Ramping is designed to help you adjust to an increase in pressure gradually, and enhance your comfort. . English Stopping Treatment To stop treatment at any time, remove your mask and press . If your clinician has enabled SmartStart, simply remove your mask and treatment will end. Changing the Settings on your S8 II Device You can change settings (such as Ramp Time, EPR Level) on the S8 II by using the keypad and LCD. When the device is in standby mode you can display a series of screens (a menu) on the LCD screen in order to view and change the settings for a particular function. The Standard Menu Your clinician will have enabled the menu on your S8 Series II device. The picture shows the standard menu in each mode. CPAP AUTOSET RAMP: 10min menu WELCOME >>>>>> EPR LEVEL: 1 change exit MASK: ULTRA change exit exit SW: SX4800100 USED HRS: 08000 exit USAGE: 1000/1068 exit * SETTLING: 10min menu WELCOME >>>>>> MASK: ULTRA change exit exit SW: SX4800100 USED HRS: 08000 exit USAGE: 1000/1068 exit EPR LEVEL: 1 change exit * * Only displayed if access set by clinician. Note: The AutoSet menu is available on the S8 AutoSet II only. To enter the standard menu from the standby (RAMP or SETTLING) screen, press . Changing the Settings on your S8 II Device You can use this menu to change the: • Expiratory Pressure Relief (EPR) settings Your clinician may have set up your device to deliver EPR. This can be used to help ease any discomfort you may experience when breathing out during treatment. There are four settings: OFF (no EPR); 1 (lowest EPR); 2; and 3 (highest EPR). The EPR LEVEL screen only appears if your clinician has enabled access to the EPR settings. To change the EPR level, select . Press or until you see the setting that you require. • Mask type – see page 3. You can also view the total number of hours of treatment (USED HRS); the number of sessions that the S8 Series II device was used in a usage period (USAGE); and the current software version (SW). English The Detailed Menu Your clinician may have enabled a detailed menu on your S8 Series II device. The picture shows the detailed menu in each mode. RAMP: 10min menu WELCOME >>>>>> SETTINGS enter exit SETTLING: 10min menu WELCOME >>>>>> EPR LEVEL: 1 change exit MASK: ULTRA change exit TUBE LENGTH: 2m change exit HUMID: NONE change exit SMARTSTART: ON change exit LEAK ALERT: OFF change exit CPAP AUTOSET MASK: ULTRA change exit TUBE LENGTH: 2m change exit HUMID: NONE change exit SMARTSTART: ON change exit LEAK ALERT: OFF change exit AUTOSET CPAP USED HRS: 08000 exit USAGE: 1000/1068 exit RESULTS enter exit SERVICING enter exit OPTIONS enter exit LANG: ENGLISH change exit SN: 12345678912 exit PCB: 123456789123 4567 exit SW: SX4800100 exit SMART DATA enter exit SMART DATA enter exit AUTO APPEAR: OFF change cancel EPR LEVEL: 1 change exit * * Only displayed if access set by clinician. ** * * Note: The AutoSet menu is available on the S8 AutoSet II only. To enter the detailed menu from the standby (RAMP or SETTLING) screen, press . The SETTINGS menu screen is displayed. Changing the Settings on your S8 II Device Settings Menu Select on the Settings menu to access the options in this menu. You can use the Settings menu to change the: • Expiratory Pressure Relief (EPR) settings – see page 6. • Mask type – see page 3. • Tube length Scroll to TUBE LENGTH and select . Press or until you see the setting that you require. • Front cap You can set up your device to use the front cap accessory. Scroll to HUMID and select . Press or until you see the setting that you require. • SmartStart settings SmartStart enables your device to start automatically when you breathe into the mask. Scroll to SMARTSTART and select . Press or to change the option to ON or OFF. • Leak alert settings Leak alert indicates when a high mask leak is present. Scroll to LEAK ALERT and select . Press or to change the option to ON or OFF. Results Menu Select on the Results menu to access the options in this menu. You can use the Results menu to view the total number of hours of treatment (USED HRS) and the number of sessions that the S8 AutoSet II was used in a usage period (USAGE). Note: Your clinician may have customized your device to display Smart Data. Contact your clinician for further details about Smart Data. Options Menu Select on the Options menu to access the options in this menu. You can use the Options menu to change the language setting. Scroll to LANG and select . Press or until you see the setting that you require. Servicing Menu Select on the Servicing menu to access the options in this menu. You can use the Servicing menu to view the device system information. English Messages on the S8 Series II LCD Your clinician may have set your S8 Series II device to remind you about important events, such as when to replace your mask, when to insert your Data Card (if your device is Data Card enabled) and so on. The reminder message is displayed on the LCD and is visible if the device is not del...