Log:
valutazioni - 0, GPA: 0 ( )

Istruzioni per l'uso HP, Modello HP EVA3000 Disk Array

Produttore : HP
File Size : 159.96 kb
File Nome :
Lingua di insegnamento: en
Vai a scaricare



da questo dispositivo ha anche altre istruzioni :

Facilità d'uso


Operating constraints
This section identifies operating constraints specific to the EVA3000/5000 hardware and VCS software.
Operating constraints for related software applications are included in the following documents:
HP OpenView Storage Management Appliance Software release notes
HP StorageWorks Command View EVA 4.1 release notes
HP StorageWorks Continuous Access EVA 2.2 release notes
HP StorageWorks Business Copy EVA 3.1 release notes
HP StorageWorks Replication Solution Manager 1.2 release notes
Refer to Table 1 for links to the web sites for these products.
Any operating constraints pertaining to the host operating system can be found in the individual operating
system release notes. See "Supported operating system specifications" on page 6.
Upgrading in an HP Continuous Access EVA environment
The following restrictions apply when upgrading to VCS v4.001 on EVA3000/5000 storage systems
running Continuous Access EVA:
• The upgrade process should be completed within one week (168 hours). The time window begins
with the upgrade of the first storage system. It concludes when all storage systems with a direct or
indirect Continuous Access relationship to the first storage system have been upgraded.
• Ensure that all storage systems involved in a DR relationship are fully functional with no failed
hardware.
• When using multiple Continuous Access relationships, make sure the following conditions are met:
• Not more than two VCS versions (either v3.028 or v4.001) are running.
• All EVA 4000/6000/8000 storage systems must be running only one version of XCS (V5.030
or later).
• If you need to update both VCS and XCS, do not attempt to upgrade both simultaneously.
Complete the upgrade one family of firmware before upgrading the other.
• Suspend DR group replication for the duration of the upgrade process on the destination, even if
the intersite links are not available.
• Do not create or delete DR groups or add members or remove members from DR groups when
any storage system in the Continuous Access relationship is still on VCS 3.028 and others are
on VCS v4.001.
A code load of one control er forces both control ers on a storage system to reboot. If the control er being
upgraded is used as a destination for replication I/O, the source controller logs new I/O while the
destination controller reboots. After completing the firmware upgrade of the destination then resume
the replication to allow the controller to perform a merge. Wait for the merge to conclude after a code
load, or wait three minutes—whichever is longer—before performing the code load on any other storage
system in the relationship.
Avoiding problem situations
This section identifies problem situations specific to the EVA3000/5000 hardware and VCS software.
Information for related software applications are included in the documents listed in Operating constraints.
Information on avoiding problem situations specific to operating systems can be found in the individual
operating system connectivity release notes. See "Supported operating system specifications" on page 6.
8


...

Questo manuale è adatto anche per i modelli :
dati dispositivi di elaborazione - HP StorageWorks EVA3000 EMEA Bundles (159.96 kb)

Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie