da questo dispositivo ha anche altre istruzioni :
Facilità d'uso
2.
Run the STORport driver installer from the extracted folder using the default values. For
example:
storportminiportcorekit_2-01a4
This removes the current driver before downgrading to the specified driver version.
•
When using the Smart Component to install drivers, the following message may appear during
reboot:
There was a problem installing this hardware. This device is not
working properly because Windows cannot load the drivers required
for this device. (Code 31)
Uninstall and then reinstall your device.
If the above message appears, click Finish and continue with the reboot procedure. Do not
reply to Microsoft. No known issues have been observed in connection with the display of
this message.
Windows BFS notes
•
In a direct connect environment, BFS fails after a second path is added to an
EVA4000/6000/8000 running firmware 6.110.
•
BFS on c-Class blade servers fails on an active/passive MSA1000/1500 running firmware
5.20.
•
In BFS configurations where there are more than two Emulex HBAs in the same zone as the
boot HBA, a crash-dump may not be generated due to a timeout condition when the boot
HBA interacts with the non-boot HBAs. A workaround is to reconfigure the zoning such that
the boot instance (for each path) is in its own zone separate from the other non-boot HBAs.
In some cases, this also results in faster boot-up times.
•
When installing the OS to attached storage of the 403621-B21 LPe1105 mezzanine card in
a VC environment through a Brocade switch, neither the target LUN nor the WWN for the
boot controller are visible in the zone via the switch administrative tool. The workaround is to
take note of the mezzanine card WWN when installing it into the system, or retrive it from
the VC manager or EFI utility. Then manually enter the WWN into the desired zone on the
switch when configuring the zone. Scan for targets and continue with normal installation steps
to boot from the mezzanine card.
•
In a BFS configuration, the installed HBAs can display different names when viewed through
the device manager. This is a cosmetic condition, not a functional issue.
•
When selecting the Load Driver option during the operating system build of a Windows
2008 server in a BFS configuration, a multiple entry of the Emulex driver is displayed. If
multiple types of HBAs are displayed, select the first entry before proceeding.
•
For more information, see “FCoE BFS build requirement” (page 14).
VMware notes
This section describes information about using VMware and CNAs/HBAs.
OCM GUI on ESX COS servers does not display all SAN storage arrays
The OCM GUI on ESX COS servers does not display all SAN storage arrays due to an issue with
the communication path between the OCM GUI and ESX COS server.
If this occurs, delete the affected server from the host inventory, and then add the server with CIM
credentials (as a CIM server).
16
... Questo manuale è adatto anche per i modelli :
dati dispositivi di elaborazione - HP 81E 8Gb 1-port PCIe Fibre Channel Host Bus Adapter (296.68 kb)
dati dispositivi di elaborazione - HP 81E 8Gb 1-port PCIe Fibre Channel Host Bus Adapter/S-Buy (296.68 kb)
dati dispositivi di elaborazione - HP 81Q 8Gb 1-port PCIe Fibre Channel Host Bus Adapter/S-Buy (296.68 kb)
dati dispositivi di elaborazione - HP 82B 8Gb 2-port PCIe Fibre Channel Host Bus Adapter (296.68 kb)