Istruzioni per l'uso Aube Technologies, Modello Pilot-wire Programmer TH134

Produttore : Aube Technologies
File Size : 290.97 kb
File Nome : TH134.pdf
Lingua di insegnamento: en
Vai a scaricare



Facilità d'uso


... .. . . . .. . . . . . . .. . . . . ... . . . . . TH134 is an electronic six-order pilot-wire programmer that allows separate temperature control of three zones using four programs per day. The TH134 programmer has three pilot-wire outputs can be connected to thermostats or controller that accept pilot-wire signals. The TH134 programmer has a remote input to which a telephone controller (such as Aube’s CT240), a home automation system (HAS) or an energy manager can be connected. When a signal is received from any of these devices, TH134 forwards the order to the heating units. • Order buttons • Program button • Mode selection button • Return button • Zone selection button • Selection button • Time/day setting button • Display ... . • Time • Heating modes :Comfort mode : Setback modes (icon is steady in 3,5k setback; flashes in 1k and 2k setbacks) :Frost protection : Off • Operating modes -Manual mode -Auto mode • Zone selected (the letter A appears when all 3 zones are selected) • Current program (applicable to automatic mode only) The following table shows the different means of initiating an order. ... . . . . ..... . . . . . . Maintain temperature at setpoint (Comfort) No signal v v Maintain temperature at setpoint minus 3,5°C (3,5k setback) v Maintain temperature at 7°C (frost protection) v Turn heating Off (Off) v Maintain temperature at setpoint minus 1°C (1k setback) v Maintain temperature at setpoint minus 2°C (2k setback) TH134 400-134-000-A 1/27/05 1/4 TH134 400-134-000-A 1/27/05 2/4 .. .... .. .. .. The installation must be performed by an electrician. The programmer must be installed on an electrical box. .. Loosen the locking screw (the screw is captive and cannot be completely removed). .. Pull and lift the bottom of the faceplate to remove it from its mounting plate. Connect power to terminals L (line) and N (neutral). Connect the pilot wire inputs of the thermostats to terminals FP1, FP2 and FP3. .. The terminals accept wire thicknesses between 0,32 and 2,1 mm2. !"# "$% &'" (&'!)&# # ") Connect terminals 2 and 1 of the CT240 to terminals L and TEL of the programmer respectively. !"# "$%&'" (&'!)&# # ") Connect the terminals of one of the outputs of CT241 to terminals L and TEL of the programmer . &*" +, !&*+!- &' ./.!"* Connect the normally-open relay of the home automation system terminals L and TEL of the programmer. ' ")0/ *+'+0") Connect the pilot wire output of the energy manager to the TEL input of the programmer. .. Fix the mounting plate to the wall. .. Install the faceplate on the mounting plate and lock them together using the locking screw. During power-up, the TH134 perform a series of test for approximately 5 seconds. Afterwards, the programmer displays the following: .. Press . The hours display flashes. .. Set the hours using the buttons. .. Press . The minutes display flashes. .. Set the minutes using the buttons. .. Press . The day display flashes. .. Set the day using the buttons. .. Press to exit the time and day settings .. .If the “setback” and “off’ orders received by a heating unit are reversed, reverse the “Ph” and the “N” wires on the heating unit. ! Transmits the order selected via one of the order buttons. To use this mode: .. Select the zone by pressing the Zone button. (Press for 3 seconds to select all 3 zones.) .. Select the manual (Man) mode by pressing the Man/Auto button. .. Select the order by pressing the appropriate order button. The orders are sent to each zone according to the schedule programmed for that zone. To use this mode: .. Select the zone by pressing the Zone button. (Press for 3 seconds to select all 3 zones.) .. Select the Auto mode by pressing the Man/Auto button. /$+.. You can bypass the automatic mode for 2 hours. At the end of the 2 hours, the programmer returns to the automatic mode. .. Select the zone using the Zone button. (Press for 3 seconds to select all 3 zones.) .. Press the desired order button. The auto mode icon flashes during the bypass. Flashes to indicate that the time and day must be set. The programmer is in manual mode. All three zones are in comfort mode. Zone 1 is selected. . Whenever an order is received via the remote input, it becomes the active order for all 3 zones. To know which orders can be initiated by the energy manager, the phone controller or the home automa tion system, see the table on page 1. The is displayed when signals are received via the remote input. /$+.. Orders received via the remote input have priority over orders initiated via the TH134 programmer. However, you can bypass the remote input order for each zone for 2 hours. At the end of the 2 hours, the remote input order becomes active again. • Select the zone using the Zone button. (Press for 3 seconds to select all 3 zones.) • Press the desired order button. The ico...


Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie