Log:
valutazioni - 1, GPA: 3 ( )

Istruzioni per l'uso Omron Healthcare, Modello AUTOMATIC DIGITAL BLOOD PRESSURE MONITOR HEM-703CP

Produttore : Omron Healthcare
File Size : 270.84 kb
File Nome : hem-703cp_-im_eng.pdf
Lingua di insegnamento: en
Vai a scaricare



Facilità d'uso


Keep in mind only a physician can accurately determine safe or unsafe limits of blood pressure This instrument should be used by non-professional persons only to determine measurement of blood pressure, not to make any medical judgement Remember, blood pressure varies during the day 3 . This unit is a precision instrument . avoid rough handling, direct sunlight, high tem- perature/humidity and magnetic field Fold-ing or bending cuff may result in damage to cuff 4 . Do not inflate cuff above 280 mmHg 5 . Do not take unit apart You cannot calibrate unit If you have any difficulties or problems with unit, contact our Service Center 1-800-634-4350 CONTENTS Important 1 Name and Function of Each Part 2 Preparations for Use 3 Instructions for Use 8 When Error Indication Symbols Appear 10 Specifications 11 1 Name and Function of Each Part Main Unit Systolic Bood Pressure Display Diastolic Blood Pressure and Pulse Display Printing Paper Air Jack Paper Cutter MODE Selector Button SPHYG/CLOCK Button SET Button START Button PRINT / PAPER FEED Button Cuff Tab Air Plug Air Tube 2 Preparations for Use 1 How to insert the batteries 1 . Take off the battery cover at the back of the main unit by sliding it in the direction indicated by the arrow symbol Battery Cover 2 . Install 4 “AA” size batteries attached so that the + and -polarities on the batteries correctly match the polarities in the battery compartment 3 . Replace the cover Replacement • When the “Replace Batteries” symbol( ) flashes during measurement, please replace the batteries with the new ones • When the batteries have run down, random numbers may be displayed Points to be careful about whan using the batteries • When replacing the batteries pleasereplace all four batteries at once • Use the same kind of batteries • Take out weak batteries quickly so as to avoid causing damage to the machine • Remove the batteries when the unit is not used for extended periods 3 Preparations for Use 2 How to Set Time and Date 3 Plug in and Turn on 1 When batteries are installed, the display 1 Insert the air plug into the air jack on the shows PM 12:00 left side of the main unit correctly 2 When the MODE button is pressed down, the “month” sign is displayed When the SET button is pressed down, the figure for the month increases Adjust the “month” 3 When the MODE button is pressed down after the “month” has been adjusted, the “day” sign is displayed Adjust the “day” in the same way as the “month” 4 In the same manner select the “hour” and “min ” with the MODE button and set each value with the SET button AM and PM signs are switched in accordance with the “hour” adjsutment 5 Press the MODE button for the last time and return the screen to normal time (hour, min ) display 2 When the SPHYG/CLOCK button is changed to the sphygmomanometer mode, all the LCD symbols are momentarilydisplayed This happens because the unit is running a check on the display and this state lasts for approximately one second Initial Display 3 Once the LCD symbols vanish, the air release indication symbol ( • ) starts flashing Please wait until the ( • ) symbol goes out Air release indication symbol 4 When the preparations necessary before measurement have been completed, the unit emits a series of beeps and finally the “Ready to Measure” symbol ( ¦ ) will be displayed “Ready to Measure” Display 4 Preparations for Use 4 How to Set the Printing Paper Please be sure not to print without inserting printing paper as it will shorten the life span of the printer head 1 Slide the plastic printer cover in the direction indicated by the arrow symbol and remove it from the main unit 2 Peel off the glued edge of the prontlng paper included with the unit, and cut it off to about 2 inches with a pair of scissors, and then shape and cut the edge for easy insertion to the printer as shown in the figure Reverse Inserting Direction Front 3 Press the PRINT/PAPER FEED button while inserting the edge of the printingpaper to the paper feeding slit When the edge of the paper protrudes sufficiently, release the button and stop feeding 4 Insert the printing paper in the installation section, and then attach the cover back to the main unit in such a way that the edgeof the paper protrudes from the cover 5 When the PRINT/PAPER FEED button is pressed while the results of the measurement are shown on the digital display, these results, together with the date and time of measurement are printed out 6 When purchasing printing paper, ask at the shop where you purchased the main unit for further supply Other brands of papermay be used providing the dimensions are smaller than 38mm wide and 20mm in diameter However the printing quality may differ a little 5 Preparations for Use 5 Changing the Printer Ink Though not originally equipped with an ink roller, the HEM-703CP digital blood pressure monitor contains enough printer ink to last about two years when used once a day at normal room temperature When the ink on the print out becomes light ...


Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie