|
da questo dispositivo ha anche altre istruzioni :
Facilità d'uso
DS2300 / DS2405
Figure 2: Disk Drive LEDs
B
A
A
B
Note The green Activity LED (A in Figure 2) should be on while the disk spins up and then turn off. The
green Activity LED (A) will blink with I/O activity to the disk. An amber light (B in Figure 2) that is on
briefly when a component first comes on is normal. If this light stays on more than a couple of seconds, a
fault has been detected. See Table 2 for a full list of disk LED behaviors.
If you observe different results, further Troubleshooting may need to be carried out. (See Chapter 4 of
the
HP StorageWorks Disk System 2300 User’s Guide or HP StorageWorks Disk System 2405 User’s Guide
for troubleshooting procedures.)
Table 2: DS2300 / DS2405 Disk Drive LEDs Status Indications
A
B
Disk
Disk Fault
Indication
Activity
(Amber**)
(Green*)
ON
OFF
Installed and spinning up. If the LED is still on 3 minutes
after power is engaged, the disk may be faulty.
Flashing
OFF
Disk drive self-test in progress or there is input/output
activity to the disk.
OFF
ON
Disk drive fault (Controlled by host software).
ON/OFF
Flashing
Host is identifying the disk drive. (Controlled by the host
software).
OFF
OFF
Disk drive not installed or not operating.
*Controlled by the disk drive.
**Controlled by the host software.
... Questo manuale è adatto anche per i modelli :
dati dispositivi di elaborazione - Disk System 2300 Factory Rackable Disk Integration (93.57 kb)
dati dispositivi di elaborazione - Disk System 2300 Factory Rackable SEP Integration (93.57 kb)
dati dispositivi di elaborazione - Disk System 2300 Field Rackable Disk Integration (93.57 kb)
dati dispositivi di elaborazione - HP StorageWorks Disk System 2405 (fctry rcked) (93.57 kb)