When parts of a Codabar label are presented to the scanner with this feature enabled, the bar code parts will be assembled by the scanner’s software, and the data will be decoded if all bar code proofing requirements are met. START STATE BARCODE Disable Codabar Stitching Enable Codabar Stitching END 5-64 PowerScan® 7000 Linear Imager Codabar — continued Codabar — continued Minimum Reads This feature specifies the minimum number of consecutive times an Codabar label must be decoded before it is accepted as good read. START READS BARCODE Minimum = 1 Read Minimum = 2 Reads Minimum = 3 Reads Minimum = 4 Reads END Product Reference Guide 5-65 Symbologies Code 93 The following options apply to the Code 93 symbology. Disable/Enable Code 93 When this feature is disabled, the scanner will not read Code 93 bar codes. START STATE BARCODE Disable Code 93 Enable Code 93 END 5-66 PowerScan® 7000 Linear Imager Code 93 Code 93 — continued Length Control Fixed Length Decoding — When fixed length decoding is enabled, the scanner will decode a bar code if the label length matches one of the configurable fixed lengths. Variable Length Decoding — When variable length decoding is enabled, the scanner will decode a bar code if the label length falls in the range of the configurable minimum and maximum length. Configuring Fixed Length Decoding: 1. Scan the START bar code. 2. Scan the Fixed Length Decoding bar code. 3. Scan the END bar code. 4. Set Length 1 to the first fixed length by following the Code 93 Length 1, Length 2 Programming Instructions below. 5. Set Length 2 to the second fixed length (or to ‘00’ if there is only one fixed length) by following the Code 93 Length 1, Length 2 Programming Instructions below. Configuring Variable Length Decoding: 1. Scan the START bar code. 2. Scan the Variable Length Decoding bar code. 3. Scan the END bar code. 4. Set Length 1 to the minimum length by following the Code 93 Length 1, Length 2 Programming Instructions below. 5. Set Length 2 to the maximum length by following the Code 93 Length 1, Length 2 Programming Instructions below. Product Reference Guide 5-67 Symbologies Code 93 — continued START MODE BARCODE Variable Length Decoding Fixed Length Decoding END 5-68 PowerScan® 7000 Linear Imager Code 93 Code 93 — continued Code 93 Length 1, Length 2 Programming Instructions 1. Scan the START bar code. 2. Scan either the Set Length 1 or Set Length 2 bar code. 3. Turn to Appendix C, Alpha-Numeric Pad and scan the two digits representing the length in decimal notation. For Code 93 bar codes, only the data characters are included in the length calculations. NOTE 4. Scan the END bar code. SETTING BARCODE Set Length 1 DEFAULT SETTING FOR THIS FEATURE: 01 DEFAULT SETTING FOR THIS FEATURE: 50 decimal Set Length 2 END Product Reference Guide 5-69 Symbologies Code 93 — continued Code 93 Stitching Enables/disables stitching for Code 93 bar codes. When parts of a Code 93 label are presented to the scanner with this feature enabled, the bar code parts will be assembled by the scanner’s software, and the data will be decoded if all bar code proofing requirements are met. START STATE BARCODE Disable Code 93 Stitching Enable Code 93 Stitching END 5-70 PowerScan® 7000 Linear Imager Code 93 Code 93 — continued Minimum Reads This feature specifies the minimum number of consecutive times an Code 93 label must be decoded before it is accepted as good read. START READS BARCODE Minimum = 1 Read Minimum = 2 Reads Minimum = 3 Reads Minimum = 4 Reads END Product Reference Guide 5-71 Symbologies MSI/Plessey The following options apply to the MSI/Plessey symbology. Disable/Enable MSI/Plessey When this feature is disabled, the scanner will not read MSI/Plessey bar codes. Check Digit Verification This feature specifies whether one or two check digits are to be calculated and verified. Check Digit Transmit When this option is enabled, the scanner will transmit one-digit or two- digit check digits, depending upon the setting for check digit verification. 5-72 PowerScan® 7000 Linear Imager MSI/Plessey MSI/Plessey — continued START STATE BARCODE Disable MSI/Plessey Enable MSI/Plessey Disable Check Digit Verification Enable Check Digit Verification 1-Digit Check Digit Verification 2-Digit Check Digit Verification Product Reference Guide 5-73 Symbologies MSI/Plessey — continued START STATE BARCODE Disable Check Digit Transmission Enable Check Digit Transmission END 5-74 PowerScan® 7000 Linear Imager MSI/Plessey MSI/Plessey — continued Length Control Fixed Length Decoding — When fixed length decoding is enabled, the scanner will decode a bar code if the label length matches one of the configurable fixed lengths. Variable Length Decoding — When variable length decoding is enabled, the scanner will decode a bar code if the label length falls in the range of the configurable minimum and maximum length. Configuring Fixed Length Decoding: 1. Scan the START bar code. 2. Scan the Fixed Length Decoding bar code. 3. Scan the END ...