Log:
valutazioni - 0, GPA: 0 ( )

Istruzioni per l'uso HP, Modello HP MSA60 Array

Produttore : HP
File Size : 70.93 kb
File Nome :
Lingua di insegnamento: en
Vai a scaricare



da questo dispositivo ha anche altre istruzioni :

Facilità d'uso




HP StorageWorks 6X/7X
About this document
Series Modular Storage
This document details procedures for replacing a failed I/O
module in an HP StorageWorks 6X/7X Series Modular Smart
Array Enclosure.
Array Enclosure
Before you begin
I/O module replacement
CAUTION: Before removing the failed component, make sure
that you have the replacement part available. Removing a
instructions
component impacts the airflow and cooling ability of the
device.

To prevent improper cooling and thermal damage, do not
For updates, visit the HP website for the appropriate enclosure:
operate the enclosure unless all bays are populated with either
MSA60 or MSA70.
a component or a blank.

Do not remove more than one component or blank from the

enclosure at a time. Doing so impacts the airflow and cooling
ability of the device. To avoid possible overheating, insert the
new or replacement component as quickly as possible. If the
internal temperature exceeds acceptable limits, the enclosure
may overheat and automatically shut down or restart.

Parts can be damaged by electrostatic discharge. Use proper
anti-static protection.



Verifying component failure

Use the following methods to verify component failure:




Check the I/O status LED:


Green = System activity

Amber = Fault condition

Off = No system activity


Check the host log for errors.

Removing the I/O module

1.


Power down the enclosure:
a. Power down any attached servers. See the server

documentation.

b. Press the Power On/Standby button on the enclosure.

c. Wait for the system power LED to go from green to
amber.

d. Disconnect the power cords.

2. Disconnect any SAS cables connected to the I/O module.
© Copyright 2006 Hewlett-Packard Development Company, L.P.
3. Squeeze the lever (1) and pull it down (2).
The information contained herein is subject to change without notice.
4. Slide the I/O module out of the chassis (3).
The only warranties for HP products and services are set forth in the
express warranty statements accompanying such products and services.
Nothing herein should be construed as constituting an additional
warranty. HP shall not be liable for technical or editorial errors or
omissions contained herein.
Part number: 436502-001
First edition: November 2006
*436502-001*


...

Questo manuale è adatto anche per i modelli :
dati dispositivi di elaborazione - HP MSA60 Dual Domain (12) 1TB 3.5-inch DP SAS MDL HDD 12TB Bundle (70.93 kb)
dati dispositivi di elaborazione - HP MSA60 Dual Domain (12) 450GB 3.5-inch DP SAS HDD 5.4TB Bundle (70.93 kb)
dati dispositivi di elaborazione - HP MSA70 Array (70.93 kb)
dati dispositivi di elaborazione - HP MSA70 Dual Domain (25) 300GB 2.5-inch DP SAS HDD 7.5TB Bundle (70.93 kb)

Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie