The register will not operate unless one of these keys is inserted and set to the corresponding position on the Clerk Locks. Each of the keys may be inserted and pulled out in the neutral position marked with the (point). Push-key Type (Alternative Option, for ten clerks) j_________This type may be installed in place * I 2 I 3, I I 5 I 0£ clerk Locks above, as an ____alternative option. In that case, 1 6.1 7 1 8—I 9TUU ten clerk keys will be installed. Each clerk is assigned to his/her own clerk key (1 through 10). The register will not operate unless one of these keys is pushed to stay down. GT LOCK This lock is provided to read or reset the accumulated sales totals not on the daily but on weekly or monthly basis. GTX Position: This position allows accumulated totals. to read the The GTX key as well as GTZ Key can access this position. GTZ Position: This position allows to read and reset the accumulated totals. The GTZ position, Key only can access this NOTE: When the GT Lock is turned to either the GTX or GTZ position, the Mode Lock position or any Clerk Key ON/OFF condition will be disregarded. DISPLAY The front display is located at the top of the register just above the keyboard. The display has two types of display — numeric display and message descriptors. I*--f R 0 NI DISPLAY-->| PLU DPT RPT AMOUNT DIE t E 3 H 5 6 '1 8 SHORT SLP AIM REG (-) SI TXBL ST TL CG REAR or RE HO tE DISPLAY Numeric Display AMOUNT (8 digits) DPT (2 digits) RPT (1 digit) Displays the numeric data, such as amount, quantity, etc. Displays the code which represents each Department Key. It stays lit when repeating the same department entry. Displays the repeat department entry count. The count is indicated from the second entry on, and only the first digit will be displayed even if the count exceeds nine. PLU (3 digits, commonly used with the DPT and RPT digits) Displays the PLU code when any PLU is entered. It goes out when repeating the same PLU entry. Message Descriptors SLP Lights up when a slip has been properly inserted and set to allow validation. It flashes to require a slip insertion when validation compulsion has been programmed on the transaction key just operated. ALM Lights up with the alarm buzzer to indicate that the last opera- tion or numeric entry has resulted in an error. To clear the error condition, depress the [c] key. REG Lights up when sale items have been registered. (-) Lights up when the IRTN MDSE I , I DOLL DISC I , or any other key that registers a negative amount has been operated. It also lights up when the (STl or one of the total keys has been depressed and the displayed amount is negative. It lights up also when an amount is entered in the 11 Q" mode. SI Lights up when a department or PLU item that has been netted to the S.I. (Selective Itemizer) is entered, or when the ISI/TLI key is operated. TXBL Lights up when a taxable department or PLU is entered. It also lights up with the "ST” Lamp when the I TXBL TLI key is depressed. ST Lights up when the sub-total amount is displayed after the I ST~| key has been depressed. TL Lights up on a finalizing operation with the total amount displayed when finalized without any amount tendered. CG When an amount tendering operation has been performed, this lamp lights up with the change due displayed. SHORT Lights up when the amount tendered is less than the sale total TRF with the shortage amount displayed. Lights up also when all the sale balance are transferred to the new sale balance for post charging. KEYBOARD LAYOUT The following is a typical keyboard layout for the MA-1100-400 series. Since this series is designed to be capable of programming most of the keys to be placed in the desired place on the keyboard, this is merely an examle. Please ask your TEC representative if any other alternative or additional keys must be installed, referring to the description of the "FUNCTION OF EACH KEY" and "OTHER OPTIONAL KEYS" in this manual. —(Key Cover) 1 9 17 25 SET EX 2 10 18 26 TRF R/A 3 U 19 PO SI/TL P0 4 12 20 28 ST CARD 5 13 21 29 TXBL TL MSC TND 6 14 22 30 Chg 7 15 23 31 AT/TL CHK TND 8 16 24 3? RF JF VALI DATE RTN MDSE NS # AMT SI/M PB- @/F0R PB+ PLU PR OPEN LC OPEN IC/VD DOLL DISC %- %+ BTL RTN VND CPN STR CPN c TX/M 7 8 9 4 5 6 1 2 3 0 00 i - 5 - FUNCTION OF EACH KEY ON fl ^__' OFF RECEIPT GS VALI DATE RECEIPT ON/OFF SWITCH This switch has two positions available — 'OFF' position and 'ON' position. When in the ’OFF' position, no receipt is issued from the register and sales are printed on the audit roll only. When the switch is turned to the ’ON’ position, sales are printed on both the receipt roll and audit roll, then a receipt is issued which is automatically cut off and given to the customer. RECEIPT FEED KEY This key is used to advance the receipt roll. It is operated by depressing the key and holding it in that position until the paper h...