da questo dispositivo ha anche altre istruzioni :
Facilità d'uso
Table 28 B-series Fibre Channel switch fabric rules (continued)
Rule number
Description
A maximum of 4,096 virtual or physical connections are supported in a fabric containing other switch
models using firmware 6.1.x (or later).
2
8 Gb/s switches and ARB(FF)/ARB(FF) mode setting—HP recommends all 8 Gb/s switches running FOS
6.3.1a and later (6.4.0a and later for XP storage array connectivity) be set to mode 3 using the
portcfgfillword command. For more information, see the Fabric OS Command Reference Manual
supporting Fabric OS v6.4 and the FOS release notes.
Note: HP SN8000B 8-Slot SAN Backbone Director Switch, HP SN8000B 4-Slot SAN Director Switch,
HP StoreFabric SN6500B 16Gb FC Switch, HP SN6000B 16Gb FC Switch, or the HP SN3000B 16Gb
FC Switch automatically selects the proper fill word.
3
HP StorageWorks 4/256 SAN Director—Maximum of 20 chassis per fabric with all 16-port Fibre
Channel blades, maximum of 10 chassis with all 32-port Fibre Channel blades using firmware 5.x (or
later). For all configurations, the maximum number of total virtual or physical connections must not exceed
2,560. Each chassis adds one switch to the fabric switch count if it is configured as one domain. This
switch does not support port-based routing, see "Routing Traffic" in the HP StorageWorks Fabric OS
5.x Administrator's Guide.
4
B-series switches and routers supported routing modes with Continuous Access products:
• HP P9000 (XP) Continuous Access—Supported with port-based routing (aptpolicy = 1) or
exchange-based routing (aptpolicy = 3), see “HP P9000 (XP) Continuous Access FCIP gateway
support” (page 305).
• HP P6000 Continuous Access—Supported with port-based routing (all XCS versions) or exchange-based
routing (XCS 09534000 or later), see “Network requirements for long-distance IP gateways with
XCS 11x, XCS 10x, or XCS 09x” (page 289).
Routing policy—HP recommends that you use the same routing policy in all switches and routers within
a fabric.
5
EVA4400 Embedded Switch Module, 8 Gb Brocade—Supports connectivity to:
• Servers
• Storage
Note: The EVA4400 Embedded Switch Module, 8 Gb Brocade supports the same connectivity to HP
storage systems as the 8/8, 8/24, and 8/80 switches.
• Other B-series switches, including the EVA4400 Embedded Switch Module, 8 Gb Brocade
• MPX200 Multifunction Router with iSCSI (see “MPX200 Multifunction Router with iSCSI for P6000/EVA
storage” (page 323)) and EVA and EVA4400 iSCSI Connectivity Option (see “EVA and EVA4400
iSCSI Connectivity Option ” (page 334))
• MPX200 Multifunction Router with FCIP, HP IP Distance Gateway, and B-series 400 MP Router (see
“HP multi-protocol long-distance products” (page 265))
6
Access Gateway (AG) requirements are:
• AG mode for Brocade 16Gb/16 SAN Switch for HP BladeSystem c-Class requires firmware 7.1.0_blv.
• AG mode for HP SN3000B 16Gb FC Switch requires firmware 7.0.1 (or later).
• AG mode for HP SN6000B 16Gb FC Switch requires firmware 7.0.0a (or later).
• AG mode for Brocade 8Gb SAN Switch for HP BladeSystem c-Class and HP StorageWorks SAN
Switch 8/8 or 8/24 (with 24 ports enabled) requires firmware 6.1x (or later).
• AG mode for the SAN Switch 8/40 requires firmware 6.2x (or later).
• AG mode for the 2408 FCoE Converged Network Switch requires firmware 6.3.1a (or later).
• All switches that communicate with Access Gateway switches require firmware 5.1.x (or later), see
“BladeSystem with Brocade Access Gateway mode” (page 164).
7
In a fabric that contains a StorageWorks SAN Director 4/256, Core switch addressing mode is required
on all other switches in that fabric, see “Core switch addressing mode” (page 115).
8
All B-series Fibre Channel switches and routers must use the HP default setting of dlsSet for
non-Continuous Access configurations and HP P6000 Continuous Access configurations running XCS
104 B-series switches and fabric rules
... Questo manuale è adatto anche per i modelli :
dati dispositivi di elaborazione - HP SAN Solutions (899.67 kb)