Log:
valutazioni - 3, GPA: 3.7 ( )

Istruzioni per l'uso Toshiba, Modello TEC FDS-50

Produttore : Toshiba
File Size : 2.29 mb
File Nome : b6b5f3b1-a951-4cc3-9d7e-26708d6f09bb.pdf
Lingua di insegnamento: en
Vai a scaricare



Facilità d'uso


This instruction manual provides a description of the functions and handling of this register and should be read carefully to ensure optimum performance. Since every consideration has been given to safety and reliability, there is no danger of damaging the machine by incorrect operation. Please refer to this manual whenever you have any questions concerning the machine. This machine has been manufactured under strict quality control and should give you full satisfaction. However, if the machine is damaged during transit, or there are any unclear points in this manual, please contact your local TEC representative. • The specifications described in this manual may be modified by TEC, if necessary. • Be sure to keep this manual available for future reference. 2. PRECAUTIONS The ECR is a precision machine. Please handle it carefully considering the following guidelines. REMARKS ON THE LOCATION • Place it where no unusual temperature changes are expected. • Place it on a flat and level surface with little dust, humidity, vibration, etc. • Keep it away from water sources. • Do not use it in direct sunlight for a long time. • Ensure proper ventilation so that the machine is not exposed to excessive heat. • Be certain to connect a grounding wire to prevent the generation of static electricity and noise troubles. Never share the same power outlet with many other electric appliances. REMARKS ON OPERATING THE ECR • The keys on the keyboard function with a light touch. Avoid pressing the keys too hard. • Do not handle the machine with wet hands, since this may cause electrical malfunctions and corrosion of parts. • Do not apply thinner, benzine, or other volatile materials to the cabinet or other plastic parts. Such liquids will cause discoloration or deterioration of the cover. If dirty, wipe off with a piece of cloth soaked in a neutral detergent and wrung out thoroughly. • Turn off the power switch when the operations are over for the day. • Ask your TEC representative to provide periodical maintenance to ensure the optimum performance of the machine. • As for other operations, follow the instructions in this manual. - 1 - E01-11005 3. APPEARANCE AND NOMENCLATURE Paper Cover Journal Window Receipt Outlet Validation Slot Ribbon Cover Customer Display Operator Display GT Lock (Master Terminal only) Mode Lock Power Switch Keyboard • Power Switch: The power switch is located on the righthand side of the cabinet. The AC Power is turned on when the switch is pushed to ON, and turned off when the switch is pushed to OFF. -2 - E01-11005 4. CONTROL LOCKS AND MODE SELECTOR KEYS MODE LOCK (POSITION) (FUNCTION) x MGR SET Key NOTE: No indication is marked at the "OFFLINE” position. I t REG Key SET: In this position, the register will allow programming operations. LOCK: The register operations are locked when the Mode Lock is set to this position. Only paper feeding (using the [RF] or [JF] key) is allowed. MA Key REG: Normal cash register operations are carried out in this mode. The operations programmed to require the MGR ‘MGR’ position cannot be performed in Key this position. X: The sale totals can be read and the programmed data can be verified in this position. MGR: This position allows registering of all normal cash register operations to be carried out in the ‘REG’ mode and the operations programmed to require the ‘MGR’ position. (OFFLINE): This position is used, instead of the REG position, to enter sales data when any trouble occurs on the Master Terminal and therefore the terminal cannot communicate with the Central File in the Master Terminal. Z: All the resettable totals and their counters are read and reset in this position. - 3 - E01-11005 REG Key: The REG Key is used by the cashier who operates the register. This key can access the positions of LOCK and REG. MGR Key: The MGR Key is used by the manager or a person authorized by the manager. This key can access the positions of LOCK, REG, X, and MGR. MA Key: The MA Key is used by the manager who will daily supervise the collection of money and the printout of transactions recorded by the register. This key can access the positions of LOCK, REG, X, MGR, OFFLINE, and Z. SET Key: The SET Key is used by the programmer. This key can access the positions of LOCK and SET. All the keys can be removed from the OFF or REG position. GT LOCK (on Master Terminal only) RTR This lock is provided to read or reset the accumulated sales not on a daily basis but on a weekly or monthly basis. GTX Position: GTZ Position: RTR Position: This position can be accessed by the GTX Key or GTZ Key, and allows to issue GTX reports of consolidated data of the terminals connected to the in-line loop. This position can be accessed by the GTZ Key, and allows to issue GTZ reports of consolidated data of the terminals connected to the in-line loop. This position can be accessed by the RTR Key, and allows to operate in-line ...


Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie