Log:
valutazioni - 3, GPA: 4.3 ( )

Istruzioni per l'uso Philips, Modello GC2520

Produttore : Philips
File Size : 739.14 kb
File Nome :
Lingua di insegnamento: enfr
Vai a scaricare



Facilità d'uso


B Steam and boiling water will come out of the soleplate. Impurities and scale (if any) will be flushed out. 9 Use vinegar to remove scale, if any, from the steam control needle (fig. 13). 4 5 6 7 8 Do not bend or damage the steam control needle. 10 Put the steam control back into the iron by inserting the point of the needle exactly in the centre of the hole and by fitting the small projection on the side of the needle into the slot. Press down the steam control while turning it to position O (fig. 14). 11 Repeat the Calc-Clean process if the iron still contains a lot of impurities. After the Calc-Clean process 1 Put the plug in the wall socket and let the iron heat up to allow the soleplate to dry. 2 Unplug the iron when the temperature light has gone out. 3 Move the iron gently over a piece of used cloth to remove any water stains that may have formed on the soleplate. Storage 1 Set the steam control to position O, remove the plug from the wall socket and let the iron cool down. 2 Clean the appliance and wipe scale and any other deposits off the soleplate with a damp cloth and a non-abrasive (liquid) cleaner. Keep the soleplate smooth: avoid hard contact with metal objects. Never use a scouring pad, vinegar or other chemicals. 3 Regurarly rinse the water tank with water and empty it after cleaning (fig. 15). 4 Wind the mains cord round the cord storage facility (fig. 16). 5 Always store the iron standing on its heel in a safe and dry place. Environment . Do not throw the appliance away with the normal household waste at the end of its life, but hand it in at an official collection point for recycling. By doing this you will help to preserve the environment (fig. 17). Guarantee & service If you need information or if you have a problem, please visit the Philips website at or contact the Philips Customer Care Centre in your country (you will find its phone number in the worldwide guarantee leaflet). If there is no Customer Care Centre in your country, turn to your local Philips dealer or contact the Service Department of Philips Domestic Appliances and Personal Care BV. Troubleshooting This chapter summarises the most common problems you could encounter with your iron. If you are unable to solve the problem, please contact the Philips Customer Care Centre in your country. SolutionPossible causeProblem The iron is plugged in but There is a connection Check the mains cord, the the soleplate is cold. problem. plug and the wall socket. The temperature dial has Set the temperature dial been set to MIN. to the required position. No steam. There is not enough water Fill the water tank (see in the water tank. chapter 'Preparing for use', section 'Filling the water tank'). The steam control has Set the steam position to been set to position O. A or E (see chapter 'Using the appliance', section 'Steam ironing'). The soleplate is not hot enough and/or the drip stop function (specific types only) has been activated. Set the temperature dial to a position in the steam area (2 to MAX). Put the iron on its heel and wait until the temperature light has gone out before you start ironing. No shot of steam or no The shot-of-steam Continue ironing in vertical shot of steam function has been used horizontal position and (specific types only). too often within a very wait a while before using short period. the shot-of-steam function again. The soleplate is not hot Set the temperature dial enough. to a position in the steam area (2 to MAX). Put the iron on its heel and wait until the temperature light has gone out before you start ironing. Flakes and impurities come Hard water forms flakes Use the Calc-Clean out of the soleplate during inside the soleplate. function a few times (see ironing. chapter 'Cleaning and maintenance', section 'Calc-Clean function'). The red light blinks The automatic shut-off Pick the iron up or move it (GC2560 only). function has been slightly to deactivate the activated (see chapter automatic shut-off 'Features', section function. The red light 'Automatic shut-off'). stops blinking. There are water droplets The cap of the filling Press onto the cap until on the fabric. opening has not been you hear a click. closed properly. There are water droplets (GC2640/GC2620/ Set the temperature dial on the fabric. GC2530/GC2520 to a position in the steam /GC2510 only).The set area (2 to MAX). Put temperature is too low for the iron on its heel and steam ironing. wait until the temperature light has gone out before you start ironing. Water drips out of the The iron has been put in Empty the water tank and soleplate after the iron has horizontal position while set the steam control to cooled down or has been there was still water in the position O after use. Store stored. water tank. the iron on its heel. FRANCAIS Description generale (fig. 1) A Spray B Bouchon de l'orifice de remplissage C Commande de vapeur -O = pas de vapeur -l = vapeur minimale -; = vapeur maximale -1 = fonction Calc-Clean (ant...

Questo manuale è adatto anche per i modelli :
Ferri - GC2510 (739.14 kb)
Ferri - GC2520/02 (739.11 kb)
Ferri - GC2510/02 (739.11 kb)
Ferri - GC2560/02 (739.11 kb)

Scrivi la tua opinione del dispositivo



Il messaggio
Il tuo nome :
Inserire le due cifre :
capcha





categorie