|
Facilità d'uso
To get to this feature, press [MODE] in chronograph mode to enter DATA mode when the stopwatch has been stopped. Records for different segments can be recalled, read or deleted. Detailed operation in "DATA" mode is described in Data Mode section below.. Chronograph Data Recall Mode Press [RECALL] in Chronograph mode to recall stored split/lap time memories. The mode message will be shown up for one to two seconds as mode message display is enabled. RECALL The split and lap time will be displayed on the upper and the middle line respectively. The lower line shows the current stopwatch counting. During data recall, the fastest lap time will be reviewed first. RECALL FAST {004} 0: 01' 12" 34 SPLIT 0: 00' 01" 60 LAP RUN 0: 03' 06" 52 Then comes the slowest lap time by further pressing of [RECALL]. RECALL SLOW {001} 0: 00' 07" 63 SPLIT 0: 00' 07" 63 LAP RUN 0: 03' 10" 16 Press [RECALL] again to view the average lap time. RECALL AVG {005} 0: 00' 05" 12 LAP RUN 0: 03' 16" 03 Press [RECALL] continually to review all the stored split/lap times. The sequence starts from the last record to the first record when the stopwatch is running and vice versa when the stopwatch has been stopped. RECALL {005} 0: 00' 14" 91 SPLIT 0: 00' 02" 05 LAP RUN 0: 03' 28" 94 [RECALL] RECALL {004} 0: 00' 12" 86 SPLIT 0: 00' 01" 60 LAP RUN 0: 03' 33" 64 [RECALL] RECALL {003} 0: 00' 11" 26 SPLIT 0: 00' 01" 78 LAP RUN 0: 03' 40" 15 [RECALL] RECALL {002} 0: 00' 09" 48 SPLIT 0: 00' 01" 85 LAP RUN 0: 03' 45" 34 [RECALL] RECALL {001} 0: 00' 07" 63 SPLIT 0: 00' 07" 63 LAP RUN 0: 03' 48" 01 After recalling the first record, press [RECALL] once more to exit from Recall mode and go back to chronograph mode. The "RECALL" icon will be OFF. [RECALL] {005} 0: 03' 50" 11 SPLIT 0: 00' 42" 60 LAP RUN 0: 03' 50" 11 During memory recall, you can press either [START], [STOP] or [LAP/SPLIT] to exit from chrono recall mode and jump to the chrono start/stop or lap state respectively. Data Mode (AE760M & AE790M Model only) Press [MODE] until you enter DATA mode The mode message "DATA" will be shown for one to two seconds before the number of free memories is to be shown. FREE 95 LAP You can press [START] to scroll through all segments. The current segment will come first. RECALL {008} 2 0 0 1 SEG {002} 2 - 1 9 A 10: 15' 30 The header consisting of the date/time stamp will be shown. The number of laps in the segment will appear in the upper left while the segment number is displayed in the middle left. If the segment shown is not your desired segment, press [START] to reach the desired segment. The current segment will be accessed first, then it will cycle back to the 1st, then 2nd and so on. When you have found the segment you want, you can press [RECALL] button consecutively to read the lap records from the first to the last lap. RECALL {001} 0: 01' 00" 55 SEG SPLIT {002} 0: 00' 12" 86 LAP 0: 01' 00" 55 RUN As you continue to press [RECALL] during the display of the last lap, you can advance to the next segment by pressing [START], The front page of the segment will be shown. Say the next segment is SEG 1. RECALL {012} 2 0 0 1 SEG {001} 2 - 1 8 A 10: 00' 15 How to delete individual memory segments: Search the desired segment first as described above. During the display of the segment front page, press [RESET] for 2 seconds to activate Delete One function. "DELETE ONE" will be shown in blinking and beep sound will be generated. dELETE OnE A "ready" period of 2 seconds will be counted. At the end of the ready period, all the lap records of the corresponding segment will be erased. And a long beep sound will be heard. Then the display will show the next segment. If you don't want to delete the records, you can press any key to exit from delete ready state before the end of the ready period and resume the display of the segment front page. How to delete all memory segments: Instead of deleting one segment, you can also delete all memory segments. When you enter the Data mode, you see the screen "FREE XXX LAP". Press and hold the [RESET] for 3 seconds.You will hear "Beep, beep, beep" for 3 seconds, then a long "Beep". At this point all data in the memory will be deleted and "DELETE ALL " will show on the display. If you don't want to delete the records, you can press any key to exit "DELETE ALL " state before the end of the ready period and resume the display of the segment front page. dELETE ALL Timer Mode Press [MODE] until you enter the Timer mode. 3 count-down operation modes are available on this stopwatch: -Count down repeat ( CR ) -Count down stop ( CS ) -Count down, then count up ( CU ) The timer is set at the factory to the count-down repeat (CR) mode. At entering timer mode, the mode message "TIMER" will be shown for a second before the timer counting is to be displayed. {000} 0: 00' 00" 0 CR 0: 00' 00" 0 A 12 : 58' 20 The upper line shows the programmable timer value (initially set at 0:00:00:0) while the middle line displays the current timer counting. Tim...
Questo manuale è adatto anche per i modelli :Misuratori di pressione - AE790M (479.82 kb)