|
Facilità d'uso
PC Input Terminals Connection Computer signals which can be input are those with a horizontal scanning frequency of 15 to 110 kHz and vertical scanning frequency of 48 to 120 Hz. (However, the image will not be displayed properly if the signals exceed 1,200 lines.) Some PC models cannot be connected to the set. There is no need to use an adapter for computers with IBM PC/AT compatible D-sub 15P terminal. The maximum resolution: 1,280 . 1,024 If the display resolution exceeds these maximums, it may not be possible to show fine detail with sufficient clarity. Signal Names for D-sub 15P Connector Pin No. Signal Name Pin No. Signal Name Pin No. 1 3 452 678 9 10 1514131211 Signal Name NC (not connected) NC HD/SYNC VD Pin Layout for PC Input Terminal GND (Ground) GND (Ground) NC Technical Information R GND (Ground) G GND (Ground) B GND (Ground) NC (not connected) NC (not connected) FAQs, Technical Information (Continued) DATA/MTI (RJ11) terminal connection A standard 6 pin RJ-11C connector is used to provide a connection between the MTI equipment and the TV set. Both the MTI terminal and TV are equipped with FCC-66 style (RJ-11C) jacks. Each of these jacks shall accept a 6 contact plug Molex P/N 90075-0007 or equivalent. External TA Multiple Television Interface(MTI) Pin layout for RJ-11C terminal Interface signals on the interface 123456 1 Clock 6 TV 2 MTI Data 5 MTI 3 Open 4 N/C 4 TV Data 3 TV 5 Ground 2 Common 6 IR Data 1 TV TV Connector Pin Signal MTI terminal Connector Pin Signal source Internal TA Compatible with LodgeNet game controller(DATA) SERIAL CRTL (RS232C (M3)) terminal connection PC Control of the TV The TV can be controlled by a personal computer when connected through an RS232C cable (not supplied). The computer will require software which allows sending and receiving of control data through its SERIAL port. Please see required parameters and commands below. Pin layout and signal name for SERIAL CTRL terminal Tx GNDTx_TV (Transmission of TV side) Rx_TV (Reception of TV side) GND TV set Rx ¦Basic format for control data Communication parameters Signal level RS-232C compliant Synchronization method Asynchronous Baud rate 9600 bps Parity None Character length 8 bits Stop bit 1 bit Flow control - The transmission of control data from the external device starts with a STX signal, followed by the command, the parameters, and lastly an ETX signal in that order. If there are no parameters, then the parameter signal does not need to be sent. STX : ETX Start (02 h): 1 byte Command: 3 byte (fixed) Colon: 1 byte Parameter: 5 bytes maximum (Length depends on Command) End (03 h): 1 byteColon and Parameter are only sent when necessary C1 C2 C3 P1 P2 P3 P4 P5 * Please see p. 35 regarding Commands and Parameters. Notes With standby mode, this TV responds to “PON” and “QPW” commands only. Wait for the response of the first command to come from this unit before sending the next command. If multiple commands are transmitted, be sure to keep intervals of 250msec. Send the command again when the call back command is unusual. If an incorrect command is sent by mistake, this TV will send an “ER401” or “ER402” command back to the computer. This TV does not respond for 15 seconds when “PON” or “POF” commands are transmitted. Send “EXT” commands before sending “IMS:**” commands. SERIAL CTRL (RS232C) command list SERIAL CTRL (RS232C) command list Functions of gray part are not available during online mode. FAQs, Technical Information Control Command Inquiry Command Call back Command Parameter STANDARD CONTROL POWER ON PON QPW QPW:* “0”(OFF)/“1”(ON) POWER OFF POF VOL level AVL:** QAV QAV:*** “000” ~ “100”VOL UP AUU VOL DOWN AUD MUTE AMT:* QAM QAM:* “0”(NO MUTED)/ “1”(MUTED)MUTE(Toggle) AMT ASPECT DAM:**** QAS QAS:**** “ZOOM”/“FULL”/“JUST” /“NORM” (4:3)/“HFIL”ASPECT (Toggle) DAM INPUT SELECT CH UP CHU ---- -- CH DOWN CHD TV IMS:TV QMI QMI:** “TV” Compornent IMS:C1 “C1” Video 1 IMS:V1 “V1” Video 2 IMS:V2 “V2” HDMI 1 IMS:H1 “H1” HDMI 2 IMS:H2 “H2” HDMI 3 IMS:H3 “H3” PC IMS:PC “PC” SD IMS:SP “SP” (Toggle) IMS --PICTURE MODE Vivid VPC:VVT QPC QPC:*** “VVT” Standard VPC:STD “STD” Custom *1 /Photo *2 VPC:CST “CST” CHANNEL COMMAND LAST CH LCH ---- -- OTHER COMMAND Information INF ---- -- -- QIF QIF:***** 480i/480p/576i/576p/720P/1080i/1080p MENU FUNCTION MENU MEN ---- -- SELECT SEL RETURN RTN EXIT EXT ARROW LEFT ARL ARROW RIGHT ARR ARROW UP ARU ARROW DOWN ARD *1 Except SD mode *2 Only SD mode FAQ Before requesting service or assistance, please follow these simple guides to resolve the problem. If the problem still persists, please contact your local Panasonic dealer or Panasonic Service Center for assistance. White spots or shadow images (noise) Check the position, direction, and connection of the antenna. Interference or frozen digitalchannels (intermittent sound) Change the direction of antenna for digital channels. Check “Signal meter” (p. 25). If the signal is weak, check the antenna and consult your local dealer. The LCD panel ...
Questo manuale è adatto anche per i modelli :TV - TH-37LRU20 (2.33 mb)
TV - TH-42LRU20 (2.33 mb)