|
Facilità d'uso
• The computer shown is for example purposes only. • Additional equipment and cables shown are not supplied with this set. The SERIAL terminal conforms to the RS-232C interface specifi cation, so that the Plasma Display can be controlled by a computer which is connected to this terminal. The computer will require software which allows the sending and receiving of control data which satisfi es the conditions given below. Use a computer application such as programming language software. Refer to the documentation for the computer application for details. Basic format for control data The transmission of control data from the computer starts with a STX signal, followed by the command, the parameters, and lastly an ETX signal in that order. If there are no parameters, then the parameter signal does not need to be sent. Start (02h) 3-character command (3 bytes) Colon Parameter(s) (1 - 5 bytes) End (03h) STX C1 C2 C3 : P1 P2 P3 P4 P5 ETX Notes: • If multiple commands are transmitted, be sure to wait for the response for the fi rst command to come from this unit before sending the next command. • If an incorrect command is sent by mistake, this unit will send an “ER401” command back to the computer. • S1A and S1B of Command IMS are available only when a dual input terminal board is attached. Pin layout for SERIAL Terminal Command Command Parameter Control details PON None Power ON POF None Power OFF AVL ** Volume 00 - 63 AMT 0 Audio MUTE OFF 1 Audio MUTE ON IMS None SL1 S1A S1B VD1 YP1 HM1 DV1 PC1 Input select (toggle) SLOT input (SLOT INPUT) SLOT input (SLOT INPUT A) SLOT input (SLOT INPUT B) VIDEO input (VIDEO) COMPONENT/RGB IN input (COMPONENT) HDMI input (HDMI) DVI-D IN input (DVI) PC IN input (PC) DAM None ZOOM FULL JUST NORM SJST SNOM SFUL ZOM2 Screen mode select (toggle) ZOOM (For Video/SD/PC signal) FULL JUST (For Video/SD signal) 4:3 (For Video/SD/PC signal) JUST (For HD signal) 4:3 (For HD signal) H-FILL (For HD signal) ZOOM (For HD signal) With the power off, this display responds to PON command only. Communication parameters Signal level RS-232C compliant Synchronization method Asynchronous Baud rate 9600 bps Parity None Character length 8 bits Stop bit 1 bit Flow control - Signal names for D-sub 9P connector Pin No. Details 2 R X D 3 T X D 5 GND 4 • 6 Non use 7 8 (Shorted in this set) 1 • 9 NC These signal names are those of computer specifi cations. The SERIAL terminal is used when the Plasma Display is controlled by a computer. Note: To use serial control for this unit, make sure to set the “CONTROL I/F SELECT” in the “NETWORK SETUP” menu to “RS-232C”. INPUT MENU -/ VOL +/ ENTER/ 13 Power Indicator Remote Control Sensor Power ON / OFF Connecting the AC cord plug to the Plasma Display. Connecting the plug to the Wall Outlet. Note: When disconnecting the AC cord, be absolutely sure to disconnect the AC cord plug at the socket outlet fi rst. Press the Power switch on the Plasma Display to turn the set on: Power-On. Power Indicator: Green Press the button on the remote control to turn the Plasma Display off. Power Indicator: Red (standby) Press the button on the remote control to turn the Plasma Display on. Power Indicator: Green Turn the power to the Plasma Display off by pressing the switch on the unit, when the Plasma Display is on or in standby mode. Note: During operation of the power management function, the power indicator turns orange in the power off state. Power ON / OFF PC FULL NANODRIFT English (UK) Deutsch Francais Italiano Espanol ENGLISH (US) РусскийOSD LANGUAGE SETSELECT PRESENT TIME SETUP PRESENT TIME OF DAY MON 99:99 SET PRESENT TIME OF DAY 99:99 DAY MON PRESENT TIME SETUP PRESENT TIME OF DAY MON 99:99 SET PRESENT TIME OF DAY 10:00 DAY TUE LANDSCAPE PORTRAIT DISPLAY ORIENTATION From the second time on, the below screen is displayed for a while (setting condition is an example). When first switching on the unit Following screen will be displayed when the unit is turned on for the fi rst time. Select the items with the remote control. Unit buttons are invalid. OSD LANGUAGE PRESENT TIME SETUP DISPLAY ORIENTATION 1 Select the language. 2 Set. 1 Select “DAY” or “PRESENT TIME OF DAY”. 2 Setup “DAY” or “PRESENT TIME OF DAY”. 1 For vertical installation, select “PORTRAIT”. 2 Set. Notes: • Once the items are set, the screens won't be displayed when switching on the unit next time. • After the setting, the items can be changed in the following menus. OSD LANGUAGE PRESENT TIME SETUP DISPLAY ORIENTATION 1 Select “SET”. 2 Set. Selecting the input signal Press to select the input signal to be played back from the equipment which has been connected to the Plasma Display. Input signals will change as follows: PC VIDEO COMPONENT* HDMI DVI VIDEO: Video input terminal in AV IN (VIDEO). COMPONENT*: Component or RGB input terminal in COMPONENT/RGB IN. HDMI: HDMI input terminal in AV IN (HDMI). DVI: DVI input terminal in DVI-D IN. PC: PC input terminal in PC IN. * “COMPONENT” may be displayed as “RGB” depen...
Questo manuale è adatto anche per i modelli :TV - TH-65PF20U (5.33 mb)