Facilità d'uso


It offers programmability, stand-alone operation, and robust, optically isolated communications with automation systems, utility control systems, and personal computers. Electrical rating: 24 V; 2 A; 50/60 Hz Maximum current: 2 A on any circuit, 3 A total The following requirements must be observed for installation in Europe: CE 1. This equipment must be installed in accordance with National wiring rules for the country in which it is installed. 2. All product labels, instructions and markings relating to safety must be translated to a language, which is acceptable in the country in which this equipment is to be installed. INSTALLATION Before installing this thermostat: 1. Read all of the Installation Instructions carefully. 2. Read the Owner's Manual carefully. 3. Ensure that this product is suitable for your application. 4. Ensure that wiring complies with all codes and ordinances. 5. Disconnect power to the control transformer to prevent electrical shock and damage to equipment. 6. Select an appropriate location to ensure an accurate temperature reading. Document Number 65I00-1 / Rev B / February, 2010 Copyright . 2008-2010 Home Automation, Inc. All Rights Reserved Location When replacing an existing thermostat, install the RC-1000 in the same location. If the existing location doesn't meet the following criteria, choose a new location to mount the RC-1000. When choosing a location for the thermostat: 1. Ensure that the thermostat is mounted 5 feet above the floor and is at least 2 feet from an outdoor wall. 2. Ensure that the thermostat is located in an area where there is adequate air circulation. 3. Do not mount in the path of direct sunlight or of radiant heat generated by appliances. 4. Do not mount behind an outdoor wall, near a fireplace, or in the path of any air ducts. Removing an existing thermostat 1. Disconnect the power to the control transformer. 2. Remove the cover to the existing thermostat. 3. Disconnect the wires going to each terminal on the thermostat. Label each wire with the letter or number at the terminal. 4. Remove the existing plate or base from the wall. MOUNTING When mounting the RC-1000, grasp the thermostat by the sides, avoiding the keys, and unsnap the base from the face. Holding the base to the wall so that the word "UP" is upright and facing you: 1. Mark the two mounting holes on the wall using a pencil. 2. Drill a hole using a 3/16" bit at each mounting hole marking. 3. Install the two wall anchors supplied. 4. Slide the system wires through the opening in the base. 5. Mount the base to the wall using the two #6 x 1/2" self-tapping screws supplied -See Figure 1. Figure 1 3 Connect each wire to the terminal strip(s) on the thermostat base per the wiring diagram for your system application - See Figures 4 - 7. Form the thermostat wiring so that the cable lies flat between the terminal strip(s) and the center of the base - See Figure 2. If a remote system or temperature sensor is being used with the thermostat, connect the remote system or temperature sensor wiring per the diagram for the application - See Figures 8 - 11. Upon completion of wiring the thermostat, push all excess wiring into the hole in the wall. Plug the hole with the supplied insulating foam to ensure an accurate temperature reading by the thermostat. Align the tabs of the thermostat face with the slots of the thermostat base. Gently push the thermostat face into the thermostat base locking it into place - See Figure 2. Wall Base Slot Tab Temperature Sensor Figure 2 Figure 3 Note: Be sure that the thermostat temperature sensor is standing up, and that it has not been damaged during installation - See Figure 3. TYPICAL WIRING DIAGRAMS Be sure to disconnect the power to the control transformer before removing CAUTION: or installing thermostat. Do not short gas valve, fan, heat relay, or cool relay...even momentarily. Do not attempt to hook up to live circuits. An accidental connection to a component on the thermostat circuit board could cause damage to the thermostat. 24VAC "HOT" 24VAC Common 24VAC CONTROL TRANSMFOMERTHERMOSTAT UP 1 3 (C) (RC) JUMPER 2 For HVAC systems with a single transformer, the metal jumper between Terminal 1 (RC) and Terminal 2 (RH) on the left terminal strip must remain in place. Figure 4 – Thermostat power-up for test or configuration purposes Important Notes: 1. For HVAC systems with a single transformer for heating and cooling, the metal jumper between Terminal 1 (RC) and Terminal 2 (RH) on the left terminal strip must remain in place – See Figure 4. 2. From the factory, the RC-1000 is configured to control a single stage conventional HVAC system. • If the HVAC system is a heat pump or dual fuel heat pump, before operating the thermostat, the “System Type” settings under “System Options” must be configured – See Installation Settings. 3. When configured as a conventional thermostat, by default this thermostat does not turn the fan on with a call for heat. If the furnace requires t...

Questo manuale è adatto anche per i modelli :
Termostato - RC-1000 (310.7 kb)
Termostato - RC-1000 (310.7 kb)

Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie