|
Facilità d'uso
(Fixed position) 0 F Always enter 0. (Fixed position) 0 G Always enter 0. (Fixed position) 0 H Number of purchases print Allow printing of number of purchases* 0 Disallow it 1 Function selection for tax Job code: 15 * Item: A B C D E F G Always enter 0. Always enter 0. Always enter 0. Always enter 0. Always enter 0. Always enter 0. Tax delete in REG mode availability Selection: (Fixed position) (Fixed position) (Fixed position) (Fixed position) (Fixed position) (Fixed position) Allow tax delete in REG mode* Disallow it Entry: 0 0 0 0 0 0 0 1 H Manual tax entry in REG mode availability Allow manual tax entry in REG mode* Disallow it 0 1 Function selection for UPC codes Job code: 16 * Item: Selection: Entry: A Always enter 0. (Fixed position) 0 B Always enter 0. (Fixed position) 0 C Dept./PLU/UPC codes printing on journal Disallow Dept./PLU/UPC codes printing on journal* 0 Allow it 1 D Dept./PLU/UPC codes printing on receipt Disallow Dept./PLU/UPC codes printing on receipt* 0 Allow it 1 E UPC learning function Allow UPC learning function* 0 Disallow it 1 F Price entry after ISBN or ISSN codes Compulsory price entry* 0 Inhibit price entry 1 G PLU/UPC price look-up at refund entry Allow PLU/UPC price look-up* 0 Disallow it 1 H C/D(check digit) check for UPC codes Disallow C/D check* 0 Allow it 1 Price entry after ISBN or ISSN codes When you set to “compulsory price entry”, the register requires a price entry when an ISBN or ISSN code is entered. When you set to “Inhibit price entry”, ISBN and ISSN codes cannot be entered. Other programming Job code: 61 * Item: Selection: Entry: A Always enter 0. (Fixed position) 0 B Always enter 0. (Fixed position) 0 C 0 Minus dept./PLU/UPC availability Disallow to program minus dept./PLU/UPC Allow it* 1 D Fractional treatment Round off (4 down, 5 up)* 0 Raising to unit 1 Disregarding fractional treatment 2 E Use of :key Use :key as 00 key* 0 Use :key as 000 key 1 F Time format Use 12-hour format* 0 Use 24-hour format 1 G Date format Use month-day-year format* 0 Use day-month-year format 1 Use year-month-day format 2 H Position of decimal point (from right) (TAB) 0 to 3 (default 2) Job code: 62 * Item: Selection: Entry: A Always enter 0. (Fixed position) 0 B Error beep activation By lock error* 0 By misoperation 1 C Key touch sound availability Allow to sound* 0 Disallow it 1 D Buffered keyboard Yes* 0 No 1 E Void mode operation availability Allow void mode operation* 0 Disallow it 1 F Void mode entry data print in Z2 reports Allow printing of void mode entry data in Z2 reports* 0 Disallow it 1 G Void mode entry data print in Z1 reports Allow printing of void mode entry data in Z1 reports* 0 Disallow it 1 H Addition of hourly sales total data in No* 0 void mode Yes 1 Job code: 66 * Item: Selection: Entry: A Printing a receipt after transaction Total only 0 Details* 1 B Amount printing when PLU/UPC Disallow printing* 0 unit price is zero Allow it 1 C Subtotal printing for conversion of Allow printing* 0 deficit Disallow it 1 D Always enter 0. (Fixed position) 0 E Always enter 0. (Fixed position) 0 F Always enter 0. (Fixed position) 0 G Logo message printing on journals Disallow logo message printing on journals* 0 Allow logo message printing on journals 1 H Footer printing Printing footer on all receipts* 0 Printing footer with selected function key at the time of finalization 1 Job code: 70 * Item: Selection: Entry: A Split pricing counting Quantity* 0 Package 1 B Multiplication/split pricing entry availability Allow multiplication entry only* 0 Allow both of multiplication and split pricing 1 C Always enter 0. (Fixed position) 0 D Always enter 0. (Fixed position) 0 E Always enter 0. (Fixed position) 0 F Always enter 0. (Fixed position) 0 G Always enter 0. (Fixed position) 0 H Always enter 0. (Fixed position) 0 3 Various Function Selection Programming 2 The cash register provides various options so you can use the register to suit your sales needs. In this section, you can program the following features (parameters within parentheses indicates default setting): • Power save mode (entering the power save mode after 30 minutes) • Logo message print format (graphic logo only) • High amount lockout (HALO) for cash in drawer (CID) (9999999.99) (sentinel) - When the cash in drawer reaches the amount programmed, the sentinel mark “X” will be displayed at the leftmost position on the lower line of the operator display. • Thermal printer density (standard density) • Online time out setting • Language selection (English) • Training clerk specification (none) - If you specify a clerk code who is trained for use on this cash register, the cash register will go into training mode when the clerk code is registered for sales entries. The sales operations done by the trained clerk do not affect sales totals. For details, refer to TRAINING MODE section. Power save mode s10 @ *ABCD sA * Item: Selection: Entry: A Entering power save mode Yes* 0 when time is displayed No 1 B-D Time(min.) to enteri...
Questo manuale è adatto anche per i modelli :Allestimento di negozi - XE-A406 (1.83 mb)