|
Facilità d'uso
Low battery warning, Off mode The thermostat will display a low battery indication. The display will toggle between the normal display and the low battery indication. OFF Low battery warning, Cool mode The thermostat will display a low battery indication. The display will toggle between the normal Cool mode display or program Cool mode display and the low battery indication. (Program Cool Mode Low PROG COOL Battery Indication Shown) Low battery warning, Heat mode The thermostat will display a low battery indication. The display will toggle between the normal Heat mode display or program Heat mode display and the low battery indication. (Program Heat Mode Low HEAT PROG Battery Indication Shown) Combination failure (power failure & low battery). The programmable thermostats with battery backup also will indicate a combination failure; that is, both a low battery condition as well as a power failure condition. After the power is restored, the following may be indicated: Combination failure, Off mode The thermostat will display a low battery indication, as well as a power failure indication (“12:00”). The display will toggle between the low battery screen and the “12:00” screen. OFF OFF PM Combination failure, Cool mode The thermostat will display a low battery indication, as well as a power failure indication (“12:00”). The display will toggle between the low battery screen and the “12:00” screen (Non-Program Cool Mode Shown). Combination failure, Heat mode The thermostat will display a low battery indication, as well as a power failure indication (“12:00”). The display will toggle between the low battery screen and the “12:00” screen (Non-Program Heat Mode Shown). COOL COOL PM HEAT HEAT PM Troubleshooting tips. Problem Solution No display Check for 24 VAC at thermostat; display is blank when 24 VAC is not present. System fan does not Verify that wiring is correct. come on properly All thermostat buttons Verify that 24 VAC is present; unit are inoperative locks out when 24 VAC is not present. Thermostat turns on and Adjust temperature differential (see off too frequently Setting a New Temperature Differential). Program schedule activates Check time (AM/PM) set on at the wrong time thermostat (see Programming). Thermostat does not Verify that it is in Program mode; PROG follow program displays solid; check time (AM/PM); check if in Hold mode (PROG flashing). “PROG” flashes Press Hold button to remove from (in Hold mode) Hold mode. Fan runs continuously Check Fan Auto/On switch. If set to ON position, fan will run continuously. Room temperature is Verify that wall hole is plugged not correct with putty or insulation. Compressor doesn’t run There is a 3 minute time delay and a or turn off immediately 3 minute minimum run time for the when changing function compressor when it turns on/off. or setting Fan doesn’t run or turn off This is normal. On some models, the immediately when changing fan may have a 3 minute minimum function or setting run time/off time delay. “LO bat” displays on screen Replace batteries with 2 fresh “AA” alkaline batteries. Display reads “12:00 PM” Set clock/time. Problem not listed above Press the Reset button once. Reset button function: time, day and mode changed to last saved settings (saved after power loss or when exiting program setup; configuration and program settings are unchanged). Notes. Notes. 22 Notes. Thermostat Warranty. Staple your receipt here. Proof of the original purchase date is needed to validate the warranty. For The Period Of: GE Will Replace: One Year Full Replacement of the thermostat which fails From the date of the due to a defect in materials or workmanship. original purchase What GE Will Not Cover: ¦ Service trips to your location. ¦ Improper installation. If you have an installation problem, contact your installer. You are responsible for providing adequate electrical connections to the product. ¦ Failure of the product resulting from modifications to the product or due to unreasonable use, including failure to provide reasonable and necessary maintenance. ¦ In commercial locations, labor necessary to move the unit, after it has been initially installed, to a location where it is accessible for service by an individual technician; or, if the instructions included in this manual have been disregarded. ¦ Replacement of location fuses or the resetting of circuit breakers. ¦ Damage to the product caused by improper power supply voltage, accident, fire, floods or acts of God. ¦ Incidental or consequential damage caused by possible defects with this thermostat. EXCLUSION OF IMPLIED WARRANTIES—Your sole and exclusive remedy is product exchange as provided in this Limited Warranty. Any implied warranties, including the implied warranties of merchantability or fitness for a particular purpose, are limited to one year or the shortest period allowed by law. This warranty is extended to the original purchaser and any succeeding owner for products purchased for use within ...
Questo manuale è adatto anche per i modelli :Termostato - RAK148P1 (558.98 kb)
Termostato - RAK148P1 (558.98 kb)
Termostato - RAK164P1 (558.98 kb)