steam coils clean. 2. Check periodically and clean as often as required. 3. Remove lint and dirt accumulation from coil fins periodically as dirty lint-laden coil fins decrease the efficiency of steam- heated dryers. Page 16 Gas Piping GAS PIPING INSTALLATION Check gas rating plate for type of gas to equip the dryer. Check for altitude elevation of the dryer. Check utility for proper installation of gas supply line and gas pressure. NATURAL GAS ONLY Check the gas pressure inlet supply to dryer, 11” W.C. Pressure maximum. Check the ...
Questo manuale è adatto anche per i modelli :essiccatori - L36URD36G (341.47 kb)
essiccatori - L36URD36S (341.47 kb)
essiccatori - L36URS36E (341.47 kb)
essiccatori - L36URS36G (341.47 kb)