Invacare product manuals are available at or your dealer. • Refer to the instructions provided with the side rails for the installation procedure. 4.3 Installing the Power Unit Bed Hook 1. Pull out the bed hook on the back of the control unit. 2. Place the control unit on the footboard. If the bed does not have a footboard, place the • control unit on a flat surface, leaving room for the hose to hang down. FIGURE 2 Installing the Power Unit 4.4 Connecting the Hose CAUTION . Ensure that the hose connecting the control unit to the mattress is routed such that it cannot be stepped on, kinked, squeezed or otherwise damaged. Invacare® MA90Z Series Mattresses 16 Part No 1148139 4 OPERATION 1. Locate the hose at the foot end of the mattress. 2. Locate the control unit connector on the right side of the control unit. 3. Perform one of the following: • MA90Z Power Unit - Perform the following steps (Detail “A”): i. Squeeze and hold the tabs on the hose connectors. ii. Insert the hose connectors into the control unit connector. iii. Push the hose connectors onto the control connector until an audible click is heard. • The audible click indicates that the hose connector(s) are properly engaged with the control connectors. • MA95Z Power Unit - Perform the following steps (Detail “B”): i. Lift and hold the connector cover up. ii. Push the hose connector onto the control connector. iii. Ensure the hose connector is flush with the control unit connector. Control Unit DETAIL “A” - MA90Z DETAIL “B” - MA95Z CONNECTOR CONNECTOR Tab MA95Z, MA95ZB42 and MA90Z, MA95ZB48 Hose MA90ZB42 Connector and MA90ZB48 Connector Hose Cover Connector Control Unit Connectors FIGURE 3 Connecting the Hose Part No 1148139 17 Invacare® MA90Z Series Mattresses 4 OPERATION 4.5 Connecting the Power Cord WARNING . DO NOT alter plug to fit a non-conforming outlet. Instead, have an electrician install a properly grounded outlet. Failure to use the correct plug and outlet can result in a potential safety hazard. CAUTION Ensure that the power cord of the control unit is not pinched, or has any objects placed on it, and also ensure it is not located where it can be stepped on or tripped over. 1. Examine the hospital grade power cord supplied with the control unit. 2. Perform one of the following: • If the plug is damaged - Call your supplier for a replacement hospital grade cord. • If the plug is not damaged - Plug the end of the supplied hospital grade power cord into the power outlet on the side of the control unit. 3. Plug the other end of the plug into a properly grounded outlet on the wall. • Once the unit is plugged in, an AMBER LED on the control unit is lit indicating that the system is in STAND BY mode. Invacare® MA90Z Series Mattresses 18 Part No 1148139 4 OPERATION 4.6 Using the Front Panel DETAIL “A” - Turn Angle Button Power Fail LED Low Pressure LED Power Button Turn Button Turn Time Button Firm Button Soft Button Mode (Max Inflate/ Low Air Loss) Button MA90Z POWER UNIT FRONT PANEL Lock/Alarm Button DETAIL “B” - Select Button Hold Button Power Fail LED MA95Z POWER UNIT FRONT PANEL Power Button FIGURE 4 Using the Front Panel Rotation Button Up/Firm Button Down/Soft Button Max Inflate Button Lock/Alarm Button LCD Part No 1148139 19 Invacare® MA90Z Series Mattresses 4 OPERATION Power Button 1. To turn the control unit on or off, press and release the Power button ( ). Once the unit is plugged in, an AMBER LED on the control unit is lit indicating that the system is in STAND BY mode. Once • the Power button is pressed and released, a GREEN LED illuminates indicating that the control unit is on. If the power comes on after a power outage, the control unit will go through its system initialization routine for a few seconds and then resume the desired function. Turn Button (MA90Z Power Unit) 1. Press the Turn button ( ) to select one of three rotation modes or to set the unit to No Turn (Static) mode. The rotation modes are right, left or both and all three modes include alternating pressure therapy. • When No Turn is selected, all of the air cushions are maintained at a constant pressure. Turn Time Button (MA90Z Power Unit) 1. Press the Turn Time button ( ) to select one of four rotation times. • The rotation times are 10, 20, 30 and 60 minutes. Turn Angle Button (MA90Z Power Unit) 1. Press the Turn Angle button ( ) to select one of four rotation angles. • The rotation angles are 1/4, 1/2, 3/4 and full rotation (45°). Invacare® MA90Z Series Mattresses 20 Part No 1148139 4 OPERATION Rotation Button (MA95Z Power Unit) 1. Press the Rotation button ( ) to select Static mode or Alternating Rotation mode. When the LED is on, Alternating Rotation mode has been selected. • In Static mode, the LED is off and all air cushions are maintained at a constant pressure. Select Button (MA95Z Power Unit) 1. Press the Select button ( )to move the pointer on the LCD to Function. 2. Press the Firm or Soft button until the desired function displays. Ava...
Questo manuale è adatto anche per i modelli :Gear Viaggi - MA95Z (2.22 mb)