Log:
valutazioni - 2, GPA: 5 ( )

Istruzioni per l'uso Aube Technologies, Modello 47550

Produttore : Aube Technologies
File Size : 352.35 kb
File Nome : 47550.pdf
Lingua di insegnamento: en
Vai a scaricare



Facilità d'uso


“HE” position is for certain electric systems having a fan relay. n Furnace or Heat Pump selector (NORMAL – O – B switch) The factory position for this switch is in the NORMAL position. Leave it in this position if you have ANY system that uses gas, oil, electric, or hot water heating. If you have a single-stage Heat Pump (no emergency heat source), then slide the switch to the position that matches your Reversing Valve type. If your heat pump system has a “B” wire, slide the switch to “B” for your reversing valve that activates in HEAT mode. If your heat pump system has an “O” wire, slide the switch to “O” for your reversing valve that activates in COOL mode. F°/C° selector 12 Hr./24 Hr. Recovery Span selector (SW5) selector selector (SW7) (SW6) (SW8) HG – HE switchNormal – O – B – switch * DEFAULT SETTING NORMAL HE HGB O SWITCH SETTING SW NAME ON * OFF SW5 F/C CELSUIS FAHRENHEIT SW6 12/24 24HOURS 12 HOURS SW7 SPAN +2F/-1F +1F/-1F SW8 RECOV. DISABLE ENABLE Feature Selector Switches: n F° / C° selector (Fahrenheit / Centigrade) – Switch 5 Your thermostat is set for F° mode from the factory. In order to change to C° mode, slide the switch to C° and press the reset button on front of the thermostat with a paper clip. NOTE: Unless the reset button is pressed, the thermostat will not change temperature mode. n 12 Hr. / 24 Hr. selector – Switch 6 Your thermostat is set for normal 12 hour (AM / PM) time format. To change to 24 hour (military) time, slide the switch to the 24 position. This change may be made without resetting the thermostat, and will automatically change the current time display and all program times in memory. n Span selector - Switch 7 Your thermostat is set to cycle at 1° F (0.5°C) above and below the set temperature. If you require slower temperature cycles in Table B Heat mode, you can select the ALT position. This may be necessary cycles too rapidly. n Auto Recovery selector - Switch 8 Your thermostat is set from the factory with the Auto Recovery Feature enabled, which complies with the EPA ENERGY STAR ® Program. If you prefer to use normal recovery, slide the switch to the ALT position. Refer to page 30 for a complete discussion of the Auto Recovery feature. Feature Selector Summary: Table B below summarizes the Feature Switches discussed above. A similar table is printed directly on the circuit board for your quick reference. Switch Setting Switch Function Alternate Standard SW 5 F° / C° Celsius Fahrenheit SW 6 12 Hr. / 24 Hr. 24 Hour 12 Hour SW 7 Span +2°F / –1°F +1°F / –1°F SW 8 Auto Recovery Disable Enable 16-17PROGRAMMING Setting Time and Day Remove the mylar label covering the LCD operating thermostat. M n Initial display after power-up or reset. The LCD will show the information AM when batteries are first installed, or after the Reset button is pressed. The 12: 00 temperature will update after a few seconds. TEMP 72 EXAMPLE: Set the thermostat to the current time of 9:43 a.m. on Saturday. Refer to Figure at right. HOUR MIN DAY RETURN ¦ During time and day setting mode, the temperature and program displays will go blank. AM 9Sa : 43 ¦ Press and hold to rapid advance to the current hour. Tap to advance one hour at a time. Note the AM / PM indicator, as the display will cycle through 24 hours. ¦ Press and hold to rapid advance to the current minute. Tap to advance one minute at a time. n Tap to advance one day at a time. AM 9Sa : 43 n When finished, press to return to the Normal time and temperature 71 TEMP display or wait 15 seconds for it to return to Normal mode automatically. Auto Programming Studies conducted by the Department estimate that setting your thermostat back 10°F during winter can reduce your fuel bill by as much as 33%. setting your thermostat up 5°F (3°C) for two during summer you can reduce your fuel bill up to 25%. Your thermostat is capable of holding up to 4 separate for each day of the week. You can program all weekdays, Monday to Friday, to the same 4 programs as shown in the table, or weekday can have a different set of 4 programs. Similarly weekend programs, Saturday and Sunday, can be the same 4 programs or each weekend day can have a different set of 4 programs. Your Hunter thermostat is pre-programmed to meet the ENERGY STAR ® guidelines for energy efficiency. Note that it is easier to modify these programs than to program the thermostat manually. AUTO n Press once. During Auto Programming, the display will change as shown. MTWTh F Sa Su PROGRAM AM PM AU TO COOL HEAT n The thermostat will be programmed for all 7 days of the week as shown below. Temperature in F° (C°) Program Number Time Heat Cool 1 6:00am 68°F (20°C) 78°F (26°C) 2 8:00am 60°F (16°C) 85°F (29°C) 3 4:00pm 68°F (20°C) 78°F (26°C) 4 10:00pm 60°F (16°C) 82°F (28°C) n Refer to Manual Programming on page 19 for instructions on entering or changing the programs. 18-19PROGRAMMING Personal Program Schedule Before programming or changing programs, use this Personal Use a pencil so you can revise you...

Questo manuale è adatto anche per i modelli :
Termostato - 47550 (352.35 kb)
Termostato - 47550 (352.35 kb)

Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie